- 05000416/LER-1982-186, Forwards LER 82-186/99X-0 + (186)
- 05000327/LER-1983-186-03, /03L-0:on 831209,diesel Generator 1A-A Tripped on High Crankcase Pressure.Caused by Improperly Torqued Wrist Pin Bolts on Cylinder 8.Diesel Repaired.Affected Parts Sent to General Motors Electromotive Div for Insp + (186)
- 05000416/LER-1982-186-99, /99X-0:on 821223,two Fire Doors in Control Bldg Blocked Open to Perform Planned Maint in Control Room.Open Fire Doors Contrary to Tech Spec 3.7.7.Limiting Condition of Operation & Fire Watches Established + (186)
- 05000416/LER-1983-186-03, /03L-0:on 831122,standby Svc Water Pump a Declared Inoperable Due to Low Cooling Water Flow Through Pump. Caused by Sediment in Supply/Return Line Restricting Cooling Flow Through Pump a + (186)
- 05000369/LER-1981-186-03, /03L-0:on 811125,wastewater Treatment Line Radiation Monitor Sample Line Strainer & loss-of-flow Alarm Switch Found Clogged,Inhibiting Radiation Measurement & Alarm.Caused by Orientation of Sample Tap + (186)
- 05000369/LER-1981-186, Forwards LER 81-186/03L-0.Detailed Event Analysis Encl + (186)
- 05000327/LER-1980-186-03, /03L-0:on 801102,during Mode 1,rod Position Indicator E-13,SD Bank A,Became Erratic Then Failed Low. Caused by Defective Connector on Indicator E-13.Spare Connecter F-12 Used Until Defective Connector Repaired + (186)
- 05000327/LER-1980-186, Forwards LER 80-186/03L-0 + (186)
- 05000416/LER-1982-187, Forwards LER 82-187/99X-0 + (187)
- 05000327/LER-1983-187-03, /03L-0:on 831231,two ERCW Radiation Monitors Declared Inoperable.Caused by Failure of Monitor Sample Pump Due to Wear & Tear.Motor Replaced,Checked & Returned to Svc + (187)
- 05000416/LER-1982-187-99, /99X-0:on 821229,smoke Detection Zone Covering Auxiliary Bldg Corridors at 166-ft Elevation Alarmed & Would Not Reset.Caused by Accumulation of Dust in Detector. Detector Cleaned,Functionally Tested & Returned to Svc + (187)
- 05000369/LER-1981-187, Forwards LER 81-187/01T-0.Detailed Event Analysis Encl + (187)
- 05000369/LER-1981-187-01, /01T-0:on 811210,test Curve Data on Replacement Impeller in Centrifugal Charging Pump 1A Indicated Head at Runout Greater than Required.Caused by Failure to Supply Impeller Assembly Specified on 770119 Purchase Requisition + (187)
- 05000327/LER-1980-187, Forwards LER 80-187/03L-0 + (187)
- 05000327/LER-1980-187-03, /03L-0:on 801118,found Vital Instrument Power Board 2-III Being Powered from Maint Power Supply.Caused by Failure of Vital Inverter 2-III.Inverter Restored + (187)
- 05000328/LER-1983-188-03, /03L-0:on 831221,during Attempted Load of Diesel Generator 1A-1,load Dropped Instantly to Zero.Caused by Loose & Dirty Cannon Plug Connector on Engine 1 Governor. Connector Cleaned + (188)
- 05000369/LER-1981-188-01, /01T-0:on 811216,during ESF Actuation Test, Initiate & Reset Switches on a & B Trains Failed.Apparently Caused by Build Up of Chemical Coating on Contacts. Defective Switches to Be Analyzed + (188)
- 05000369/LER-1981-188, Forwards LER 81-188/01T-0.Detailed Event Analysis Encl + (188)
- 05000327/LER-1980-188-03, /03L-0:on 801117,determined That Refueling Water Storage Tank Boron Concentration Was Too High.Caused by Excessive Addition of Boron.Boron Free Makeup Water Added to Restore Boron Concentration to Allowable Limits + (188)
- 05000327/LER-1980-188, Forwards LER 80-188/03L-0 + (188)
- 05000416/LER-1983-189, Updated LER 83-189/03X-1:on 831207 & 840201,breaker 152-1704 to Div 3 ESF Bus Tripped.Caused by Broken Current Limiter Resistor Socket for Breaker Position Indicating Light. Agastat Relay 7012 Replaced + (189)
- 05000328/LER-1983-189-03, /03L-0:on 831224,while in Mode 1,feedwater Flow Channel 2-FT-3-90 Declared Inoperable Due to Frozen Sense Line.Caused by Extreme Low Outside Temp & Blown Fuse in Heat Trace Circuit.Fuse Replaced + (189)
- 05000416/LER-1983-189-03, /03L-0:on 831207,breaker 152-1704 to Div 3 ESF Bus Tripped.Caused by Broken Current Limiter Resistor Socket for Breaker Position Indicating Light.Testing Frequency Will Be Increased to 3 Days + (189)
- 05000369/LER-1981-189, Forwards LER 81-189/03L-0 + (189)
- 05000369/LER-1981-189-03, /03L-0:on 811130,pressurizer Pressure Slowly Decreased & Pressurizer Backup Heaters Violated Tech Specs by Automatically Energizing & Restoring Pressure.Caused by Open Breakers on Heater Power Panels.Extensive Mods Planned + (189)
- 05000327/LER-1980-189-03, /03L-0:on 801119,containment Sump Valve to Containment Spray Pump 1B-B,1-FCV-72-20,failed to Open. Caused by Dirty Contacts on Valve Switch.Contacts Cleaned & Valve Tested + (189)
