Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML18152A034 +
- L-14-161, Annual Environmental and Effluent Release Report +
- 05000324/LER-1993-008-02, :on 930714,core Rated Thermal Power Exceeded Allowable Amount Due to Feedwater Flow Inaccuracy.Cause Believed to Be Due to Erosion/Corrosion of FW Flow Elements. FW Instrumentation Recalibr +
- 05000311/LER-1982-032, Forwards LER 82-032/03L-0.Detailed Event Analysis Encl +
- ML040830634 +
- ML20069K106 +
- ML20076K601 +
- ML20133G577 +
- ML20206G177 +
- IR 05000245/1988099 +
- ML20247D145 +
- 05000352/LER-1987-062, :on 871114,reactor Encl Isolation Occurred. Caused by Personnel Error When Operator Changed Operating Lineup of Reactor Encl Ventilation Fans.Operator Counseled & Operator Aid Posted at Exhaust Control Panel +
- 05000413/LER-1998-008, :on 980611,noncompliance W/Ts Requirements for Wgs O Analyzers Was Noted.Caused by Error in Interpretation of TS Requirements.Procedures Revised +
- 05000259/LER-1996-003-03, :on 960403,Unit 2 Received Unplanned ESF Actuation.Caused by Electrician Introduced Fault Into ECCS Logic While Preparing Wires for Termination in Panel 2-9-81. Problem Evaluation Rept Initiated +
- ML20009D892 +
- ML20009D687 +
- ML20141C762 +
- 05000346/LER-1978-064-03, /03L-1:on 780608,radiation Monitor Re 5030 Pump Failed After Large Flow Oscillations Discovered.Caused by High Ambient Temps.Pump Repaired & Ventilation Requested for Cabinet +
- 05000346/LER-1978-067-03, /03L-0:on 780615,power Loss to Decay Heat Pump Caused by Three Acidental de-energizations of Bus D1.Caused by Personnel Errors.Essential Bus D1 re-energized.Operator & Electricians Instructed to Be More Careful +
- 05000281/LER-1988-004, :on 880327,turbine Runback Automatically Initiated Due to Loss of Power to Power Range Nuclear Instrument NI-43.Caused by Internal Conductor Failure Due to Age.Vital Bus Inverters Replaced +
- 05000280/LER-1987-026, :on 871018,main Control Room (MCR) Ventilation Isolated Due to High Voltage Output on Chlorine Gas Detector.Chemistry Verified No Chlorine Gas in MCR & Ventilation Sys Realigned +
- 05000255/LER-2012-002, Technical Specification Required Shutdown Due to Un-isolable Secondary Side Drain Valve Leak +
- 05000382/LER-2008-003, Regarding Movement of Fuel Assembly in Reactor Vessel with Fuel Handling Machine Inoperable +
- 05000346/LER-2003-009, Regarding Loss of Offsite Power Due to Degraded Regional Grid Voltage +
- L-99-079, Monthly Operating Repts for Apr 1999 for Beaver Valley Power Station,Units 1 & 2.With +