- PLA-4211, Responds to NRC Re Violations Noted in Insp Repts 50-387/94-16 & 50-388/94-16.Corrective Actions:Stand Used to Block Fire Door 44 Removed & Fusible Link Assembly Verified to Hold Door Open +
- ENS 45888 +
- NL-04-152, November 2004 Monthly Operating Report, Indian Point Units 2 and 3 +
- ML20092F425 +
- ML20115C743 +
- ML20078K368 +
- ML20135G249 +
- ML20147E199 +
- ML20206E477 +
- ML20206H490 +
- ML20237K344 +
- ML20235X362 +
- L-99-154, Monthly Operating Repts for Sept 199 for Bvps,Units 1 & 2. with +
- 0CAN089704, Monthly Operating Repts for Jul 1997 for Arkansas Nuclear One +
- ML23089A402 +
- 05000410/LER-2022-002-01, Reactor Protection System Actuation While Shutdown +
- 05000410/LER-2022-002, Reactor Protection System Actuation While Shutdown +
- 05000373/LER-1986-018-02, :on 860504,ESF Damper Actuated When Control Room a HVAC Sys Ammonia Detector OXY-VC125YB Tripped.Caused by Binding of Tape Cassette Spool Mechanism in Detector Unit.Tape Realigned.Alarm Reset +
- 05000254/LER-1997-017-01, :on 970623,Unit 1 Entered 12 Hour Hot Shutdown LCO Inappropriately.Caused by Scheduling Error by Lup.Lups Were Counseled to Avoid Necessary Entry Into 12 H Hot Shutdown LCO +
- 05000338/LER-1986-009-01, :on 860531,reactor Tripped from 100% Power. Caused by Loss of Power to 120-volt Ac Vital Bus (VB) 1-I Due to 480/120-volt Ac Transformer Failure.Power Restored. Transformers Replaced on 860606 +
- 05000461/LER-1999-002, :on 990106,loss of Offsite Power to SR Electrical Buses Was Noted.Caused by Offsite Fault on in Service Offsite Electrical Supply Line.Repairs Were Made to Faulted Line & Leaning Support Structure.With +
- 05000458/LER-1997-008-02, :on 971004,inadvertent Closure of RHR Shutdown Cooling Inboard Isolation Valve Occurred.Caused by Inadequate Administrative Controls,Supervision & Work Practices.Procedures Revised +
- 05000265/LER-1987-013-09, :on 871019,reactor Scram & ECCS Initiations & Related Actuations Occurred.Caused by Personnel Error. Disciplinary Action Administered,Procedures Revised,Training Sessions Held & Circuit Breakers Inspected +
- 05000331/LER-1985-033, :on 850805,emergency Diesel Generator a Removed from Svc for Air Blower Insp.Emergency Diesel Generator B Declared Inoperable Due to High Fuel Oil Sediment Levels. Emergency Diesel Generators Returned to Svc +
- 05000382/LER-1985-027, :on 850626,fire Occurred in Feedwater Pump B at 91% Power.Caused by Small Oil Leak.Fire Extinguished & Oil Reservoir Interconnected Across Top of Baffle Plate on Feedwater Pumps +
- 05000454/LER-1984-043-02, :on 841031,two Seal Injection Header Test Connection valves,1CV066B & 1CV067A,discovered to Be Returned to Svc W/O Required Inservice Insp.Caused by Failure to Follow Procedures.Personnel Trained +
- 05000272/LER-1985-006, :on 850320,containment Sump in-leakage Identified as Svc Water Leak on Containment Fan Coil Unit 13 Motor Cooler.Caused by Leak from Head Gasket.Motor Cooler Replaced.Reported Per IE Bulletin 80-24 +
- 05000374/LER-1984-042-01, :on 840728,rod Sequence Control Sys Declared Inoperable & Reactor Manually Scrammed.Primary Containment Isolation Sys Group I Isolation Also Occurred.Caused by Failure of Pressure Transmitter & Vacuum +
- 05000382/LER-1990-002, :on 900322,reactor Trip Initiated by Plant Protection Sys When Two Control Element Assemblies Dropped to Fully Inserted Position.Caused by Connectors Damaged from Misalignment.Damaged Components Replaced +
- 05000280/LER-1990-019, :on 901218,all Six Main Feedwater Flow Transmitters Found Isolated,Equalized & Drained.Caused by Personnel Error.Policy Re Personnel Responsible for Performing Valve Manipulation Will Be Reviewed +
- 05000389/LER-1987-003-03, :on 870409,during Troubleshooting,Jumper Placed on Wrong Terminal of Main Steam Isolation Signal (MSIS) Actuation Pushbutton Circuitry,Causing Actuation of Msis. Caused by Cognitive Personnel Error +
- 05000354/LER-2004-010, Manual Reactor Scram Due to Moisture Separator Dump Line Failure +
- 05000346/LER-1998-002-01, Regarding Plant Trip Due to High Pressurizer Level as a Result of Loss of Letdown Capability +
- 05000454/LER-1984-043, :on 841031,seal Injection Header Test Connection Valves 1CV066B & 1CV067A Repaired,Replaced & Returned to Svc Prior to Performance of Inservice Insp. Caused by Failure to Follow Procedures +