- 05000327/LER-1980-189, Forwards LER 80-189/03L-0 + (189)
- 05000328/LER-1983-190-03, /03L-0:on 831211,RCS Subcooling Margin Monitor Declared Inoperable Due to Loss of P-250 Computer.Computer Halt Caused by Programmatic Error.Monitor Returned to Svc + (190)
- 05000369/LER-1981-190, Forwards LER 81-190/03L-0 + (190)
- 05000369/LER-1981-190-03, /03L-0:on 811203,lower Personnel Airlock Door on Reactor Bldg Side of Airlock Declared Inoperable Due to Ruptured Seal.Caused by Mfg Design Oversight.Seal Replaced. Procedural Change Should Prevent Similar Failures + (190)
- 05000327/LER-1980-190-03, /03L-0:on 801126,containment Purge Isolation Valves Found Not Leak Rate Tested within 24-h of Stroking. Caused by Delayed Maint Request.Valves Tested within 41-h & Personnel Reinstructed + (190)
- 05000327/LER-1980-190, Forwards LER 80-190/03L-0 + (190)
- 05000328/LER-1983-191-03, /03L-0:on 831227,rod C-11 Declared Inoperable Due to Erratic Behavior.Caused by Faulty Connection at Reactor Vessel Head.Low Current 500-volt Charge Placed on Cable. Rod Returned to Svc + (191)
- 05000416/LER-1983-191-03, /03L-0:on 831217,standby Fresh Air Unit a Placed in Isolated Mode to Meet Tech Spec Action Requirements Due to Planned Div 2 Electrical Outage on 831210.Caused by Operator Error.Procedures Revised + (191)
- 05000369/LER-1981-191-03, /03L-0:on 811215,while in Mod 5, Eight Unsuccessful Attempts Were Made from 811212-17 to Complete Diesel Generator 1B Run.Caused by Leaking Gasket Between Cooling Water Sys & Turbocharger Intercooler.Leak Repaired + (191)
- 05000369/LER-1981-191, Forwards LER 81-191/03L-0 + (191)
- 05000327/LER-1980-191-03, /03L-0:on 801124,component Cooling Water Pump C-S Motor Breaker Failed to Close,Rendering B Train Component Cooling Water Inoperable.Caused by Blown Fuse in Control Circuit.Fuse Replaced + (191)
- 05000327/LER-1980-191, Forwards LER 80-191/03L-0 + (191)
- 05000416/LER-1983-192-03, /03L-0:on 831223,first Shift Failed to Adequately Perform 12 H Channel Check of Tech Spec 4.3.7.1-1.7.Caused by Personnel Error.Daily Operating Log Being Revised + (192)
- 05000369/LER-1981-192-03, Circumferential Butt Welds on ASME Class 1 Piping Previously Identified as Flush Found Potentially Outside ASME Code Criteria.Const Procedures Will Be Revised to Define Profile for Flush Weld + (192)
- 05000369/LER-1981-192, Forwards Updated LER 81-192/03X-1.Detailed Event Analysis Encl + (192)
- 05000327/LER-1980-192-03, /03L-0:on 801201,F14 Control Bank B Rod Position Indicator Deviated by Greater than 12 Steps from Control Bank B Demand Counter.Caused by Shift in Calibr of Control Board Indicator.Indicator Recalibr & Returned to Svc + (192)
- 05000327/LER-1980-192, Forwards LER 80-192/03L-0 + (192)
- 05000416/LER-1983-193-03, /03L-0:on 831227,outboard Suction Valve Closed During Instrument Surveillance.Caused by Tip Breaking Off mini-test Clip.Surveillances Reviewed for Points Requiring Test Connections & Banana Jacks Installed + (193)
- 05000369/LER-1981-193, Forwards LER 81-193/03L-0.Detailed Event Analysis Encl + (193)
- 05000369/LER-1981-193-03, /03L-0:on 811224,technicians Initiated Low Steam Line Pressure Safety Injection Actuation on Both Trains. Caused by Procedural Deficiency.Procedure to Be Corrected by 820122 + (193)
- 05000327/LER-1980-193, Forwards LER 80-193/03L-0 + (193)
- 05000327/LER-1980-193-03, /03L-0:on 801208,review Identified That Channel Functional Test Instruction for Monitors Providing Automatic Termination of Release Did Not Adequately Demonstrate Automatic Isolation.Caused by Inadequate Instruction + (193)
- 05000369/LER-1981-194-03, /03L-0:on 811230,during Periodic Fire Pump Operability Test,Discovered That Fire Pump C Would Not Start.Cause Undetermined.Update Rept Will Be Submitted by 820226 + (194)
- 05000369/LER-1981-194, Forwards LER 81-194/03L-0 + (194)
- 05000327/LER-1980-194-03, /03L-0:on 801201,found Circuit Breaker 7 on 120-volt Vital Instrument Power Board 1-II Tripped,Rendering Radiation Monitors 1-RE-90-112/134/141 Inoperable.Caused by Failure of 0-RE-90-134 Motor.Motor Replaced + (194)
- 05000327/LER-1980-194, Forwards LER 80-194/03L-0 + (194)
- 05000327/LER-1980-195, Forwards LER 80-195/01T-0 + (195)
- 05000327/LER-1980-195-01, /01T-0:on 801212,util Notified That Interlocks on Emergency Feeder Breakers to 6.9-kV Shutdown Boards Could Allow Diesel Generators to Connect to Shutdown Boards W/O Operating Load Stripping Relays & Cause Generator Overload + (195)
- 05000327/LER-1980-196, Forwards LER 80-196/01T-0 + (196)