Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000382/LER-1995-004-03, :on 950907,discovered Failure to Perform TS SR 4.3.3.6 for RG 1.97 Containment Isolation Valve Position Indicators Due to Inadequate Procedure.Procedure OP-903-013 Will Be Revised + (02:26:58, 26 May 2025)
- 05000315/LER-1984-018-01, :on 840814,CRID IV Inverter Abnormal Alarm Activated Due to Crid Failure,Resulting in Reactor Trip & Safety Injection.Caused by Leaking Water from Emergency Shower & Eyewash Station.Design Change Planned + (02:27:05, 26 May 2025)
- 05000293/LER-1995-009, :on 950821,discovered Surveillance Procedure 8.5.1.3, Core Spray Motor Operated Valve Quarterly Operability Test Not Performed.Caused by Personnel Error. Appropriate Mgt Attention/Action Taken + (02:27:07, 26 May 2025)
- 05000311/LER-1984-020, :on 840813,during Audit of Component Cooling Sys Valve Lineup,Spent Fuel HX Flow Control Valve 2CC37 Discovered Not Locked,Contrary to Tech Specs.Caused by Removal of Valve Lock for Flow Adjustment + (02:27:09, 26 May 2025)
- 05000348/LER-1984-019, :on 840217,during Control Room Insp,Seven Cables in Fire Barrier Penetration Not Sealed Internally. Caused by Procedural Inadequacy.Procedures Revised to Provide Specific Guidance for Installation + (02:27:15, 26 May 2025)
- 05000348/LER-1984-017, :on 840815,main Feedwater Regulating Valve 1A Placed on Manual Jack for Repair of Leaking Diaphragm, Rendering Feedwater Isolation Inoperable.Caused by Air Leak. Diaphragm Replaced + (02:27:16, 26 May 2025)
- 05000348/LER-1984-016, :on 840815,discovered Surveillance Test Procedure for Measuring Stroke Time of Reactor Coolant Drain Tank Discharge Containment Isolation Valve LCV-1003 to Be Inadequate + (02:27:19, 26 May 2025)
- 05000374/LER-1984-052, :on 840817,turbine Received Trip Signal, Producing Reactor Scram.Caused by Voltage Imbalance in Three Phase Y network.Alternator-exciter Replaced + (02:27:26, 26 May 2025)
- TAC:55011 + (02:27:54, 26 May 2025)
- ML20098B073 + (02:28:24, 26 May 2025)
- ML20098B022 + (02:28:34, 26 May 2025)
- ML20098B001 + (02:28:44, 26 May 2025)
- ML20098A998 + (02:28:47, 26 May 2025)
- ML20098A992 + (02:28:50, 26 May 2025)
- 05000255/LER-1995-010, :on 950815,ESFA & Manual RT Occurred Following Isolation of PCS Leak.Caused by Less than Adequate Engagement of Tubing Section Into Compression Fitting. Replaced Failed Instrument Line + (02:31:13, 26 May 2025)
- ML20097H706 + (02:31:53, 26 May 2025)
- NRC-84-0114, Forwards Complete Updated List of as-built Drawings Referenced in Chapter 1 of Snupps Fsar.Bill of Matl for Main Control Panel encl.W/789 Oversize Drawings.Aperture Cards Available in PDR + (02:32:09, 26 May 2025)
- ML20097H128 + (02:32:24, 26 May 2025)
- L-95-050, Technical Evaluation Rept on Second 10-Yr Interval ISI Program Plan:Sce,San Onofre Nuclear Generating Station, Units 2 & 3,Docket Numbers 50-361 & 50-362 + (02:33:50, 26 May 2025)
- 05000311/LER-1981-043-03, /03X-2:on 810612 & 18,pressurizer Overprotection Sys Declared Inoperable Due to Excessive Leakage to Pressurizer Relief tank.Copes-Vulcan 0100-160 Valve Seat Leakage Identified as Generic Problem + (02:34:25, 26 May 2025)
