Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000237/LER-1977-004, Regarding Notification from GE That the Maximum Average Planar Linear Heat Regeneration Rate Limits for Dresden 2 and 3 Have Undergone Further Revision, Including Several Reductions + (16:21:46, 8 January 2025)
- 05000237/LER-1978-005, /03L-0 for Dresden Unit 2 Regarding the Receipt of a Torus High/Low Level Alarm as a Result of Torus Level Transmitter Instrument Drift + (16:21:52, 8 January 2025)
- 05000237/LER-1978-009, /01T-0 for Dresden Unit 2 Regarding an Occurrence of a Conductivity Transient Due to Condensate Demineralizer Resin Introduction Into the Rx Vessel + (16:22:00, 8 January 2025)
- 05000237/LER-1977-026, Regarding the Discovery of Pressure Switch PS-263-51A to Activate at 614 PSI + (16:22:02, 8 January 2025)
- 05000237/LER-1977-031, Regarding the Unit 2/3 Make-Up Demineralizer Acid and Caustic Day Tanks Overflowed While Being Filled Simultaneously Due to Operator Error + (16:22:03, 8 January 2025)
- 05000237/LER-1977-028, Regarding Discovery of the Water Tight Buckhead Door Which Provides Flood Protection to the Ccsw Vault to Be Open + (16:22:05, 8 January 2025)
- 05000237/LER-1977-029, Regarding the Control Rod Drives F-5 and H-7 Uncoupling and Overtravelling When Withdrawn to Position 48 Following Testing + (16:22:09, 8 January 2025)
- 05000237/LER-1977-032, Regarding Failure of Motor Operated Suction Valve MO-2-1501-5A to a LPCI to Reopen Remotely from the Control Room + (16:22:13, 8 January 2025)
- 05000237/LER-1977-036, Regarding Failure of the HPCI Motor Speed Changer to Bring the Turbine Speed Above 2800 RPM + (16:22:16, 8 January 2025)
- 05000237/LER-1977-035, Regarding Failure of HPCI 2-2301-8 Mo Valve to Reopen After Completion of Flow Test Surveillance + (16:22:20, 8 January 2025)
- 05000237/LER-1977-034, /03L-0 for Dresden 2 Regarding Main Steam Line Isolation Switch 2-261-16D Initiation of a Group I Isolation Signal on Channel B + (16:22:22, 8 January 2025)
- 05000237/LER-1977-037, /03L-0 for Dresden 2 Regarding the Failure of Recirculation Suction Valve 202-4B to Close from Control Room + (16:22:23, 8 January 2025)
- 05000237/LER-1977-038, /03L-0 for Dresden 2 Regarding Discovery of a Packing Leak on MSIV 203-2B Which Degraded the Primary Containment Boundry + (16:22:28, 8 January 2025)
- 05000237/LER-1977-042, /03L-0 for Dresden 2 Regarding Discovery of Broken Tack Weld on Jet Pump 4 Outboard Restrainer Clamp Bolt Keeper + (16:22:29, 8 January 2025)
- 05000237/LER-1977-048, /01T-0 for Dresden Unit 2 Regarding Indication of Cracking on the CRD Return Line + (16:22:31, 8 January 2025)
- ML17252B372 + (16:22:32, 8 January 2025)
- ML17252B328 + (16:22:33, 8 January 2025)
- ML17252B360 + (16:22:33, 8 January 2025)
- ML17252B321 + (16:22:34, 8 January 2025)
- ML17252B312 + (16:22:35, 8 January 2025)
- ML17252B313 + (16:22:35, 8 January 2025)
- ML17252B311 + (16:22:36, 8 January 2025)
- ML17252B273 + (16:22:36, 8 January 2025)
- ML17252B199 + (16:22:37, 8 January 2025)
- ML17252B198 + (16:22:39, 8 January 2025)
- ML17252B197 + (16:22:41, 8 January 2025)
- 05000249/LER-1980-017, /03L-0 for Dresden Unit 3 Regarding During Refueling Outage, While Conducting Operability Surveillance Test, U-3 Diesel Generator Failed to Start + (16:22:42, 8 January 2025)
