- 05000443/LER-1992-026, :on 920714,discovered That Three of Four Cover Bolts on Resin Sluice Discharge Valve Fractured,Resulting in Loosening of Valve Bonnet.Caused by High Matl Hardness.Bolts in Plug Valves Replaced + (ML20134B288)
- ML20134B289 + (ML20134B289)
- 05000443/LER-1993-004, :on 930118,determined That 4 H Flow Estimate for Effluent Releases W/Flowmeter Inoperable Exceeded by 35 Minutes.Caused by Chemistry Technician Error.Technician Counseled & Event Will Be Reviewed + (ML20134B290)
- ML20134B291 + (ML20134B291)
- ML20134B292 + (ML20134B292)
- ML20134B294 + (ML20134B294)
- ML20134B295 + (ML20134B295)
- ML20134B296 + (ML20134B296)
- 05000362/LER-1993-001, :on 930116,main Generator Tripped on Stator Ground Protection Signal Causing Turbine/Reactor Trip.Caused by Water Intrusion.Addl Sealing Provided for Main Generator Terminal Encl to Minimize Water Intrusion + (ML20134B297)
- 05000341/LER-1993-003, :on 930106,TS Required Recorder Discovered Not to Be Qualified Due to Procedural deficiency.Non-qualified Recorder Installed in Main Control Room Div 2 Panel Replaced W/Qualified Recorder + (ML20134B299)
- ML20134B301 + (ML20134B301)
- 05000266/LER-1993-001, Revised LER 93-001-00:on 930107,all 4,160 Volt Degraded Grid Voltage Protection Channels Declared Inoperable Due to Discovery That Settings for Relays on Subj Channels Being Too Low.Plant Mods Will Be Made + (ML20134B302)
- ML20134B304 + (ML20134B304)
- 05000353/LER-1993-002-01, :on 930124,improperly Connected Wires Discovered in Circuit Breakers Caused EDG to Be Inoperable & Violation of TS to Occur.Procedure S93.O.C Will Be Revised + (ML20134B307)
- ML20134B308 + (ML20134B308)
- ML20134B309 + (ML20134B309)
- 05000344/LER-1993-001, :on 921008,determined That Sleeved Conduit Penetration Did Not Have Internal Seal Between Sleeve & Conduit Due to Personnel Error.Incorrect Drawing A-116 Revised to Show Wall Containing Penetration + (ML20134B310)
- ML20134B311 + (ML20134B311)
- ML20134B313 + (ML20134B313)
- 05000271/LER-1992-017, :on 920529 & 0623,EDG a Rendered Inoperable After Completing 8 H Monthly Surveillance.Caused by Crack in Cylinder Liner 7 & Cylinder Liner 10.Cylinder Liners Replaced.Not Reportable Per Part 21 + (ML20134B314)
- ML20134B315 + (ML20134B315)
- ML20134B318 + (ML20134B318)
- ML20134B319 + (ML20134B319)
- ML20134B322 + (ML20134B322)
- ML20134B323 + (ML20134B323)
- ML20134B325 + (ML20134B325)
- ML20134B327 + (ML20134B327)
- IR 05000528/1977003 + (ML20134B328)
- ML20134B330 + (ML20134B330)
- ML20134B332 + (ML20134B332)
- ML20134B336 + (ML20134B336)
- ML20134B337 + (ML20134B337)
- ML20134B339 + (ML20134B339)
- ML20134B340 + (ML20134B340)
- ML20134B342 + (ML20134B342)
- ML20134B344 + (ML20134B344)
- ML20134B346 + (ML20134B346)
- ML20134B348 + (ML20134B348)
- ML20134B351 + (ML20134B351)
- ML20134B354 + (ML20134B354)
- ML20134B356 + (ML20134B356)
- ML20134B358 + (ML20134B358)
- ML20134B359 + (ML20134B359)
- ML20134B361 + (ML20134B361)
- ML20134B362 + (ML20134B362)
- ML20134B363 + (ML20134B363)
- ML20134B364 + (ML20134B364)
- ML20134B365 + (ML20134B365)
- ML20134B366 + (ML20134B366)
- ML20134B368 + (ML20134B368)
- ML20134B372 + (ML20134B372)