Pages that link to "05000293/LER-1983-010, Forwards LER 83-010/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000293/LER-1983-010, Forwards LER 83-010/03L-0:
Displayed 32 items.
- 05000293/LER-1983-004, Forwards LER 83-004/03L-0 (← links)
- 05000293/LER-1983-003, Forwards LER 83-003/03L-0 (← links)
- 05000293/LER-1983-007, Forwards LER 83-007/03L-0 (← links)
- 05000293/LER-1983-008, Forwards LER 83-008/03L-0 (← links)
- 05000293/LER-1983-015, Forwards LER 83-015/03L-0 (← links)
- 05000293/LER-1983-020, Telecopy LER 83-020/01X-0:on 830502,daily Surveillance Testing Per Tech Spec Section 4.11.D Not Performed.Caused by Failure to Revise Procedures & Inadvertent Removal of Sections from Tech Specs.Procedures Revised (← links)
- 05000293/LER-1983-013, Forwards LER 83-013/01T-0.Detailed Event Analysis Encl (← links)
- ML20073A226 (redirect page) (← links)
- 05000293/LER-1983-010 (redirect page) (← links)
- 05000293/LER-1983-011, Forwards LER 83-011/03L-0 (← links)
- 05000293/LER-1983-005, Forwards LER 83-005/01T-0 (← links)
- 05000293/LER-1983-010-03, /03L-0:on 830222,two of Four Motor Operator Mounting Cap Screws Found Backed Out of Core Spray Valve MOV 1400-4A.Caused by Sys Vibration.Cap Screws Installed W/Thread Compound Applied.Redundant MOV 1400-4B Inspected (← links)
- 05000293/LER-1983-011-03, /03L-0:on 830225,standby Gas Treatment Sys Filter Train B Found Inoperable Due to Soaked Charcoal.Caused by Incorrect Installation of Alison Control Solenoid Valve 191004.Charcoal Filters Replaced & Fire Watch Established (← links)
- 05000293/LER-1983-032-99, /99X-0:on 830601,organization Changes Made to Station & Corporate Structures in Tech Spec Section 6.2. Changes Intended to Provide More Direct & Effective Support of Station Operations (← links)
- 05000293/LER-1983-029-01, /01T-0:on 830617,spent Fuel Pool a HX E206-A Supports Found Incapable of Withstanding Seismic Loads. Caused by Deviation from Original Design During Initial Const.Supports Modified (← links)
- 05000293/LER-1983-033-03, /03L-0:on 830601,governor for Diesel Generator B Failed to Properly Respond to Control Signals.Caused by Malfunctioning Mechanical Governor Supplied by Woodward Governor Co.Governor Replaced W/Spare (← links)
- 05000293/LER-1983-034-03, /03L-0:on 830606,nitrogen Purge Isolation Valve AO 5033B Failed to Meet Tech Spec Required Closing Time. Caused by Use of 3/8-inch Solenoid Air Supply Valve SV 5033B.Valve Replaced w/1/2-inch Solenoid Valve (← links)
- 05000293/LER-1983-028-03, /03L-0:on 830518,diesel Generator Fuel Booster Pump Belt B Parted.Caused by Broken Belt Clip & Conditions Not Allowing Immediate Replacement of Belt B When Belt a Broken.Belt B Replaced (← links)
- 05000293/LER-1983-001-03, /03L-0:on 830105,inboard Reactor Water Sample Isolation Valve AO-220-44 Did Not Close.Cause Will Be Investigated During Next Outage (← links)
- 05000293/LER-1983-008-03, /03L-0:on 830214,deviation from Tech Spec Fire Barrier Requirements Found During Conversion of Instrumentation & Control Lab to Ofc Space.Caused by Failure to Change Existing Conditions During Retrofit (← links)
- 05000293/LER-1983-009-03, /03L-0:on 830215,during Surveillance,Belt Driven Fuel Pump Broke on Diesel Generator A.Caused by Normal Wear.Belts Replaced (← links)
- 05000293/LER-1983-006-03, /03L-0:on 830212,carbon Samples from One Bank of Standby Gas Treatment Sys a Train Indicated Methyl Iodine Removal Less than Tech Spec Requirement.Probably Caused by Filter Failure.Twelve Filters Replaced in Bank (← links)
- 05000293/LER-1983-004-03, /03L-0:on 830117,reactor Pressure Sys (RPS) Breaker 5 Acb 1A Overheated Causing RPS a to Trip & Initiating Half Scram to Reactor.Caused by High Internal Resistance.Breaker Replaced (← links)
- 05000293/LER-1983-003-03, /03L-0:on 830113,during Surveillance Test,Reactor Water Cleanup Sys High Flow Isolation DPIS-1243 Found Out of Calibr.Caused by Loose Switch Plant Locking Screw Which Allowed Setpoint to Drift.Setpoint Recalibr (← links)
- 05000293/LER-1983-002-01, /01T-0:on 830116,flow Ref off-normal Alarm Received.Average Power Range Monitor Flux Scram Trip Settings Affected.Cause Under Investigation.Flow Inputs Monitored & Amplifier B Recalibr (← links)
- 05000293/LER-1983-002, Forwards LER 83-002/01T-0 (← links)
- 05000293/LER-1983-031-03, /03L-0:on 830528,HPCI Sys Made Inoperable to Repair Steam Leak on AO 2301-31.Caused by Leaking Stem Packing.Packing Replaced.Valve Tested Satisfactorily.Sys Returned to Svc (← links)
- 05000293/LER-1983-027-03, /03L-0:on 830518,during Routine Insp,Folding Fire Door Found Inoperable.Caused by Operating Cable Becoming Detached from Pulley Due to Slack.Cable Reattached & Operating Mechanism Adjusted (← links)
- 05000293/LER-1983-021-03, /03L-0:on 830411,during Surveillance Test 8.7.4.3, Primary Containment Isolation Valve AO-5033B Failed to Meet 10-s Closing Time Requirements.Caused by Lubricant Infiltrating Solenoid Valve Components.Components Replaced (← links)
- 05000293/LER-1983-021, Forwards LER 83-021/03L-0 (← links)
- 05000293/LER-1983-022-03, /03L-0:on 830413,overload on Valve Motor 1301-17 Resulted in Loss of High Pressure Core Cooling Backup Capability.Caused by Oxidation in Motor End Bell & Motor Brushes,Due to Humidity Caused by Leaking Valve Packing (← links)
- 05000293/LER-1983-022, Forwards LER 83-022/03L-0 (← links)