- 05000249/LER-1980-021, /01T-0 for Dresden Unit 3 Regarding During Startup Following Refueling Outage, Combinations of 3A Target Rock Valve and 3B, 3C and 3E Electromatic Relief Valves Failed to Open at Rated Reactor Pressure While Performing Operabil + (16:22:43, 8 January 2025)
- 05000237/LER-1980-022, /03L-0 for Dresden Unit 3 Regarding During Normal Shutdown Conditions, IRM 12 Downscale Rod Block Was Found to Trip at 4/125 + (16:22:46, 8 January 2025)
- 05000237/LER-1980-002, /03X-1 for Dresden Unit 3 Regarding During Normal Operation While Performing LPCI Monthly Surveillance, MO-3-1501-118 Valve Would Not Close + (16:22:47, 8 January 2025)
- 05000237/LER-1980-025, /03L-0 for Dresden Unit 3 Regarding During Normal Operation While Performing Main Steam Line High Flow Isolation Surveillance, Flow Switch DPIS 3-261-2A Was Out of Tech. Spec. Limits, Table 3.2.1 + (16:22:49, 8 January 2025)
- 05000237/LER-1980-023, /03L-0 for Dresden Unit 3 Regarding During Normal Operation with Reactor Level Instrument Surveillance in Progress, Level Switch LIS 3-263-58A Tripped at Less than Tech. Spec. Limit of 144 Inches + (16:22:51, 8 January 2025)
- 05000249/LER-1980-030, /03L-0 for Dresden Unit 3 Regarding While Reducing Power for Manual Scram Required by I.E. Bulletin 80-17, Routine Surveillance of MSIV Closure Times Showed That MSIVs 3-203-2B and 2D Closed in Less than 3 Seconds + (16:22:55, 8 January 2025)
- ML17252B187 + (16:22:59, 8 January 2025)
- 05000249/LER-1980-032, /03L-0 for Dresden Unit 3 Regarding During Normal Operations While Performing APRM Rod Block and Scram Functional Tests, APRM 3 Failed to Initiate a Rod Block + (16:23:03, 8 January 2025)
- ML17252B185 + (16:23:09, 8 January 2025)
- 05000249/LER-1980-040, /01T-0 for Dresden Unit 3 Regarding Failure of the HPCI Inboard Steam Supply Valve to Open + (16:23:14, 8 January 2025)
- ML17252B182 + (16:23:15, 8 January 2025)
- ML17252B181 + (16:23:16, 8 January 2025)
- ML17252B180 + (16:23:17, 8 January 2025)
- 05000249/LER-1979-035, /03L-0 for Dresden Unit 3 Regarding Discovery of Valve Mo 3-1501-3A Having No Position Indication + (16:23:18, 8 January 2025)
- 05000249/LER-1980-010, /03L-0 for Dresden Unit 3 Regarding Relief Valves Rv 1105A and 1105B Actuating at 1525 and 1520 PSIG Respectively + (16:23:20, 8 January 2025)
- 05000249/LER-1979-030, /03X-1 for Dresden Unit 3 Regarding a Supplement to LER 79-30/03L-0 Addressing the Cause and Corrective Actions for the Loss of Position Indication for CRD H-9 + (16:23:21, 8 January 2025)
- 05000249/LER-1980-011, /03L-0 for Dresden Unit 3 Regarding Temperature Switch TS 3-261-17B Tripping at 203.1 Degrees Fahrenheit Which Is Above the Technical Specification + (16:23:23, 8 January 2025)
- 05000249/LER-1980-012, /03L-0 for Dresden Unit 3 Regarding Fuel Pool Area ARM Channels a and B Tripping at Levels Exceeding the Technical Specification + (16:23:26, 8 January 2025)
- 05000249/LER-1980-015, /01T-0 for Dresden Unit 3 Regarding Discovery of Reactor Water Cleanup Mechanical Snubber Fully Retracted + (16:23:27, 8 January 2025)
- 05000249/LER-1980-013, /03L-0 for Dresden Unit 3 Regarding B Feedwater Outboard Check Valve 3-220-62B Leakage Exceeding Limit for a Single Isolation Valve + (16:23:29, 8 January 2025)
- ML17252B172 + (16:23:33, 8 January 2025)
- ML17252B167 + (16:23:37, 8 January 2025)
- ML17252B166 + (16:23:38, 8 January 2025)
- ML17252B164 + (16:23:39, 8 January 2025)