Rev 0 to Field Disposition Instruction (Fdi) HT2-0121-12900. Fdi Documents Design Requirements & Matl Required to Install Stabilizers for Shroud Horizontal WeldsML20086E847 |
Person / Time |
---|
Site: |
Hatch |
---|
Issue date: |
06/19/1995 |
---|
From: |
Trovato J GENERAL ELECTRIC CO. |
---|
To: |
|
---|
Shared Package |
---|
ML19325F570 |
List: |
---|
References |
---|
HT2-0121-12900, HT2-121-12900, NUDOCS 9507120288 |
Download: ML20086E847 (6) |
|
Similar Documents at Hatch |
---|
Category:TECHNICAL SPECIFICATIONS & TEST REPORTS
MONTHYEARML20212J2721999-10-0101 October 1999 Proposed Tech Specs,Modifying DG Fuel Oil Storage Requirements ML20210G2971999-07-29029 July 1999 Proposed Tech Specs LCO 3.1.7 Re Standby Liquid Control Sys ML20210A4041999-07-15015 July 1999 Ei Hatch Nuclear Plant Unit 1,Extended Power Uprate Startup Test Rept for Cycle 19 ML20204J6031999-03-19019 March 1999 Ei Hatch Nuclear Plant Unit 2 Extended Power Uprate Startup Test Rept for Cycle 15 ML20203C5931999-02-0505 February 1999 Proposed Tech Specs Pages Revising TS to Implement Previously Approved Generic Changes ML20199J9081999-01-21021 January 1999 Proposed Tech Specs Increasing Allowable Values for Reactor Bldg & Refueling Floor Ventilation Exhaust Radiation Monitors ML20197H5171998-12-0404 December 1998 Proposed Tech Specs Section 2.1.1.2,deleting Footnote Which Specifies That SLMCPRs Are for Cycle 18 Only & TS Section 5.6.5.b.2 ML20236U2551998-07-22022 July 1998 Proposed Tech Specs Increasing Allowable Values for High Radiation Trip for Reactor Bldg & Refueling Floor Ventilation Exhaust Monitors ML20217A0861998-04-30030 April 1998 Ei Hatch Nuclear Plant,Units 1 & 2,Process for Implementing Technical Requirements of 10CFR54,License Renewal Rule HL-5558, Edwin I Hatch Nuclear Plant,Unit 1,Power Uprate Startup Test Rept for Cycle 181998-02-17017 February 1998 Edwin I Hatch Nuclear Plant,Unit 1,Power Uprate Startup Test Rept for Cycle 18 ML20197K1861997-12-18018 December 1997 Marked-up Pages to Licenses DPR-57 & NPF-5,respectively. Proposed Changes Delete or Modify Existing License Conditions,Surveillance Requirements That Have Been Completed & Exemptions That Are No Longer in Effect ML20211J1861997-10-0101 October 1997 Corrected TS Pages Unit 1 & 2 Page 3.4-8,Unit 1 Page 3.5-6 & Unit 2 Page 3.5-5 Provided in Order for Util to Issue Amends 208 & 150 to Manual Holders ML20211A2301997-09-19019 September 1997 Proposed Tech Specs Page 2.0-1 & Corresponding mark-up Page Re SLMCPR ML20210J0491997-08-0808 August 1997 Proposed Tech Specs,Allowing Plant to Operate at Uprated Power Level of 2763 Mwt Which Represents Power Level Increase of 8% HL-5438, Ei Hatch Nuclear Plant - Unit 2 Power Uprate Startup Test Rept for Cycle 141997-07-21021 July 1997 Ei Hatch Nuclear Plant - Unit 2 Power Uprate Startup Test Rept for Cycle 14 ML20141B7591997-05-0909 May 1997 Proposed Tech Specs 2.1.1.2,revising Safety Limit Minimum Critical Power Ratio to Reflect Results of Cycle Specific Calculation Performed for Unit 1 Operating Cycle 18,expected to Commence in Nov 1997 ML20141B8561997-05-0909 May 1997 Proposed Tech Specs,Revising Operability Requirements for Rod Block Monitor Sys HL-5376, Proposed Tech Specs 3.4.9 Re Reactor Coolant Sys Pressure & Temp Limits1997-04-29029 April 1997 Proposed Tech Specs 3.4.9 Re Reactor Coolant Sys Pressure & Temp Limits ML20133F3641997-01-0707 