- 05000311/LER-1983-005-03, /03X-1:on 830122,both Channels of Pressurizer Overpressurization Protection Sys Declared Inoperable Due to Leakage in Pressurizer Relief Lines.Porv Plugs Replaced & PORV Circuitry Modified + (02:34:31, 26 May 2025)
- 05000368/LER-1979-086-03, /03X-3:on 791013,shutdown Cooling HX 2E35B Radiational Monitor Indication Increased.Caused by Leak in Tube 74Q.Tube Replaced + (02:34:44, 26 May 2025)
- ML20097E714 + (02:36:11, 26 May 2025)
- ML20097E376 + (02:36:37, 26 May 2025)
- L-96-002, Forwards Revised Monthly Operating Repts for Point Beach Nuclear Plant Units 1 & 2 for Jul,Dec & Mar 1995 + (02:37:18, 26 May 2025)
- EPID:L-2020-TOP-0010 + (02:40:42, 26 May 2025)
- ML20097A843 + (02:41:54, 26 May 2025)
- 05000499/LER-1992-004, :on 920428,TS 3.0.3 Entered Due to Containment Isolation Valves Failing to Close.Cause Not Determined.Ts Change Evaluated to Allow Credit for SG Tubes,Tubesheet & Shell as Isolation Barrier + (02:42:22, 26 May 2025)
- TAC:M75637 + (02:42:25, 26 May 2025)
- 05000311/LER-1982-083-03, /03X-2:on 820812,during Performance of Routine Surveillance,Control Room Operator Received Indication of Low Svc Water Flow on Containment Fan Coil Unit 25.Caused by Oyster Infestation Restricting Svc Water Flow + (02:45:40, 26 May 2025)
- 05000334/LER-1982-048-03, /03L-2:on 821018,during Startup of Main Feed Pump 1B Apparent Overcurrent Condition Detected.Caused by Conservative Transformer Primary Side Overcurrent Relay Setting.Replacement of Relays Planned + (02:46:14, 26 May 2025)
- ML20096F386 + (02:46:48, 26 May 2025)
- ML20096F373 + (02:46:50, 26 May 2025)
- ML20096F314 + (02:46:58, 26 May 2025)
- 05000255/LER-1995-015, :on 951219,determined Up to Twenty MOVs Could Become Unavailable as Result of App R Fire Scenario.Caused by Original App R Review Not Considering Valve Limit Switch Circuits Could Be Routed in Configuration.Valves Repaired + (02:47:45, 26 May 2025)
- L-96-001, Forwards Request for Time Relief from Previously Approved Relief Request VRR-4 + (02:48:01, 26 May 2025)
- 05000456/LER-1995-020-03, :on 951223,TS 3.0.3 Was Entered Due to Having Two Inoperable Power Range Detectors.Replaced & Set Power Supply + (02:48:04, 26 May 2025)
- ML20096E868 + (02:48:08, 26 May 2025)
- 05000334/LER-1995-011, :on 951218,missed Source Range Surveillance Occurred.Caused by Lack of Attention to Detail by Operations Supervisors Controlling Plant Shutdown Procedure.Operations Supervisors Involved Counseled + (02:48:21, 26 May 2025)
- ML20096E704 + (02:48:22, 26 May 2025)
- 05000424/LER-1991-015, :on 910829,leakage Limits Were Exceeded During LLRT of Containment Isolation Valve (Civ).Caused by Manufacturers Casting Mark on Valve Hinge Preventing Closure.Casting Mark on Valve Removed + (02:48:28, 26 May 2025)
- ML20096D717 + (02:49:47, 26 May 2025)
- ML20096D703 + (02:49:49, 26 May 2025)
- ML20096D697 + (02:49:51, 26 May 2025)
- ML20096D515 + (02:50:10, 26 May 2025)
- ML20096D492 + (02:50:12, 26 May 2025)
- ML20096D005 + (02:50:58, 26 May 2025)
- ML20096D004 + (02:50:59, 26 May 2025)
- ML20096D003 + (02:51:01, 26 May 2025)
- ML20096C677 + (02:51:36, 26 May 2025)
- ML20096A997 + (02:54:21, 26 May 2025)