- ML19257C280 +
- ML19029B020 +
- ML032390052 +
- ML032320414 +
- ML030230713 +
- ML20077A672 +
- ML20100R284 +
- IR 05000255/1985021 +
- ML20117M209 +
- 05000368/LER-1989-001-01, :on 890503,reactor Protective Sys Instrumentation Declared Inoperable Due to Channel Failing Low Intermittently.Caused by Misinterpretation of Procedure. Procedural Guidance Will Be Issued +
- 05000255/LER-1998-014, :on 981227,control Rod Drive Seal Housing Leak Was Noted.Caused by Transgranular Stress Corrosion Cracking. Faulted Control Rod drive-2 Seal Housing Was Replaced +
- 05000293/LER-1998-024, :on 981015,determined That CR High Efficiency Aire Filtration Sys (Crheafs) Found Outside Design Basis Due to Installation of Duct Tape on Trains a & B Crheafs Supply Fans.Installed Mechanical Seals on Crheafs Supply Fans +
- 05000424/LER-1988-022-01, :on 880714,generator/turbine/reactor Trip Occurred as Result of Overexcitation Condition on Generator Field.Caused by Failure of Potential Transformer Which Led to Circuit Board Failures.Tranformer Replaced +
- 05000373/LER-1985-042-01, :on 850505,high Chlorine/Ammonia Concentration Alarm Received for Control Room/Auxiliary Electrical Equipment Room HVAC Train B.Caused by Faulty Takeup Reel in Ammonia Detector.Detectors Returned to Svc +
- 05000341/LER-1992-008, :on 920919,electrician Did Not Open Bus 65F Trip Cutoff Switch,Resulting in Deenergization of Bus.Caused by Personnel Error.Continuing Training for Operations & Electrical Maint Will Be Emphasized +
- 05000353/LER-1994-001-02, :on 940302,operator Determined That ST Procedure for Unit 2 Isolation Actuation Instrument TU Had Not Been Performed.Cause Was Personnel Error.Shift Supervisor Was Counseled +
- IR 05000324/1982008 +
- 05000373/LER-1990-003, :on 900201,RCIC Isolation Signal Occurred During Warmup.Caused by Spurious High Steam Flow Signal.Rcic Sys Piping Integrity Verified & Isolation Logic Reset.W/ +
- 05000346/LER-2018-001, Borated Water Storage Tank Level Transmitter Out of Tolerance Due to Reaching End of Expected Life +
- 05000296/LER-1995-003-03, :on 950901,DGs Auto Start Occurred Due to Personnel Error During Performance of Common Accident Signal Logic Surveillance.Secured DGs & EECW Pump & Counseled Electricians to Further Emphasize Need to Be More Cautious +
- 05000324/LER-2009-001, Regarding High Pressure Coolant Injection (HPCI) System Inoperable Due to Water in the HPCI Turbine Casing +
- L-99-079, Monthly Operating Repts for Apr 1999 for Beaver Valley Power Station,Units 1 & 2.With +