January 1997 Proposed Tech Specs Providing Alternate Method of Testing S/Rvs During Shutdown Conditions Rather than During Unit Startup as Is Currently Done ML20138G6271996-12-19019 December 1996 Rev 11 to ODCM for Ei Hatch Nuclear Plant ML20132G2261996-12-17017 December 1996 Proposed Tech Specs Re pressure-temp Limits ML20132E0161996-12-13013 December 1996 Proposed Tech Specs Re Physical Security & Contigency Plan & Guard Training & Qualification Plan ML20135D4881996-12-0303 December 1996 Proposed Tech Specs Revising SLMCPR Values Based Upon Unique plant-evaluations for Current Cycle 13 & Use of GE-13 Fuel in Next Cycle 14 ML20129H9181996-10-29029 October 1996 Proposed Tech Specs,Associating Changes W/Installation of Digital Power Range Neutron Monitoring Sys & Incorporation of long-term Stability Solution Hardware ML20128M8701996-10-0707 October 1996 Proposed Tech Specs to Licenses DPR-57 & NPF-5,increasing Nominal Mechanical Pressure Relief Setpoints for All SRVs & Allow Operation W/One SRV & Associated Functions Inoperable ML20113F5541996-09-19019 September 1996 Proposed Tech Specs,Clarifying Applicability of Certain Surveillances Addressing Rvp & Temp Limits & Replacing Vessel Pressure & Temp Limit Curves W/New Curves ML20117M2251996-09-11011 September 1996 Proposed Tech Specs,Authorizing Southern Nuclear to Become Licensed Operator & to Have Exclusive Responsibility & Control Over Physical Const,Operation & Maint of Plant HL-5192, Edwin I Hatch Nuclear Plant,Unit 1,Power Uprate Startup Test Rept for Cycle 171996-07-18018 July 1996 Edwin I Hatch Nuclear Plant,Unit 1,Power Uprate Startup Test Rept for Cycle 17 ML20115J4861996-07-16016 July 1996 Proposed Tech Specs,Reflecting Changes Through June 1996, Satisfying Requirements of 10CFR50.71 ML20212C1491996-05-31031 May 1996 Stability Monitor ML20117H1391996-05-21021 May 1996 Proposed Tech Specs 3.5.2,ECCS - Shutdown & 3.5.2.2.b SR for Units 1 & 2 Revise to Change Unit 1 CST Water Level Requirement from 12 Feet to 13 Feet & Change Unit 2 CST Water Level Requirement from 12 Feet to 15 Feet ML20100P1041996-03-0404 March 1996 Ei Hatch Nuclear Plant Unit 2 Power Uprate Startup Test Rept for Cycle 13 ML20100H7431996-02-21021 February 1996 Proposed Tech Specs,Revising Changes of Drywell Air Temp LCO from 350 F to 150 F ML20094K3831995-11-10010 November 1995 Proposed Tech Specs,Reflecting Implementation of 10CFR50,App J,Option B ML20093G9401995-10-0505 October 1995 Inservice Insp Program Third 10-Year Interval for Ei Hatch Nuclear Plant Units 1 & 2 ML20092H6461995-07-24024 July 1995 Ei Hatch Nuclear Plant Units 1 & 2 IST Program ML20085K4011995-06-20020 June 1995 Proposed Tech Specs for Power Uprate ML20086E8471995-06-19019 June 1995 Rev 0 to Field Disposition Instruction (Fdi) HT2-0121-12900. Fdi Documents Design Requirements & Matl Required to Install Stabilizers for Shroud Horizontal Welds ML20086E8311995-06-0909 June 1995 Rev 0 to Fabrication Spec 25A5719, Fabrication of Shroud Stabilizer ML20086E8141995-06-0606 June 1995 Rev 1 to Code Design Spec 25A5717, Shroud Stabilizers ML20085A1661995-06-0606 June 1995 Proposed Tech Specs Re Secondary Containment Draw Down & Vacuum Surveillance Requirement Acceptance Criteria ML20086E8121995-05-17017 May 1995 Rev 0 to Design Spec 25A5718, Shroud Repair Hardware ML20082V3791995-05-0404 May 1995 Proposed Tech Specs,Minimizing