- HL-4877, Forwards Core Shroud Stabilizer Design Submittal,Providing Analyses & Conclusions Supporting Implementation of Facility Shroud Repair.Ge Proprietary Info Also Encl.Ge Proprietary Info Withheld Per 10CFR2.790 + (ML20086E798)
- ML20086E802 + (ML20086E802)
- B13982, Forwards Comments on Draft AEOD Special Rept, Experience W/ Pump Seals Installed in Reactor Coolant Pumps Mfg by Byron Jackson + (ML20086E804)
- ML20086E808 + (ML20086E808)
- ML20086E810 + (ML20086E810)
- ML20086E812 + (ML20086E812)
- ML20086E813 + (ML20086E813)
- ML20086E814 + (ML20086E814)
- 05000373/LER-1991-017-02, :on 911023,reactor Core Isolation Cooling Turbine Tripped on Mechanical Overspeed.Caused by Failure of Governor Valve to Close During Start of Sys.Mechanical Valve & Electrical Governor Actuator Inspected + (ML20086E815)
- ML20086E823 + (ML20086E823)
- ML20086E824 + (ML20086E824)
- ML20086E826 + (ML20086E826)
- 05000373/LER-1991-016-01, :on 911024,division 3 125 Volt Dc Battery Inoperable Due to Loose Connection.Cause Unknown.Battery Cable Connection Retorqued & Resistance Measurements Verified + (ML20086E827)
- B13970, Clarifies 911009 Proposed Changes to TS Re Correction of Editorial & Typo Errors,Per Conversations W/Nrc. Nonintent Changes, Defined as Not Changing Intent or Meaning of Subj Matter + (ML20086E828)
- 05000254/LER-1991-021-01, :on 911025,RCIC Declared Inoperable Due to High Pump Flow in IST Required Action Range.Caused by Instrument Drift Due to Aging of Control Room.Control Room Tachometer Indicators Replaced + (ML20086E829)
- ML20086E831 + (ML20086E831)
- ML20086E835 + (ML20086E835)
- ML20086E840 + (ML20086E840)
- ML20086E847 + (ML20086E847)
- ML20086E849 + (ML20086E849)
- NRC-91-0156, Advises That Application for Amend to License NPF-43, Changing Tech Specs Re Emergency Equipment Cooling Water Sys Delayed from 911130 to 1217.Delay Necessary to Generically Resolve Issues in Generic Ltr 91-18 Re Degraded Conditions + (ML20086E850)
- 05000293/LER-1991-023, :on 910728,11 of 76 Drywell Head Bolts Discovered Loose During Integrated Leak Rate Test.Caused by Failure of spherical-type Washer Sets & Use of Wrong Matl. Washer Sets Replaced & Procedure Revised + (ML20086E851)
- ML20086E854 + (ML20086E854)
- 05000354/LER-1995-008, :on 950608,reviewer Determined Procedure Rev Would Render HPCI Inoperable During Jockery Pump Test.Caused by Personnel Error.Lessons Learned Will Be Shared W/ Appropriate Individuals + (ML20086E856)
- ML20086E859 + (ML20086E859)
- ML20086E866 + (ML20086E866)
- ML20086E893 + (ML20086E893)
- ML20086E906 + (ML20086E906)
- ML20086E914 + (ML20086E914)
- ML20086E930 + (ML20086E930)
- 05000455/LER-1991-004-13, :on 911030,spurious Train B Feedwater Isolation Signal Generated,Causing Tempering Line Flow Control & Downstream Isolation Valves to Close.Caused by Failure of Logic Card.Isolation Reset + (ML20086E943)
- ML20086E980 + (ML20086E980)
- ML20086E997 + (ML20086E997)
- ML20086F020 + (ML20086F020)
- ML20086F026 + (ML20086F026)
- 05000261/LER-1977-008, :on 770424,control Rod N-9 Failed to Fall Into Core Following Power Reactor Trip.Caused by Drive Mechanism Malfunction.Shutdown Bank a Withdrawn & Realigned w/N-9.Rod Drop Test Performed + (ML20086F036)