- 05000366/LER-1982-061, Forwards LER 82-061/03L-0 +
- 05000325/LER-1982-061, Forwards LER 82-061/03L-0 +
- 05000328/LER-1982-061, Forwards LER 82-061/03L-0 +
- 05000317/LER-1982-061, Forwards LER 82-061/03X-0 +
- 05000296/LER-1982-061, Forwards LER 82-061/03L-0 +
- 05000335/LER-1982-061, Forwards LER 82-061/03L-0 +
- 05000311/LER-1982-061, Forwards LER 82-061/03X-1.Detailed Event Analysis Encl +
- 05000369/LER-1982-061, Forwards LER 82-061/03L-0.Detailed Event Analysis Encl +
- 05000373/LER-1982-061, Forwards LER 82-061/03L-0 +
- 05000321/LER-1982-061, Forwards LER 82-061/03L-0 +
- 05000302/LER-1978-061, Forwards LER 78-061/03L-0 +
- 05000395/LER-1982-061, Forwards LER 82-061/03L-0.Detailed Event Analysis Encl +
- 05000331/LER-1982-061, Forwards LER 82-061/03L-0 +
- 05000348/LER-1982-061, Forwards LER 82-061/03L-0 +
- 05000346/LER-1982-061, Forwards LER 82-061/03L-0 +
- 05000339/LER-1982-061, Forwards LER 82-061/03L-0 +
- 05000458/LER-1985-061, Corrected Ltr Forwarding LER 85-061-00.Tracking Number Changed to RBG-23041 +
- 05000304/LER-1978-061, Forwards LER 78-061/03L-0 +
- 05000352/LER-1987-061, :on 871107,subsystems of Control Room Emergency Fresh Air Supply Sys Inoperable.Caused by Personnel Error. Return Fan a Placed in Svc.Personnel Instructed to Review Requirement for Operability +
- 05000424/LER-1987-061, :on 871028,failure to Perform Functional Tests for Safety Injection Pump a & Auxiliary Feedwater Pump Train a Discharge Check Valve Occurred.Caused by Failure to Properly Implement Procedure 10008-C +
- 05000461/LER-1987-061, :on 871014,review of Procedure Identified That Channel Check of Containment Pressure High Trip Function for Containment Spray Missed.Caused by Licensed Operator Error. Personnel Will Be Trained Re Procedures +
- 05000440/LER-1987-061, :on 870830,Tech Specs Violated When Inner Air Lock Door Not Maintained Closed W/Outer Air Lock Door Inoperable.Caused by Bushing Failure.Bushing Replaced & Design Change for Air Lock Door Initiated +
- 05000440/LER-1986-061, :on 860910 & 1002,RWCU Sys Automatically Isolated When Main Steam Line Differential Temp Module Switch Taken to Read. Caused by Fault in Switch Module 1E31-N605A.Temp Switch Modules Scheduled for Replacement +
- 05000482/LER-1986-061, :on 861031,motor Circuit Breaker for Centrifugal Charging Pump a Racked Down,While Charging Pump B Out of Svc.Caused by Personnel Error.Oversight Discussed W/Involved Personnel +
- 05000458/LER-1986-061, :on 861020,cooling Tower Blowdown Radiation Monitor 1RMS-RE108 Experienced Loss of Sample Flow & on 861022,discovered That Grab Samples Required to Be Collected Every 12 H Had Not Been Taken.Test Performed +
- 05000528/LER-1986-061, :on 861119,automatic Actuation of Plant Protection Sys Initiated in Steam Generator 1.Caused by Personnel Error Complicated by Malfunction of Steam Generator 1 Level Channel +
- 05000366/LER-1978-061, Forwards LER 78-061/03L-0 +
- 05000366/LER-1978-061-03, /03L-0 on 781029:during Scram 2-78-14,2B21-NO24A Instru Switch 2 Failed to Actuate at Setpoint 111.6+/-3.6 Inches.Cause:Magnet on 2 Switch Had Metal Shavings on It. Instru Cover Was Loose & Shavings Entered Instru +
- 05000456/LER-1987-061, :on 871224,PORV & PORV Block Valve Stroke Test Surveillance Overdue.Caused by Overly Restrictive Procedural Requirements.Surveillance Procedures Will Be Revised +
- 05000348/LER-1978-061, Forwards LER 78-061/03L-0 +
- 05000316/LER-1978-061-03, /03L-0 on 780802:Rpts While in Hot Standby Above P-11,pressurizer Level Indication Channel 3 Found to Be Different from Other Channels.Caused by Gas Pocket in Sensing Line.(Encl to 7809190315) +
- 05000348/LER-1978-061-03, /03L-0 on 780905:failure of 1-2A Diesel Generator to Respond to Voltage/Speed Control in Auto Due to Failure of Motorized Potentiometer(Failed Diodes)Causing the 125V DC Supply Fuses to Blow +
