Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML12093A252 +
- ML19290E886 +
- ML20004F381 +
- L-04-079, May 2004 Monthly Operating Report for Beaver Valley Power Station +
- ML20204H430 +
- ML20211M608 +
- LIC-88-1019, Monthly Operating Rept for Oct 1988 for Fort Calhoun Station +
- ST-HL-AE-3594, Monthly Operating Repts for Sept 1990 for South Texas Project Electric Generating Station Units 1 & 2 +
- 05000285/LER-1988-027, :on 881020,steamfitter Disabled by Heat Exhaustion After Exiting Steam Generator.Caused by Contamination of Protective Clothing.First Aid Provided & Victim Taken to Hosp for Medical Treatment +
- 05000341/LER-1986-020, :on 860715,reactor Protection Sys,Nuclear Steam Supply Shutoff Sys & ECCS Logic Actuated During Inservice Leak Test.Caused by False Initiating Signal +
- 05000353/LER-1996-007-02, :on 961206,manual Scram Occurred Due to Leak in Main Turbine EHC Sys.Caused by Failure of Pressure Switch Support Bracket & Tubing.Replaced Failed Bracket & Tubing & Performed Walkdown of Main Steam Sys +
- 05000285/LER-1976-015-03, /03L:on 760408 & 20,inadvertent Noble Gas Releases to Auxiliary Bldg Occurred Due to Valve leak-by on Chemical & Vol Control Sys.Caused by Leakage by Standby Ion Exchanger CH-8A Isolation Valves +
- 05000272/LER-1981-081-03, /03L-0:on 810827,individual Rod Position Indicators for Control Rods 2A1,1SC1,1C2,1D4 & 2D2 Were in Disagreement W/Demand Position Indicators.Indicators Recalibr & 1SC1 Circuit Card Replaced +
- 05000272/LER-1983-021-03, /03L-0:on 830507,emergency Diesel Generator 1A Tagged Out Due to Broken Differential Current Relay.Caused by Personnel Accidentally Breaking Glass Relay Cover.Relay Cleaned +
- 05000272/LER-1981-042-03, /03L-0:on 810426,Action Statement 3.3.1.1 Was Entered for Pressurize Level Channel 3 Being Inoperable. Channel 3 Was 6% High Relative to Channels 1 & 2.Caused by Packing Leak on Valve 1PS8.Valve Was Repacked +
- ML20041B341 +
- 05000316/LER-2075-005, Letter from Indiana & Michigan Power Co to NRC on Supplement to Abnormal Occurrence of Electrical Blackout Which Occurred on 2/17/1975 +
- 05000281/LER-1990-002-01, :on 900205,two Control Rods of Control Bank D Differed from Rod Group Demand Counter by Greater than 12 Steps.Caused by Inadequate Procedures.Rampdown Stopped & Individual Rod Position Indicators Adjusted +
- 05000272/LER-1981-042, Forwards LER 81-042/03L-0 +
- 05000331/LER-2007-005, Re Automatic Reactor Scram Due to Scram Discharge Volume High Water Level During Performance of a Surveillance Test +
- 05000387/LER-2005-002, TS Required Shutdown Due to Excessive Control Cell Friction +
- 05000254/LER-1992-006, :on 920214,loss of Main Control Room Annunciators Occurred.Caused by Power Surge Due to Lightning Strike Which Caused Fuse Failures.Breakers & Fuses Checked & Replaced as Necessary +