- JAFP-85-0706, Effluent & Waste Disposal Semiannual Rept,Jan-June 1985 +
- BECO-90-107, Special Rept:On 900803,fire Suppression Sys Diesel Fire Pump Declared Inoperable & Could Not Be Returned to Operable Status within 7 Days.Pump Repaired & Passed Surveillance Test on 900813 +
- 05000324/LER-1989-012-02, :on 890830,emergency Bus E8 Temp high-480 Volt Ground Alarm Annunciation Occurred.Disassembly of Motor Revealed Failure of Windings.Root Cause for Failure Undetermined.Motor Rebuilt & Reinstalled +
- 05000412/LER-1997-011-02, On 971229,determined That Inadequate Electrical Isolation in Secondary Process Rack Circuitry Occurred Due to Design Error.Technical Evaluation Rept 1162 Was Developed +
- ST-HL-AE-2872, Special Rept:On 881027,standby Diesel Generator (Sdg) 13 Tripped When Released from Emergency Mode During Startup. Caused by Nonemergency Mode Shutdown Circuit.Instrumentation Connected to Shutdown Air Header & Restarted +
- 05000254/LER-1986-010, :on 860211,Group II & III Isolations Occurred, During Hfa Relay Replacement.Caused by Personnel Error.Work Packages for Future Hfa Relay Replacements Will Be Written to Prevent Recurrence +
- 05000219/LER-1985-025, :on 851216,inadvertent Automatic Main Steam Line Isolation Occurred During Startup Activities.Caused by Operator Cognitive Error.Operator Training Re Event Will Be Initiated +
- 05000382/LER-1985-027, :on 850626,fire Occurred in Feedwater Pump B at 91% Power.Caused by Small Oil Leak.Fire Extinguished & Oil Reservoir Interconnected Across Top of Baffle Plate on Feedwater Pumps +
- 05000302/LER-1996-017, :on 960531,reactor Tripped on High Reactor Coolant Pressure During Turbine Testing.Caused by Debris in Manual Isolation Valve.Post Trip Analysis Performed & Request for Engineering Assistance Initiated +
- 05000353/LER-1991-003-03, :on 910324,inadvertent Actuation of Reactor Protection Sys Occurred.Caused by Personnel Error.Procedural Guidance Developed,Shift Training Bulletin Issued & Operator Requalification Training Module Revised +
- 05000272/LER-1981-048-03, /03L-0:on 810514,Tech Spec Limit Containment Air Lock Leakage Rate Exceeded Design Pressure During Sp.Caused by Outer Door Seal Not Holding Pressure.Seals Repaired & Tested +
- 05000280/LER-1987-020, :on 870813 & 21,main Control Room Ventilation Isolated.Caused by High Voltage Output on Chlorine Gas Detector CLA-VS-100A.Ventilation Sys Realigned & Verified No Chlorine Gas in Room +
- 05000397/LER-1991-014, :on 910510,RHR Shutdown Cooling Isolation Occurred Due to Less than Adequate Design Drawing Info. Affected Drawings Revised & Tagging Sys to Indicate Sys Interrelationship Updated +
- 05000341/LER-1998-007, :on 980908,inadvertent Deenergization of Safety Buses During Performance of Surveillance Testing Resulted in ESF Actuations.Caused by Faulty Static Underfrequency Relay. Relay Was Removed & Benched Tested +
- 05000324/LER-1998-003-03, :on 980829,MSIV Closures Were Noted.Caused by Procedure Deficiency.Reviewed Lessons Learned from Occurrence with Operations Personnel & Revised Affected Operating Procedures +
- 05000457/LER-1992-006-09, :on 920910,reactor Tripped on low-low SG Level on 2A Sg.Caused by Personnel Error.All Craftpersons Trained on Requirements of Site Work Instruction SWI-14 +
- 05000254/LER-1991-017-01, :on 910904,B Train CR HVAC Emergency Air Filtration Unit Declared Inoperable Due to Equipment Failure & Inappropriate Heater Performance Criteria.Defective Differential Pressure Indicator Replaced +
- 05000346/LER-1990-010, :on 900518,inadvertent Safety Features Actuation W/Injection of 1,000 Gallons Borated Water Occurred W/Plant in Mode 5.Caused by Loss of 120 Volt Ac Bus Y3.Personnel Retrained +
- 05000346/LER-1997-008, :on 970318,inadequate Testing of safety-related Logic Occurred.Overall Root Cause Will Be Completed by 980930 & Results of Evaluation Will Be Reported in Suppl to LER +