Pages that link to "ML20236V334"
Jump to navigation
Jump to search
The following pages link to ML20236V334:
Displayed 31 items.
- PNO-III-97-048, on 970516,WI Energy Co & Northern States Power Co Announced They Were Terminating Plans for Proposed Merger of Two Companies Into New Co,Primergy Corp.States of Wi & Mn Will Be Informed of Info in Notification (← links)
- PNO-III-85-057, on 850712,9 Mm Rifle Fired While Being Handled by Security Guard in Auxiliary Bldg.Investigation Continuing.Security Officer Suspended Pending Investigation Results (← links)
- PNO-III-85-043, on 850530,control Rod F-12 Did Not Drop to Bottom of Core During Cold full-flow Control Rod Drop Test. on 850531,rod J-4 Stuck W/Primary Sys at 370 Degrees.Vessel Head Will Be Removed to Determine Why Rods Stuck (← links)
- PNO-III-85-064, on 850725,low Voltage Station Auxiliary Transformer Tripped,Causing Loss of Power to Safeguard Buses.Caused by Wet Pressure Relay (← links)
- PNO-III-80-039, on 800227,unit Shut Down Because of Tube Leakage in Steam Generator A.Leak Rate Was 1420 Gpd.Licensee Will Conduct Eddy Current Tests (← links)
- PNO-III-88-082, on 880919,licensee Suspended Site Access & & Tested for Drugs After Allegation from Outside Source Re Drug Use by Five Employees.Three Employees Tested Positive for Drugs (← links)
- ML20151X965 (← links)
- ML20151X427 (← links)
- PNO-III-97-059, on 970723,util Decided to Delay Planned Startup of Unit 2 to Replace Leaking Seal on B Rcp.Efforts Were Unsuccessful.Unit 1 Remains Shut Down as Util Focused Attention & Resources on Unit 2 Restart (← links)
- PNO-III-98-023, on 980305,unit 2 Completed TS-required Shutdown After Declaring CCW Sys Inoperable.While Shutdown, Licensee Plans to Conduct More Detailed Analysis of Postulated Failure (← links)
- PNO-III-83-112, on 831102-03,airborne Iodine Releases Occurred Inside Containment,During SG Replacement Work. Whole Body Counting Will Be Performed to Evaluate Personal Uptakes.Two Regions Based Specialists Dispatched to Site (← links)
- PNO-III-83-103, on 831021,empty Sf Cast Arrived at West Valley,Ny from Point Beach Nuclear Plant,W/Three Small Areas of Contamination in Excess of Us DOT Limit of 22,000 Disintegrations Per Minute Per 100 Square Centimeters (← links)
- PNO-III-93-050, on 930901,power Supply to Plant Security Sys Failed,Causing Smoke to Fill Battery & Inverter Room. Power Was Restored to Security Sys from Alternate Power Source (← links)
- PNO-III-99-027, on 990514,Unit 1 Was Manually Tripped Due to Steam Leak from 4B Feedwater Heater.Nrc Resident Inspectors Monitored Activities in CR Following Reactor Trip & Monitoring Progress of Repair Work.Licensee Notified NRC (← links)
- PNO-III-97-094, on 971129,unit 1 Reactor Restarted.Unit Scheduled to Remain Online Until Routine Refueling Outage Planned for Early 1998 (← links)
- ML20249B542 (← links)
- ML20249B269 (← links)
- ML20249A174 (← links)
- ML20248L024 (← links)
- ML20248F135 (← links)
- ML20236X042 (← links)
- PNO-III-87-132, on 871007,contract Worker Fainted During Work on Steam Generator B.Slight Contamination to Socks,Face & Hair Noted After Removal of Protective Clothing at Plant Prior to Transport to Hosp.Worker Decontaminated & Examined (← links)
- ML20216K155 (← links)
- PNO-III-97-072, on 970906,shutdown to Correct Potential Undervoltage Condition During Certain Accident Scenarios Occurred.State of Wi Will Be Notified.Info in Preliminary Notification Reviewed W/Licensee Mgt (← links)
- PNO-III-87-084A, on 870618,approx 235 Gallons of Unit 1 Water Discharged Into Lake Michigan Through Unit 2 Svc Water Discharge.Caused by Presence of Entrained Noble Gases. Calculations Verified by Resident Inspectors (← links)
- PNO-III-87-084, on 870619,approx 235 Gallons of Reactor Cooling Water Discharged Into Lake Michigan.Caused by Inadequate Opening of Valve in Letdown Sys.Circumstance of Release Under Review (← links)
- PNO-III-97-067, on 970813,Point Beach Unit 2 Reactor Restarted & on 970816,unit Began Generating Electricity at Ending ten-mouth Outage,Began on 961005.Licensee Issued News Release on Plant Restart.State of Wi Will Be Notified (← links)
- PNO-III-97-017A, on 970218,licensee Decision to Continue Unit 1 Outage for Extended Period Update Made.Nrc Continues to Closely Monitor Licensee Progress Toward Completing Improvement Initiatives & Preparing Units 2 & 1 for Restart (← links)
- PNO-III-97-017, on 970218,Unit Shut Down Because of Possible Problem W/Impeller of CCW Pump & Bearing Problem W/Sw Pump Motor.Unit 2 Shut Down for Refueling & SG Replacement. Resident Inspectors Have Been Monitoring Repair (← links)
- PNO-III-85-043A, on 850530,control Rods F-12 & J-4 Found Stuck During Insp.Caused by Split Pin & Broken Piece of Tube Being Lodged in Guide Tube.Guide Tube Inserts & Internals Will Be Removed & Inspected (← links)
- PNO-III-90-067, on 901003,small Unplanned Release of Noble Gases Occurred While Personnel Collecting Gas Sample from Vol Control Tank.Release Apparently Occurred as Result of Seal Failure on Gas Analyzer Sample Pump (← links)