Thermal Stratification Events ML20082L3331995-04-14014 April 1995 Proposed Tech Specs Re Elimination of Selected Response Time Testing Requirements from TS ML20081F3471995-03-14014 March 1995 Proposed Improved Ts,Permitting Drywell & Wetwell Purge Valves Isolated by Drywell Radiation Monitor Signal to Be Opened W/Inoperable Drywell Radiation Monitor ML20077S0331995-01-13013 January 1995 Proposed Tech Specs Allowing Plant to Operate at Uprated Power Level of 2558 Mwt ML20077D8921994-12-0202 December 1994 Proposed Deleted ETS ML20078G7161994-11-0101 November 1994 Proposed Tech Specs,Converting Current TSs to Improved TS Consistent w/NUREG-1433 ML20076L6911994-10-19019 October 1994 Proposed Improved Tech Specs,Rev F ML20149G3751994-10-13013 October 1994 Proposed Tech Specs,Lowering ATWS-RPT Setpoint by Approx 2 Ft 2 Inches Allowing Restarting Recirculation Pump Following RPT When Temp Differential Between Coolant at Reactor Bottom Head & Reactor Steam Dome Cannot Be Obtained 1999-07-29
[Table view] Category:TEST/INSPECTION/OPERATING PROCEDURES
MONTHYEARML20217A0861998-04-30030 April 1998 Ei Hatch Nuclear Plant,Units 1 & 2,Process for Implementing Technical Requirements of 10CFR54,License Renewal Rule ML20138G6271996-12-19019 December 1996 Rev 11 to ODCM for Ei Hatch Nuclear Plant ML20093G9401995-10-0505 October 1995 Inservice Insp Program Third 10-Year Interval for Ei Hatch Nuclear Plant Units 1 & 2 ML20092H6461995-07-24024 July 1995 Ei Hatch Nuclear Plant Units 1 & 2 IST Program ML20086E8471995-06-19019 June 1995 Rev 0 to Field Disposition Instruction (Fdi) HT2-0121-12900. Fdi Documents Design Requirements & Matl Required to Install Stabilizers for Shroud Horizontal Welds ML20086E8311995-06-0909 June 1995 Rev 0 to Fabrication Spec 25A5719, Fabrication of Shroud Stabilizer ML20086E8141995-06-0606 June 1995 Rev 1 to Code Design Spec 25A5717, Shroud Stabilizers ML20086E8121995-05-17017 May 1995 Rev 0 to Design Spec 25A5718, Shroud Repair Hardware ML20106A6521992-02-29029 February 1992 Proposed Rev 3 to Ei Hatch Nuclear Plant Solid Radwaste PCP, Per GL 89-01 ML20106A6501992-02-0707 February 1992 Rev 7 to Ei Hatch Nuclear Plant ODCM, Reflecting Proposed Changes,Per GL 89-01 ML20056B3031990-08-0101 August 1990 Ei Hatch Nuclear Plant,Units 1 & 2 Inservice Insp Program Second 10-Yr Interval ML20149N1141988-01-0404 January 1988 Revised Second 10-Yr Interval Inservice Insp Program,1980 Edition of ASME Section XI W/Addenda Through Winter 1981 ML20211H5491987-02-20020 February 1987 IGSCC-Susceptible Primary Pressure Boundary Stainless Steel Piping & Components Insp/Mitigation Program, 1987 Maint/Refueling Outage ML20245B8301986-12-10010 December 1986 Rev 0 to SO-OPS-05-1286, Spent Fuel Pool Transfer Canal Gates ML20245B8171986-12-0505 December 1986 Rev 0 to SO-OPS-02-1286, Processing of Water from Yard Drains ML20245B8201986-12-0505 December 1986 Rev 0 to SO-OPS-01-1286, Radwaste Discharges. Supporting Documentation Encl ML20203L9291986-08-0101 August 1986 Rev 0 to Training Procedure 72TR-TRN-002-0S, License Requalification Training Program ML20137V9031985-12-0505 December 1985 Rev 1 to Emergency Implementing Procedure 62RP-RAD-009-05, Airborne Radioactivity Concentration Determination ML20076J1871985-11-0808 November 1985 Rev 2 to Technical Note 20684-EIH, Thermo-Lag 330 Fire Barrier Sys Installation Procedures Manual Prepared for Bechtel