Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000254/LER-2002-001 +
- ML17334B395 +
- 05000311/LER-1990-042, :on 901220,SWS Through Wall Leak on Inlet Pipe to Component Cooling Pump Room Cooler Occurred.Caused by Equipment Failure & Internal Corrosion.Carbon Steel Pipe Will Be Painted for Protection +
- ML052780336 +
- RC-05-0095, LER 05-S01-00 for Virgil C. Summer Nuclear Station Entry of Unauthorized Employee Into the Protected Area +
- ML20053C217 +
- IR 05000390/2003005 +
- ML20063G129 +
- ML20100R429 +
- ML20106B479 +
- ML20136G722 +
- ML20136B002 +
- ML20138M116 +
- ML20134L052 +
- ML20133B790 +
- ML20141D162 +
- RBG-30536, NPDES Noncompliance Notification:On 890410 & 11,effluent Limitations for Outfall 004 Exceeded Limits.Caused by Inability to Effectively Adjust Chlorine Dosage W/ Fluctuating Flows & Oxidant Demand +
- ML20125A183 +
- 05000322/LER-1989-006, :on 890707,hydraulic Transient Inadvertently Initiated Which Resulted in Automatic ESF & Reactor Trip. Caused by Personnel Error.Reactor Trip & Analog Trip Alarms Reset.Personnel Involved Counseled +
- 05000413/LER-1987-034, :on 870823,reactor Trip Breakers Opened While Shutting Down Due to Inability to Satisfy RCS Leakage Tech Spec Requirements.Caused by Failure of Source Range Neutron Detector.Hi Flux Reactor Trip Alarm Bypassed +
- 05000331/LER-1985-041, :on 851007 & 28,maint Activities on Isolation & Downstream Valves Required Voluntary Realignment of Fire Suppression Sys from Normal to Backup Water Supply.Sys Returned to Normal Status +
- 05000352/LER-1995-008-01, :on 950911,unusual Event Declared & RPS Actuated When Reactor Manually Shutdown Due to Inadvertent Opening of Ms SRV M.Caused by Pilot Valve Seat Leakage.Srv M & Four Other SRVs Removed & Replaced +
- 05000413/LER-1991-028, :on 911024,Tech Spec Violation Occurred Due to Exceeding Liquid Waste Release Limits as Result of Inappropriate Actions.Chemistry Specialist Counseled.W/ 911120 1tr +
- 05000271/LER-1994-007, :on 940420,SBGTS Initiation & Reactor Building Ventilation Isolation Occurred Concurrent W/Pcis Group III Isolation.Caused by Dirty/Oxidized Contacts on Switch. Corrective Action:Cleaning Switch Contacts +
- 05000285/LER-1990-023, :on 900921,safety Injection Piping & Relief Valves Were Out of Design Basis +
- 05000334/LER-1990-013, :on 900815,control Room Emergency Breathing Air Pressurization Sys Actuated,Pressurizing Common Control Room Envelope.Caused by Erroneous Signal Spike.Monitor Output Signals Disabled +
- 05000440/LER-1993-010, :on 930326,manual Reactor Scram Inserted Due to Rupture in 30 Inch Section of Underground SW Piping.Caused by Pipe Bending Due to Localized Loss of Soil Support. Failed Portion of SW Piping Being Repaired +
- 05000316/LER-1998-005-01, :on 980715,potential for HELB to Degrade Component Cooling Water Sys Was Noted.Investigation & Analysis of Signficance of Event Is Continuing.Method May Be Developed to Protect CCW Pump Area +
- 05000423/LER-2016-003, Regarding Loss of Safety Function-Supplementary Leak Collection and Release System +
- 05000352/LER-1987-013, :on 870508,reactor Encl Secondary Containment Isolated Due to Low Differential Pressure Between Encl & Outside Environ.Caused by Personnel Error.Sign Posted on Filter Entry Hatch +