- ENS 47201 +
- ML120620542 +
- ML12047A372 +
- ML12038A135 +
- ML11305A239 +
- ML11277A270 +
- ML11272A130 +
- ML11272A129 +
- ML11262A151 +
- IR 05000346/2018002 +
- ML18222A345 +
- IR 05000316/1978037 +
- ML050820186 +
- ML040210738 +
- ML20237L595 +
- ML20236P978 +
- IR 05000338/2012003 +
- 1CAN059501, Monthly Operating Rept for Apr 1995 for ANO Unit 1 +
- 05000423/LER-1987-034-01, :on 870923,during Full Power in Mode 1,reactor Trip Occurred Due to Lo Lo Steam Generator Level.Caused by Failure of Solenoid Valve Which Controls Hydraulic Oil Flow to Isolation Valve.Solenoid Replaced +
- 05000414/LER-1987-024-01, :on 870807,automatic Main Feedwater Isolation Occurred Due to hi-hi Steam Generator Water Level.Caused by Mgt Deficiency.Steam Generator Water Level Restored & Incident Will Be Discussed at Meeting +
- 05000219/LER-1988-008, :on 880414,reactor Bldg Isolation & Standby Gas Treatment Sys Automatic Initiation Occurred.Caused by Personnel Error.Emergency Operating Procedures Entered for Secondary Containment Control +
- 05000382/LER-1988-005, :on 880321,blown Undervoltage Circuit Fuse Replacement Results in Tech Spec 3.0.3 Entry.Caused by Inadvertent Shortening of Two Wire Connections.Change to Tech Spec Being Pursued to Correct Deficiency +
- 05000440/LER-1996-008, :on 961004,degraded Breaker Results in Loss of Safety Function & Exceeding TS Action Statements.Caused by Sensor Leads Installed Backwards.Circuit Breaker EF-1-D-09 Replaced +
- 05000499/LER-1996-003, :on 960828,failure to Fully Meet Requirements of TS Occurred,Due to Discovery of Improperly Installed Jumper on Main Steam Line Pressure Lead/Lag Circuit Card. Personnel Issues Have Been Addressed +
- 05000341/LER-1993-002, :on 930114,HPCI Sys Failed to Start on Simulated Auto Injection Signal During Performance of Surveillance.Caused by Loss of Supply Voltage to Governor Control sys.Voltage-dropping Resistor Replaced +
- 05000440/LER-1995-008, :on 950911,reactor Scram Occurred Due to Trip of Main Turbine & Subsequent Closure of Turbine Control & Stop Valves.Replaced Inverter & Restored Instrument Power Supply +
- 05000254/LER-1991-027-01, :on 911216,leak from Drain Valve,Water Drained Through a Floor Pipe Onto an Emergency Bus.Caused by Leak from Reactor Bldg Sys Through Manual Drain Valve Which Was Open.Drain Valve Closed +
- 05000155/LER-1978-005-03, /03L-0:on 780203,during Plant Startup,Proper Offgas Sample Monitor Flow Could Not Be Established Using Flow Control Valves in Sample Sys.Probably Caused by Inadequate Cleaning of Flow Instrument by Maint Personnel +
- 05000293/LER-1980-023-03, /03L-0:on 800526,during Surveillance Testing, Channel B of Rod Block Monitor Sys Determined to Be Out of Calibr.Caused by Misinterpertation of Tech Specs. Requalification Program Will Include Sys Review +
- 05000416/LER-2018-010-01, Reactor Manual Scram Due to Main Steam Bypass Stop and Control Valve Drifting Open +
- 05000416/LER-2018-010, Reactor Manual Scram Due to Main Turbine Bypass Valve Drifting Open +
- 05000316/LER-2078-037, Letter from Indiana & Michigan Power Co to NRC Submitting Licensee Event Report (RO 50-316/78-037), Stating Corrective Actions Taken +
- 05000296/LER-1999-004-02, :on 990625,facility Core Spray Divisions I & II Inoperable at Same Time Due to Personnel Error.Electrical Supply Breaker to Core Spray Division II Pump 3B Returned to Normal Racked in Position +
- 05000346/LER-2016-008, Regarding Application of Technical Specification for the Safety Features Actuation System Instrumentation +
- 05000454/LER-2015-003, Re One Train of Diesel Generator System Inoperable Longer than Allowed by Technical Specifications Due to Loss of Diesel Fuel Oil System Volume +
- 05000354/LER-2005-003, Regarding Reactor Coolant System Leak from Check Valve Position Indicator +
- 05000316/LER-1978-037-01, /01T-1:on 780615,both Diesel Generators Placed in Condition Where Neither Engine Capable of Automatic Start. Operator Closed & Tagged Out Starting Air Pilot Valves on Wrong Diesel Generator.Operator Reprimanded +