Power Corp for Georgia Power Co ML20076J1911985-11-0404 November 1985 Rev 1 to Technical Note 20684-EIH, Thermo-Lag 330 Fire Barrier Sys Installation Procedures Manual Prepared for Bechtel Power Corp,For Georgia Power Co ML20076J1961985-10-23023 October 1985 Rev 0 to Technical Note 20684-EIH, Thermo-Lag 330 Fire Barrier Sys Installation Procedures Manual Prepared for Bechtel Power Corp,For Georgia Power Co ML20135F3161985-08-26026 August 1985 Rev 1 to Emergency Operating Procedures Implementation Plan for Emergency Response Capability Project ML20132E5471985-08-23023 August 1985 Rev 0 to Engineering Svc Procedure 42EN-ENG-011-OS, Scram/ Transient Reporting ML20209F2391985-07-0101 July 1985 Recirculation,Rhr & Reactor Water Cleanup Sys Piping Weld Joint Insp/Mitigation Program for 1985 Maint/ Refueling Outage ML20128A0561985-06-25025 June 1985 Inservice Insp Program,1980 Edition of ASME Section XI W/Addenda Through Winter 1981 ML20126E8331985-06-11011 June 1985 Emergency Plan Implementing Procedures & Deleted Title Sheets,Including Procedures HNP-8007 Re Decontamination of Clothing & Hats & HNP-8004 Re Dosimetry Issuance & Tracking ML20116D4401985-04-23023 April 1985 Revised Emergency Procedures HNP-8109 Re Continuous Air Monitors Models AM-3D & AM-33-1,HNP-8122 Re Radiation Monitor Model RM-16 & HNP-8146 Re Rascal Portable Rate Meter-Scaler/Model PRS-1 Operation & Calibr ML20245B7911985-04-17017 April 1985 Rev 0 to 10AC-MGR-04-0, Deficiency Control Sys. Supporting Documentation Encl ML20107G1421985-02-15015 February 1985 Revised Emergency Implementing Procedures,Including Rev 3 to HNP-8161 Re Eberline Model PCM-1 Portable Monitor Operation & Calibr & Rev 2 to HNP-8036 Re Waste Classification & Manifest Reporting Resin Shipments ML20215F7371984-12-26026 December 1984 Rev 1 to Administrative Control Procedure 40AC-FPX01-0, Fire Protection Program. Portions of Procedures 34AB-OPS-056-1S & 34AB-OPS-056-2S Encl ML20101B0551984-12-17017 December 1984 Rev 5 to Emergency Plan Implementing Procedure HNP-8134, Whole Body Counter Sys ML20108E0921984-11-29029 November 1984 Rev 10 to Procedure Data Package HNP-1-3980-1, Kinemetrics SMA-3 ML20107H5701984-10-31031 October 1984 Detailed Control Room Design Review Program Plan ML20155C8961984-09-30030 September 1984 Rev 1 to Offsite Dose Calculation Manual ML20155C8841984-09-30030 September 1984 Rev 1 to Solid Radwaste Process Control Program ML20098G3401984-09-30030 September 1984 Offsite Dose Calculation Manual ML20098G3381984-09-30030 September 1984 Solid Radwaste Process Control Program ML20108E0741984-06-13013 June 1984 Rev 10 to Procedure HNP-1-3980-M, Seismic Instrumentation Functional Test & Calibr ML20084H4971984-05-0101 May 1984 Rev 0 to Procedures Generation Package for Emergency Operating Procedures,Including plant-specific Technical Guidelines for Units 1 & 2,plant-specific Writers Guide & Implementation Plan for Emergency Response Project ML20086U4131984-02-29029 February 1984 Vendor Equipment Technical Info Program, Per Generic Ltr 83-28,Section 2.2.2,final Draft ML20087N9101984-01-26026 January 1984 Public Version of Transmittal & Title Page to Deleted Emergency Plan Implementing Procedures,Including Procedure HNP-8031 Re Determination of Specific Activity of Spent Resin & Curie Contents of Liner & 840322 Memo ML20087M7911984-01-25025 January 1984 Public Version of