Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19345B033 + (15:32:35, 24 December 2024)
- ML19345B031 + (15:32:36, 24 December 2024)
- ML19345B030 + (15:32:37, 24 December 2024)
- ML19345B028 + (15:32:38, 24 December 2024)
- ML19345B027 + (15:32:39, 24 December 2024)
- ML19345B026 + (15:32:40, 24 December 2024)
- ML19345B025 + (15:32:41, 24 December 2024)
- ML19345B024 + (15:32:42, 24 December 2024)
- ML19345B023 + (15:32:44, 24 December 2024)
- ML19345B022 + (15:32:44, 24 December 2024)
- ML19345B020 + (15:32:45, 24 December 2024)
- ML19345B019 + (15:32:47, 24 December 2024)
- ML19345B018 + (15:32:47, 24 December 2024)
- IR 05000309/1980011 + (15:32:49, 24 December 2024)
- ML19345B014 + (15:32:52, 24 December 2024)
- ML19345B013 + (15:32:53, 24 December 2024)
- IR 05000317/1980014 + (15:32:58, 24 December 2024)
- ML19345B011 + (15:33:00, 24 December 2024)
- ML19345B009 + (15:33:01, 24 December 2024)
- ML19345B007 + (15:33:02, 24 December 2024)
- ML19345B006 + (15:33:03, 24 December 2024)
- ML19345B005 + (15:33:04, 24 December 2024)
- ML19345B003 + (15:33:05, 24 December 2024)
- ML19345B002 + (15:33:08, 24 December 2024)
- ML19345A998 + (15:33:09, 24 December 2024)
- ML19345A997 + (15:33:10, 24 December 2024)
- ML19345A996 + (15:33:11, 24 December 2024)
- ML19345A995 + (15:33:12, 24 December 2024)
- ML19345A994 + (15:33:12, 24 December 2024)
- ML19345A993 + (15:33:13, 24 December 2024)
- 05000249/LER-1980-037-03, /03L-0:on 801020,during Normal Operation W/Dis 500-2 in Progress,Level Switch LIS 263-57B Was Found to Trip at Differential Pressure Less than Tech Specs.Caused by Instrument Drift.Instrument Readjusted + (15:33:15, 24 December 2024)
- 05000320/LER-1980-048-03, /03L-0:on 801017,after Sampling a Core Flood Tank, Inner Containment Isolation Valve CF-V115 Failed to Close. Apparently Caused by Motor & Control Circuits Grounding Out, Induced by Water Leakage.Valve Closed & Deactivated + (15:33:18, 24 December 2024)
- PNO-I-80-168, on 801117,reactor Tripped Due to Low Steam Pressure Signal.Caused by Placing Wrong Channel in Trip When Intermittent Fault Became Evident on Another Instrument. Outage Expected to Last Two Days for Reboration & Repairs + (15:33:21, 24 December 2024)
- 05000320/LER-1980-048, Forwards LER 80-048/03L-0 + (15:33:23, 24 December 2024)
- ML19345A984 + (15:33:24, 24 December 2024)
- PNO-I-80-167, on 800929,State of Nj Dept of Environ Protection Received Ltr from Citizen Complaining of Radioactive Contamination Along Route 17,Rochelle,Park,NJ. Th-232 & Ra-226 Confirmed in 801008 & 20 Soil Samples + (15:33:26, 24 December 2024)
- 05000219/LER-1980-049-01, /01T-0:on 801105,when Isolation Condenser B Was Removed from Svc to Repair Steam Leak,Vent Isolation Valves V-14-1 & V-14-19 Apparently Failed to Close.Cause Undertermined.Stem Packing Replaced & Tested + (15:33:28, 24 December 2024)
- 05000219/LER-1980-049, Forwards LER 80-049/01T-0 + (15:33:29, 24 December 2024)
- ML19345A979 + (15:33:31, 24 December 2024)
- ML19345A978 + (15:33:32, 24 December 2024)
- 05000334/LER-1980-077-01, /01T-0:on 801114,overstress Condition Determined to Exist on Main Steam Line Branch Line Support.Caused by Thermal Movement of Main Steam Line Affecting Branch Line Support.Pipe Support Rod Completed + (15:33:33, 24 December 2024)
- 05000334/LER-1980-077, Forwards LER 80-077/01T-0 + (15:33:35, 24 December 2024)
- ML19345A974 + (15:33:36, 24 December 2024)
- 05000219/LER-1980-048-03, /03L-0:on 801029,during Functional Testing,Snubber 23-7 Failed to Lock Up in Tension Direction.Cause Unknown. Snubber Replaced + (15:33:37, 24 December 2024)
- ML19345A972 + (15:33:38, 24 December 2024)
- ML19345A970 + (15:33:39, 24 December 2024)
- 05000267/LER-1980-067-01, /01T-0:on 801107,tritium Concentration Exceeded Limit Specified in LC04.8.24.8.2(a).Caused by Inadequate Deviation 80-445 to Surveillance Procedure SR 5.8.2bc-M. Procedure & Design Changes Under Investigation + (15:33:43, 24 December 2024)
- 05000219/LER-1980-048, Forwards LER 80-048/03L-0 + (15:33:46, 24 December 2024)
- 05000324/LER-1980-084-03, /03L-0:on 801024,containment Atmosphere Dilution Tank Flow Control Valves 2-CAC-FCV-2717 & 2720 Would Not Operate.Caused by Accumulation of Water in Electropneumatic Converter of Valve 2720.Water Removed + (15:33:48, 24 December 2024)
- 05000267/LER-1980-067, Forwards LER 80-067/01T-0 + (15:33:49, 24 December 2024)
- 05000324/LER-1980-085-03, /03L-0:on 801024,containment Atmosphere Dilution Sys Valves 2-CAD-V55 & 56 Would Not Fully Open.Caused by Deformed Stem Seals in Each Valve Operator.New Stem Seals Installed + (15:33:52, 24 December 2024)