- ML20066J102 + (16:53:20, 16 December 2024)
- 05000456/LER-1991-001-06, :on 910121,containment Spray Pump 1B Inoperable Due to Nonqualified Power Supply Breaker.Caused by Personnel Error.Breakers Replaced & non-1E Breakers Labeled to Preclude Installation + (16:53:21, 16 December 2024)
- ML20066J099 + (16:53:22, 16 December 2024)
- 05000338/LER-1991-002, :on 910125,two Pressurizer Safety Valves & 7 of 15 Main Steam Safety Valves Foud Outside Setpoint Tolerances Allowed by Tech Specs.Caused by Setpoint Drift.Safety Valves Repaired & Readjusted + (16:53:24, 16 December 2024)
- 05000334/LER-1991-003, :on 910119,two Steam Dump Valves Opened to Condenser,Resulting in Steam Generator Levels Trending Upward & Causing Main Feedwater Containment Isolation.Caused by Subatmospheric Pressure.Procedure Revised + (16:53:26, 16 December 2024)
- 05000334/LER-1991-004, :on 910122,discovered Containment Liner Test Channel Vent Line Unplugged & 11 Plugs Degraded Due to Corrosion.Caused by Failure to Install Plugs During Const. Unplugged Vents Sealed W/Stainless Steel Plugs + (16:53:28, 16 December 2024)
- 05000302/LER-1982-065, Forwards LER 82-065/03L-0 + (16:53:29, 16 December 2024)
- 05000272/LER-1982-080, Forwards LER 82-080/03L-0.Detailed Event Analysis Encl + (16:53:30, 16 December 2024)
- ML20066J093 + (16:53:30, 16 December 2024)
- HL-1476, Monthly Operating Repts for Jan 1991 for Hatch Units 1 & 2 + (16:53:31, 16 December 2024)
- ML20066J087 + (16:53:31, 16 December 2024)
- ML20066J078 + (16:53:32, 16 December 2024)
- 05000325/LER-1982-127-01, /01T-0:on 821103,quick Start Testing of Diesel Generators 2,3 & 4 Not Performed as Required.Caused by Personnel Not Entering Requirement Into Daily Rept.Personnel Instructed + (16:53:34, 16 December 2024)
- JPN-91-007, Forwards Rev 13 to Security Plan,Reflecting Completion of New Warehouse Facility.Rev Withheld (Ref 10CFR73.21 & 2.790(d)(1)) + (16:53:35, 16 December 2024)
- RBG-34-493, Monthly Operating Rept for Jan 1991 for River Bend Station Unit 1 + (16:53:38, 16 December 2024)
- ML20066J061 + (16:53:38, 16 December 2024)
- ML20066J041 + (16:53:40, 16 December 2024)
- 05000311/LER-1982-128, Forwards LER 82-128/01T-0.Detailed Event Analysis Encl + (16:53:41, 16 December 2024)
- 05000339/LER-1982-070-03, /03L-0:on 821025,acoustic Monitor for PORV-2456 Found to Be Inoperable.Caused by Failed Signal from Accelerometer,Originating in Accelerometer or Preamplifier. Active Channel Replaced W/Passibe Channel + (16:53:43, 16 December 2024)
- ML20066J005 + (16:53:44, 16 December 2024)
- 05000339/LER-1982-070, Forwards LER 82-070/03L-0 + (16:53:45, 16 December 2024)
- ML20066J002 + (16:53:45, 16 December 2024)
- ML20066H966 + (16:53:46, 16 December 2024)
- ML20066H932 + (16:53:47, 16 December 2024)
- ML20066H940 + (16:53:47, 16 December 2024)
- ML20066H926 + (16:53:48, 16 December 2024)
- JPN-91-004, Forwards Revised Safety Evaluation Re Proposed Tech Spec Changes to Delete HPCI & RCIC Time Delay Relays,Per + (16:53:49, 16 December 2024)
- ML20066H919 + (16:53:49, 16 December 2024)
- ML20066H915 + (16:53:50, 16 December 2024)
- ML20066H914 + (16:53:51, 16 December 2024)
- NLS9100048, Submits 30-day Followup Rept of Util Investigation Into False Positive Drug Test Results Verbally Reported to NRC Operations Ctr on 901224.Error Due,In Part,To Bypassing Immunoassay Test Portion of Process + (16:53:52, 16 December 2024)
- ML20066H910 + (16:53:52, 16 December 2024)
- ML20066H900 + (16:53:54, 16 December 2024)
- ML20066H894 + (16:53:54, 16 December 2024)
- ML20066H888 + (16:53:55, 16 December 2024)
- ML20066H889 + (16:53:55, 16 December 2024)
- ML20066H887 + (16:53:57, 16 December 2024)
- ML20066H886 + (16:53:58, 16 December 2024)
- 05000373/LER-1990-014-08, :on 901225,electrolyte Temp of 250-volt Battery Found to Be 62 F,Causing Inoperability of RCIC Sys.Caused by Inability of Temp Controller to Maintain Proper Temps. Portable Heaters Placed in Switchgear Room + (16:53:59, 16 December 2024)
- 05000368/LER-1991-001-02, :on 910114,two Through Wall Voids Found.Caused by Breakdown in Communication Between Electrical Maint & Fire Protection Personnel.Rev to Insp Procedures & Improved Training for Insp Personnel Implemented + (16:54:01, 16 December 2024)
- ML20066H879 + (16:54:02, 16 December 2024)
- ML20066H873 + (16:54:03, 16 December 2024)
- 05000416/LER-1982-117-03, /03L-0:on 821020,during shutdown,125-volt Battery Bank Pilot Cell 19 Failed to Meet Tech Spec Min Gravity 1.200.Battery Bank Placed on Equalize Charge for 24-h & Satisfactorily Tested + (16:54:04, 16 December 2024)
- ML20066H846 + (16:54:06, 16 December 2024)
- 05000366/LER-1991-002-01, :on 910130,train a of Standby Gas Treatment Sys Automatically Started & Refueling Floor & Reactor Bldg Ventilation Sys Isolated,Causing ESF Actuations.Caused by Blown Fuse.Failed Relay & Fuse Replaced + (16:54:07, 16 December 2024)
- ML20066H835 + (16:54:10, 16 December 2024)
- 05000416/LER-1982-117, Forwards LER 82-117/03L-0 + (16:54:11, 16 December 2024)
- ML20066H825 + (16:54:13, 16 December 2024)
- ML20066H826 + (16:54:13, 16 December 2024)
- ML20066H823 + (16:54:15, 16 December 2024)
- 05000416/LER-1982-111-99, /99X-0:on 821017,containment Main Steam Tunnel Temp Found in Excess of 125 F.Caused by Low Cooling Water Flow to Tunnel Cooler Due to Partially Open Valve.Valve Lineup Checked & Correct Valve Fully Opened + (16:54:17, 16 December 2024)