Transmittal & Title Pages of Deleted Emergency Plan Implementing Procedures HNP-8019, Insp of Steel Radwaste Shipping Drums & HNP-8422, Handling & Loading of Chem-Nuclear Cask & 840322 Memo ML20087M9321984-01-20020 January 1984 Public Version of Rev 7 to Emergency Plan Implementing Procedure HNP-8101, Teletector Model 6112B/D Operation & Calibr & Jm Felton 840322 Release Memo ML20081B6731984-01-18018 January 1984 Public Version of Rev 0 to Emergency Plan Implementing Procedure HNP-8161, Eberline Model PCM-1 Portal Monitor & Rev 17 to HNP-8008, Radiation Work Permit & Jm Felton 830307 Release Memo ML20087P0191984-01-13013 January 1984 Public Version of Revised Emergency Plan Implementing Procedures,Including Procedures HNP-8038 Re Waste Classification & Manifest Reporting & HNP-8042 Re Radiological Work Practices & 840326 Memo ML20079H9011983-12-0707 December 1983 Public Version of Revised Emergency Plan Implementing Procedures,Including Procedures HNP-8035 Re Pulmonary Function Screening Program & HNP-8016 Re Shipment of Radioactive Matl ML20093D4881983-10-31031 October 1983 Public Version of Revised Emergency Plan Implementing Procedures,Including HNP-4858, Naturally Occurring Phenomenon & HNP-8108, Pocket Dosimeter Use & Performance Test. W/831031 & 840709 Release Memo ML20108E0491983-10-28028 October 1983 Rev 4 to Procedure HNP-4858, Naturally Occurring Phenomenon ML20080L0651983-10-12012 October 1983 Rev 1 to Procedure HNP-4848, Determination of Extent of Core Damage Under Accident Conditions ML20081L9461983-10-12012 October 1983 Public Version of Revised Emergency Plan Implementing Procedures,Including Procedures HNP-4827 Re Offsite Radiological Environ Monitoring During Emergencies & HNP-4852 Re Offsite Dose Estimation 1998-04-30
[Table view] |
Text
?
ATTACilMENT 9 GENE FDI NO. IIT2-0121-12900, REVISION O FIELD DISPOSITION INSTRUCTION IIATCII UNIT 2 SIIROUD REPAIR PROGRAM JUNE 1995 4
4 2
9507120288 DR 950703 p ADOCK 05000366 PDR
/
FDINo. HT2-0121-12900 ORIGINAL WHEN RevtSION O Field Disposition Instruction STAW2D !N RED SIIEET I OF 5 PROJECT }{atch UNIT 2 DATEOFISSUEg { g jgg EQUIPMENT Shroud Repair Prograrn J T OVA 7o~ M f d ECN/lR/DDRNDDK MPL NO. B } 1.A001 DESCRIPTION OF TASK I. Purpose This FDI documents the design, requirements and material required to install the stabilizers for the shroud horizontal welds.
II. Required Documents (Supplied by Engineering)
Document Numher Ruhian DescrJtitian A. 107E5734 0 Reactor Modification Drawing B. PL107E5734 0 Parts List, Reactor Modification Drawing C. 25A5720 0 Stabilizer Installation Specification D. 21A2040 1 Cleaning and Cleanliness Control E. 25A5718 0 Shroud Repair Hardware Design Specification F. 25A5717 1 Shroud Stabilizers Code Design Specification G. 25 A5719 0 Shroud Stabilizer Fabrication Specification H. GENE-B11-00637 005 0 Safety Evaluation for Hatch 2 Shroud Repair I. 25A5721 0 Shroud Stabilizers Code Stress Report J. GENE-B11-00637-002 0 Shroud and Repair Hardware Stress Analysis K. GENE B1100637 003 0 Seismic Analysis Report for Hatch 2 Shroud Repair L. QAM-001 4 GE Quality Assurance Manual l
l l
APPROVAL DATE APPROVALS DATE THi3 EQUIPMENT 15 5AFETY RELATED % YES O No gg S AFETY IUNCTION IS AFFECTED O YE3 M No Nekg/A$h!/7/$~ l (LLD WORK ORDLR NO. COMPLET105 RECORD
/51 5 Es NO O GM2 5tA7L APPL i.bGR /
, art,r DtsIRIHUT1oN CODE FDI TASK COMPLETED DATE 1
kl.