- 05000315/LER-1985-061, :851116,fire Watch Missed Insp of Fire Hatches, Causing Hourly Tour to Be Late.Caused by Lack of Communication Between Contract Fire Watch & Security Personnel.Personnel Counseled Re Insps +
- 05000341/LER-1985-061, :on 850924,reactor Water Cleanup Sys Isolated. Caused by Incorrect Module Leads Being Lifted,Simulating High Temp Signal.Sys Isolated Again on High Differential Flow Signal Due to Flow Problems +
- 05000325/LER-1985-061, :on 851105,LPCI Mode of Unit RHR Sys & Unit Core Spray Sys Loops a & B Declared Inoperable.Caused by Failure of Permissive Reactor Pressure Transmitter B21-PT-N021A.Transmitter Replaced +
- 05000413/LER-1985-061, :on 851018,unit Shut Down Due to Excessive Unidentified Reactor Coolant Leakage.Caused by Component Failures.Leaking Valves Repaired & Bolts on Neutron Controller Pump Main Flange Retightened +
- 05000454/LER-1985-061, :on 850624,reactor Trip Occurred Due to Steam Generator 1A LO-2 Level.Caused by Attendant Inadvertent Activation of Local Overspeed Trip Bar for Feedwater Pump 1C.Trip Lever Handles Removed +
- 05000528/LER-1985-061, :on 850803,improper Valve Lineup on Radiation Monitor in Fuel Bldg Ventilation Sys Discovered.Caused by Failure of Low Flow Alarm When Valves Placed in Incorrect Configuration.Technicians Counseled +
- 05000373/LER-1985-061-01, :on 850814,diesel Generator 1A Not Run within 1 H of Generator 2A Being Declared Inoperable.Caused by Difficulty in Interpreting Tech Spec Requirements.Diesel Generator 1A Run & Tech Spec 3.8.1 Revised +
- 05000361/LER-1984-061, :on 841022 & 1107 & 08,Train a Containment Purge Isolation Sys (Cpis) Spuriously Actuated.Caused by Induced Electrical Noise Spikes on Containment Area Radiation Monitor 2RT-7856.Setpoint Reset +
- 05000482/LER-1985-061, :on 850914 & 1003,control Room Ventilation Isolation Occurred Due to Chlorine Monitor Signaling High Levels Outside Air Makeup to Sys.Caused by Paper Tape Breakage.Parts in Paper Tape Drive Replaced +
- 05000352/LER-1985-061, :on 850625,inboard Reactor Water Cleanup Isolation Valve Closed as Result of Signal from Temp Switch.Caused by Defective Solder Connection on Internal Component of Temp Switch.Repairs Made +
- 05000483/LER-1984-061, :on 841129,reactor Trip Occurred from 80% Rated Thermal Power Because of Turbine Trip.Load Ctr from 480-volt nonsafety-related Transformer Removed from Svc Tied to Redundant Transformer,Causing Overload +
- 05000373/LER-1984-061-01, :on 841001,combined Leakage of All Four Main Steam Lines Exceeded Tech Spec Limits.Caused by Possible Imperfections in Seating Surfaces.Valves Repaired +
- 05000327/LER-1984-061, :on 840927,RCS Pressurizer Relief Tank Pressure Indicators Had Wrong Pressure Range.Cause Not Stated.Instrument Ranges Will Be Reviewed to Ensure Agreement W/Tech Specs +
- 05000416/LER-1984-061, :on 841228,person Performing Fire Watch Patrol Became Locked in RHR a Piping Room Because Door Handle on Inside of Door 1A204 Broken.Security Will Be Notified by Fire Watch Persons Before Entry Into Area +
- 05000373/LER-1984-061, :on 841001,during Performance of MSIV Local Leak Rate Test,Combined Leakage of All Four Main Steam Lines Exceeded Tech Spec Limits.Caused by Imperfections in Seating Surfaces.Valves Repaired +
- 05000397/LER-1984-061, :on 840614,open Floor Drain Found on 522-ft Elevation of Reactor Bldg.Plant Walkdown Revealed Two Other Drains.Fire Watches Instituted.Drains Will Be Piped Into Floor Drain Sys & Not Sealed as First Planned +
- 05000374/LER-1984-061, :on 840830,reactor Water Cleanup Differential Flow Isolations Occurred.Caused by Density Differences, Lifted Relief Valves & Filter Placed on Line.Investigation Started & Isolation Valves Replaced +
- 05000302/LER-1983-061-03, /03L-0:on 831204,while Performing Control Rod Exercises,Absolute Position Indication for Rod 6,group 2 Failed to Indicate +/- 2% Motion.Caused by Failed Reed Switch.Indicator Tube Will Be Replaced +