- 05000325/LER-2005-004 +
- 05000272/LER-1991-019, :on 910428,three Cases of Tech Spec Noncompliance Occurred.Caused by Inadequate Procedures & Personnel Errors.Operations Dept Procedures Revised & Event Reviewed +
- ML050690099 +
- ML030420118 +
- ML20086G160 +
- ML20100R429 +
- ML20134K820 +
- ML20214L129 +
- ML20211H412 +
- 05000301/LER-1987-005, :on 871120,control Rod C7 Discovered to Be Out of Alignment.Caused by Blown Fuse.Quadrant Flux Tilt Verified & Found Acceptable.Fuse Replaced +
- 05000267/LER-1987-005, :on 870219,Loop II Shutdowns Occurred.Caused by Personnel Error,Inadequate Clearance,Insufficient Detail in Functional Test & Design Wiring Error.Personnel Responsible for Design Wiring Error Reprimanded +
- 05000440/LER-1997-002, :on 970211,breaker Trip Caused Loss of Electrical Power to Non-Class 1E Bus & Resulted in ESF Actuation.Caused by Random Component Failure.Ground Fault Replaced +
- 05000293/LER-1996-005, :on 960419,automatic Scram Occurred Due to Turbine Vibration During Planned Power Reduction.Turbine Vibration Trip Setting That Initiates Trip of Turbine Due to High Vibration Changed +
- 05000423/LER-1991-015-01, :on 910617,both Trains of SLCRS Became Inoperable When Access Cover for Common Exhaust Duct Was Removed Due to Deficient Procedure.Applicable Damper Testing Procedure Will Be Revised +
- 05000261/LER-1983-014-01, /01T-0:on 830704,svc Water Leak Discovered on Containment Fan Cooler HVH-2,resulting in Degradation of Containment Boundary Per IE Bulletin 80-24.Caused by Corrosion/Erosion of Cooler Tubing +
- 05000272/LER-1982-024-03, /03L-0:on 820410,during Surveillance Testing,Svc Water Flow to Containment Fan Coil Unit 12 Was Less than Required.Caused by Stuck Flow Control Valve 12SW223.Valve Exercised +
- ML20035E799 +
- 05000311/LER-1994-007-01, :on 940411,infeed Breakers to 4 Kilovolt Vital Buses Tripped on Undervoltage Signal.Caused by Personnel Error.Corrective Action:Involved Technician Counseled Re Identifying Components +
- 05000272/LER-1991-032, :on 911114,containment purge/pressure-vacuum Relief Sys Isolation Signal Actuated.Caused by High Channel Spike on Containment Particulate Radiation Monitor 1R11A. Channel Calibr Check Performed Satisfactorily +
- 05000397/LER-1994-018, :on 941115,util Failed to Comply W/Ts Action Requirement While Inoperable Control Rod Block Instrumentation Resulted in Exceeded Allowed Outage Time. Placed Channel a Trip Function in Tripped Condition +
- 05000397/LER-1993-026, :on 930619,failed to Complete Weekly Battery Surveillance Requirements within Allowed TS Interval Due to Scheduling Oversight.Initiated & Completed PPM 7.4.8.2.1.20 +
- 05000261/LER-2007-001, From H. B. Robinson Steam Electric Plant, Unit 2, Reactor Trip Due to a Loose Wire in the Main Transformer Monitoring Circuitry +
- 05000266/LER-1998-002, :on 980108,failure of High Voltage Station Auxiliary Transformer Occurred Due to Ground in Low Voltage Side Bus Duct.Operability of 1X03 Was Restored & Verified to Be in Operation by Infrared Scan +
- 05000272/LER-1982-024, Svc Water Flow to Containment Fan Coil Unit 12 Discovered Less Required than 700 Gpm.Caused by Closed Flow Control Valve 125w223.Valve opened.W/831117 +