Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20069C035 + (16:09:08, 16 December 2024)
- ML20069C031 + (16:09:09, 16 December 2024)
- ML20069C029 + (16:09:09, 16 December 2024)
- ML20069C026 + (16:09:10, 16 December 2024)
- ML20069C027 + (16:09:10, 16 December 2024)
- 05000277/LER-1994-002-03, :on 940426,confirmed That Circulating Water Intake Composite Sampler Sys Not Properly Functioning.Caused by Small Valve on Sys That Became Plugged.Composite Sample Valve & Line Flushed + (16:09:12, 16 December 2024)
- ML20069C024 + (16:09:13, 16 December 2024)
- ML20069C023 + (16:09:14, 16 December 2024)
- ML20069C021 + (16:09:15, 16 December 2024)
- ML20069C022 + (16:09:15, 16 December 2024)
- ML20069C019 + (16:09:16, 16 December 2024)
- 05000254/LER-1983-007-03, /03L-0:on 830214,suppression Chamber Nitrogen Purge Valve AO-1-1601-56 Failed to Isolate During Maint on Drywell High Radiation Monitors.Caused by Failure of Solenoid Pilot Valve.Valve Replaced + (16:09:17, 16 December 2024)
- ML20069C013 + (16:09:18, 16 December 2024)
- ML20069C012 + (16:09:20, 16 December 2024)
- ML20069C011 + (16:09:20, 16 December 2024)
- 05000254/LER-1983-007, Forwards LER 83-007/03L-0 + (16:09:21, 16 December 2024)
- ML20069C008 + (16:09:22, 16 December 2024)
- ML20069C004 + (16:09:23, 16 December 2024)
- ML20069C003 + (16:09:23, 16 December 2024)
- RBG-40590, Responds to NRC Re Notice of Violation & Proposed Imposition of Civil Penalty Described in Insp Repts 50-458/92-15 & 50-458/93-24.Corrective Actions:Safeguards Info Program Transferred from Security to Records Mgt Group + (16:09:24, 16 December 2024)
- ML20069B994 + (16:09:25, 16 December 2024)
- 05000331/LER-1983-005-03, /03L-0:on 830211,river Water Supply Sys Pumps 1P-117B & 1P-117D Declared Inoperative When ASME Allowables Exceeded.Caused by Instrument Error.Instrumentation Will Be Recalbr & Tested Before Startup from Refueling + (16:09:26, 16 December 2024)
- RBG-12-214, Responds to NRC Re Ultimate Capacity Analysis of Mark III Containments. Static Analysis of Containment & Drywell Expected to Be Complete by 820503.Second Analysis Will Not Begin Until Vendor Stress Repts Available + (16:09:29, 16 December 2024)
- ML20069B987 + (16:09:29, 16 December 2024)
- 05000324/LER-1982-013-03, /03L-0:on 820116,reactor Low Level Switch 2-B21-LIS-N07 D-1 Actuated Below Min Level.Caused by Loose Setscrew Allowing Instrument Mechanism to Slip & Prevent Accurate Instrument Response.Screw Tightened + (16:09:31, 16 December 2024)
- ML20069B975 + (16:09:32, 16 December 2024)
- 05000324/LER-1982-013, Forwards LER 82-013/03L-0 + (16:09:33, 16 December 2024)
- ML20069B971 + (16:09:33, 16 December 2024)
- ML20069B970 + (16:09:34, 16 December 2024)
- ML20069B969 + (16:09:35, 16 December 2024)
- ML20069B966 + (16:09:35, 16 December 2024)
- ML20069B965 + (16:09:36, 16 December 2024)
- 05000331/LER-1983-005, Forwards LER 83-005/03L-0 + (16:09:37, 16 December 2024)
- ML20069B961 + (16:09:37, 16 December 2024)
- ML20069B958 + (16:09:38, 16 December 2024)
- ML20069B954 + (16:09:38, 16 December 2024)
- ML20069B951 + (16:09:39, 16 December 2024)
- ML20069B953 + (16:09:39, 16 December 2024)
- 05000302/LER-1982-004-01, /01T-0:on 820129,during Visual Insp of RCP-A Seal Package,Crack in Weld Between Third Stage Cavity & Vent Pipe Discovered.Caused by Crack in Weld Joint Where Vent Pipe Meets Cavity.Rebuilt Spare Seal Package Installed + (16:09:41, 16 December 2024)
- ML20069B944 + (16:09:42, 16 December 2024)
- ML20069B940 + (16:09:44, 16 December 2024)
- ST-HL-AE-4792, Responds to NRC Re Violations Noted in Insp Rept 50-498/94-09.Corrective Actions:Surveillance Test Was Performed & Shift Supervisors Discussed Briefing Item on Lessons Learned with Crews + (16:09:45, 16 December 2024)
- ML20069B931 + (16:09:46, 16 December 2024)
- ML20069B925 + (16:09:47, 16 December 2024)
- ML20069B923 + (16:09:47, 16 December 2024)
- ST-HL-AE-4801, Responds to NRC Re Violations Noted in Insp Rept 50-498/94-12.Corrective actions:mid-loop Procedure Will Be Revised & Lessons Learned Briefings Were Conducted + (16:09:49, 16 December 2024)
- ML20069B915 + (16:09:49, 16 December 2024)
- 05000266/LER-1994-004, :on 940427,unexpected Automatic Trip of Reactor Occurred During Hot Control Rod Drop Testing Due to Inadequate Work Control.Human Performance Root Cause Evaluation 94-016 Being Conducted on Event + (16:09:54, 16 December 2024)
- ML20069B910 + (16:09:57, 16 December 2024)
- ML20069B909 + (16:09:58, 16 December 2024)
- 05000482/LER-1994-004, :on 940426,both Trains of Class 1E HVAC Sys Simultaneously Disabled Due to Inadequate Programmatic Controls.Train a of Class 1E HVAC Sys Restored & Train B of Class 1E HVAC Sys Repaired & Restored + (16:10:00, 16 December 2024)