ENGR Finer. df Q Q l&WW , INTERNAL EXTE RN AL
$lt L QUALITY CON!ROL Y , $$ Y/9/95 OJLl/l MARAGE R I FIELD MAN AGLR l
Reference DRF Bl1006.17
', s 4 FDI NO. HT2-0121-12900 ORIGINAL WHEN REVISION O FieldDisposition Instruction STAMPED lN RED SHEET 2 OF S III. Material Required (per Paragraph II.A and II.8) i Parts Document Document Parts List Number Revision Description Qty Revision A. I12D6693G001 0 Upper Stabilizer Assembly 4 0 B. I12D6694G001 0 Stabilizer Support Assembly 4 0 C. I12D6695G001 0 Tie Rod Assembly 4 0 D. I12D6696G001 0 Tie Rod / Spring A scembly 4 0 E. I12D6697G001 0 Core Plate Wedge Assembly 4 0 F. I12D6698G001 0 Mid Support Assembly 4 0 G. I12D6699G001 0 Lower Stabilizer Assembly 4 0 H. I12D6759G001 0 Collet Assembly 4 0 I. I12D6700P001 0 Rod, Tie 4 n/a J. I12D6701P001 0 Nut, Tie Rod 4 n/a K. I12D6702P001 0 Spring, Lower 4 n/a L. I12D6704P001 0 Bracket, Upper Spring 4 n/a M. I12D6705P001 0 Support, Upper 4 n/a N. I12D6705P002 0 Support, Upper 4 n/a O. I12D6706P001 0 Support 4 n/a P. I12D6707P001 0 Contact, Lower 4 n/a Q. I12D6709P001 0 Nut, Top Support & Pin Detail 16 n/a R. I12D6709P002 0 Nut, Top Support & Pin Detail 4 n/a S. I12D6709P003 0 Nut, Top Support & Pin Detail 32 n/a T. I12D6709P004 0 Nut, Top Support & Pin Detail 32 n/a U. I12D6709P005 0 Nut, Top Support & Pin Detail 4 n/a V. I12D6709P006 0 Nut, Top Support & Pin Detail 12 n/a W. I12D6710P001 0 Bolt, Top Support 8 n/a X. I12D6712P001 0 Retainer 4 n/a Y. I12D6713P001 0 Spring, Retainer 32 n/a 7.. I12D6714P001 0 Bolt, Jack 8 n/a AA. Il2D6714P002 0 Bolt, Jack 4 n/a BB. I12D6715P001 0 Sleeve, Jack Bolt 12 n/a CC. I12D6717P001 0 Spring, Retainer 4 n/a DD. I12D6718P001 0 Support, Mid 4 n/a EE. I12D6719P001 0 Ring, Mid Support 4 n/a
- FF. I12D6720P001 0 Screw, Mid Support 4 n/a GG. I12D6721P001 0 Wedge, Core Plate 4 n/a
e
, s FDI NO. HT2-0121-12900 ORIGINAL WHEN " ' ' "
FieldDisposition Instruction TAMPED IN RED SHEET 3 OF 5 Parts Document Document Parts List Munihtr Reusian Description Qty Revision HH. I12D6722P001 0 Clip, Core Plate 4 n/a II. I12D6723P001 0 Bolt, Wedge 4 n/a JJ. I12D6724P001 0 Screw, Top Support 16 n/a KK. I12D6725P001 0 Bracket, Top Support 4 n/a LL. I12D6726P001 0 Latch 12 n/a '
MM. I12D6726P002 0 Latch 4 n/a NN. I12D6753P001 0 Wedge, Upper Stabilizer 8 n/a
- 00. I12D6754P001 0 Block, Upper Stabilizer 4 n/a PP. I12D6754P002 0 Block, Upper Stabilizer 4 n/a QQ. I12D6756P001 0 Arm, Upper Stabilizer 4 n/a IUL 112D6757P001 0 Bolt, Upper Stabilizer 8 n/a SS. I12D6758P001 0 Nut, Upper Stabilizer 8 n/a TT. I12D6760P001 0 Collet 4 n/a UU. Il2D6761P001 0 Clevis Pin 4 n/a VV. I12D6762P001 0 Cruciform Spacer 4 n/a WW. I12D6763P001 0 Bolt 8 n/a XX. 112D6764P001 0 Torque Restraint, Part 1 4 n/a YY. I12D6765P001 0 Torque Restraint, Part 2 4 n/a ZZ. I12D6766P001 0 Cruciform Spacer, Part 2 4 n/a AAA. I12D6767P001 0 Cruciform Rod 4 n/a BBB. I12D6768P001 0 Nut 4 n/a CCC. I12D6773P001 0 Torque Restraint, Part 3 4 n/a DDD. I12D6774P001 0 Bolt, Torque Restraint 4 n/a IV. Repair Procedure Mt of the stabilizer installation shall be performed under water. All work shall be performed in accordance widi
