Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20052G716 + (10:36:08, 18 December 2024)
- ML20052G714 + (10:36:08, 18 December 2024)
- ML20052G712 + (10:36:14, 18 December 2024)
- ML20052G711 + (10:36:25, 18 December 2024)
- ML20052G710 + (10:36:26, 18 December 2024)
- ML20052G707 + (10:36:30, 18 December 2024)
- ML20052G705 + (10:36:31, 18 December 2024)
- ML20052G704 + (10:36:43, 18 December 2024)
- ML20052G702 + (10:36:48, 18 December 2024)
- 05000324/LER-1982-075-03, /03L-0:on 820416,during Routine Surveillance, Drywell Floor Drain Flow Integrator 2-G16-FQ-K601 Indicated Continuous Sump Flow W/No Pumps Running.Caused by Operation of Integrator & Square Root Converter Out of Tolerance + (10:36:49, 18 December 2024)
- ML20052G698 + (10:37:02, 18 December 2024)
- 05000324/LER-1982-075, Forwards LER 82-075/03L-0 + (10:37:03, 18 December 2024)
- ML20052G694 + (10:37:04, 18 December 2024)
- ML20052G691 + (10:37:17, 18 December 2024)
- 05000237/LER-1982-010-03, Pilot Cell Voltage Readings Not Taken for 24/48,125 or 250-volt Dc Batteries Per Tech Specs.Caused by Broken Fluke Voltmeter.Event to Be Reviewed W/Shift Supervisors + (10:37:19, 18 December 2024)
- 05000325/LER-1982-043-03, /03L-0:on 820329,exhaust Ventilation Radiation High Instrument 1-D12-RM-N010A Inadvertently Actuated.Caused by Loss of Power Due to Lack of Continuity in Power Supply Output Jumper Plug to Receptacle Connection + (10:37:21, 18 December 2024)
- ML20052G687 + (10:37:24, 18 December 2024)
- 05000321/LER-1982-024-03, /03L-0:on 820414,1P33-N001A,drywell Oxygen Analyzer a Found Out of Calibr.Caused Attributed to Analyzer Drift.Analyzer Recalibr & Returned to Svc.Similar Event Occurred 820415 + (10:37:25, 18 December 2024)
- ML20052G682 + (10:37:30, 18 December 2024)
- ML20052G683 + (10:37:30, 18 December 2024)
- IR 05000546/1982005 + (10:37:46, 18 December 2024)
- 05000369/LER-1982-030-01, /01T-0:on 820423,diesel Generator 1A Declared Inoperable After Failing to Start for Periodic Test.Caused by Failure of Station Design Change Implementation Program to Control Work on Station Mods + (10:37:49, 18 December 2024)
- ML20052G678 + (10:37:50, 18 December 2024)
- ML20052G676 + (10:37:51, 18 December 2024)
- 05000369/LER-1982-030, Forwards LER 82-030/01T-0.Detailed Event Analysis Encl + (10:37:55, 18 December 2024)
- 05000321/LER-1982-024, Forwards LER 82-024/03L-0 + (10:37:57, 18 December 2024)
- ML20052G666 + (10:37:58, 18 December 2024)
- ML20052G664 + (10:38:03, 18 December 2024)
- ML20052G662 + (10:38:04, 18 December 2024)
- ML20052G661 + (10:38:05, 18 December 2024)
- ML20052G660 + (10:38:06, 18 December 2024)
- 05000338/LER-1982-016-03, /03L-0:on 820401,containment Average Temp Exceeded 105 F Due to Loss of Cooling Water to Air Recirculation Cooling Coils.Caused by Loss of Steam Supply to Refrigeration Units Due to Reactor Trip.Supply Restored + (10:38:08, 18 December 2024)
- ML20052G657 + (10:38:09, 18 December 2024)
- ML20052G655 + (10:38:09, 18 December 2024)
- ML20052G653 + (10:38:11, 18 December 2024)
- 05000338/LER-1982-016, Forwards LER 82-016/03L-0 + (10:38:12, 18 December 2024)
- ML20052G648 + (10:38:17, 18 December 2024)
- ML20052G647 + (10:38:18, 18 December 2024)
- 05000325/LER-1982-043, Forwards LER 82-043/03L-0 + (10:38:20, 18 December 2024)
- JAFP-82-0495, Forwards Annual Summary of Plant Mods,Changes & Experiments Implemented During 1981 & 1981-1982 Refueling Outage + (10:38:22, 18 December 2024)
- ML20052G643 + (10:38:24, 18 December 2024)
- ML20052G642 + (10:38:25, 18 December 2024)
- ML20052G640 + (10:38:31, 18 December 2024)
- ML20052G639 + (10:38:32, 18 December 2024)
- ML20052G638 + (10:38:33, 18 December 2024)
- ML20052G635 + (10:38:40, 18 December 2024)
- IR 05000346/1982013 + (10:38:47, 18 December 2024)
- 05000266/LER-1982-010-03, /03L-0:on 820414,ICP 2.9 Found Not to Provide for Proper Unblocking of Source Range High Flux Reactor Trip Over Small Range of Instrument Readings.Caused by Failure to Identify Subtle Procedural Flow.Procedure to Be Revised + (10:38:49, 18 December 2024)
- ML20052G630 + (10:39:01, 18 December 2024)
- 05000266/LER-1982-010, Forwards LER 82-010/03L-0 + (10:39:03, 18 December 2024)
- ML20052G626 + (10:39:10, 18 December 2024)