!. i%craph II.A and ll.C.
1.0 Shroud Top Flange and Support Machine the required slots in the shroud top flange, and the required holes in the shroud support, per ll.A.
2.0 Repair Hardware Installation Install the four stabilizers in accordance with the requirements in Paragraph II.A and II.C.
1
HT2-0121-12900 MW& FDINO.
ORIGINAL WHEN REVISION 0 [
FieldDisposition Instruction STAMPED IN RED S!!EET 4 OF 5 1
3.0 Repair Examination
!~
A visual examination of the completed repair shall be performed. The television camera shall be capable of resolving a .001 inch diameter wire on a neutral gray background.
- a. Examine each clevis pin to assure that it is properly located and in correct contact with the bottom of the slot in the lower spring. ,
- b. Examine the core plate wedge assemblies to assure that they are properly seated.
- c. Examine the stabilizer assemblies for contact between the RPV wall and the upper stabilizers (2 contacts each), mid supports (2 contacts each), and lower contacts (1 contact each).
- d. Examine the stabilizer assemblies for contact between the shroud and the upper support (1 contact each) and lower spring (1 contact each). ;
V. Quality Requirements 1.0 GE Site Quality Control Representatives shall provide QC surveillance and document the field work performed, to insure that the requirements of this FDI have been met. All work is to be performed in accordance with GE Quality Assurance Manual QAM-001. '
2.0 The following shall be the minimum Quality Control Documentation Requirements: ,
- a. Video tape of the completed repair.
- b. Process documentation and inspection data sheets as applicable.
- c. As-built dimensions per II.A.
3.0 The following procedures and supporting documentation shall be submitted to GE Site QA and Plant Owner (as applicable) for review, and approval obtained prior to use. Previously approved GENE procedures may be used in satisfying the requirements of this paragraph provided they are approve i by the Plant Owner.
- a. Installation procedures, travelers, or sequence data sheets, drawings, skett,hes, instructions, etc. '
These procedures or travelers shall include cleaning and cleanliness, tool control, machining ;
processes, and visual inspection methods.
- b. Hardware certifications.
HT2-0121 12900 GE W ORIGIN AL WHEN FDINO.
STAMPED IN RED nsvissou o Field Disposition Instruction SHEET 5 OF 5 VI. Safety / Reliability Safety and reliability have been considered in the issue of the design documents for this project. The requirements for this design are contained in the Design Specifications 25A5718 and 25A5717. The seismic analysis of the repair is documented in GENE-B11-00637-003. The structural analysis of the repair is documented in GENE-B11-00637-002 and Specification 25A5721. The safety evaluation for the repair is contained in GENE-B11-00637-005. No new safety requirements, reviews or technical specifications are '
required by this FDI.
l 1
l l
. . - . - - - . - . . . - . ., . - - - - _ - _ _. . . . - - - _ , - . - - - , - . _ - . - .-