Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20080B547 + (ML20080B547)
- 3F1194-10, Submits Preliminary Results of Refuel 9 OTSGs Tube Pull,Per Commitment in Response to 940426 Cal,Item 8.Preliminary Rept, Exam of Crystal River-3 Pulled SG Tubes Encl.Final Rept Will Be Provided by 950531 + (ML20080B551)
- ML20080B553 + (ML20080B553)
- ML20080B555 + (ML20080B555)
- 05000311/LER-1983-067-03, /03L-0:on 831231,during Surveillance Testing, Diesel Generator 2B Experienced Fuel Oil Leak on Cylinder Injector 8R.Caused by Fuel Oil Manifold to Injector Gasket Leakage.Gasket Replaced + (ML20080B558)
- 05000443/LER-1994-017, :on 941102,insp of Cooling Basin Revealed Two Degraded Column Flange Bolts on Cooling Tower Svc Water Pump 1SW-P-110A.Caused by Bolt Mfg Failure to Perform Adequate Heat Treatment.Suspect Bolting Matl Replaced + (ML20080B561)
- ML20080B563 + (ML20080B563)
- ML20080B564 + (ML20080B564)
- ML20080B579 + (ML20080B579)
- ML20080B585 + (ML20080B585)
- ML20080B587 + (ML20080B587)
- ML20080B589 + (ML20080B589)
- NRC-84-0024, Forwards Addl Info to Resolve Power Sys Branch SER Licensing Confirmatory Issues Re Physical Separation of Load Shedder & Emergency Load Sequencer Panels,Reliability of Panels & Separation of Redundant Offsite Power Sys Circuits + (ML20080B596)
- ML20080B598 + (ML20080B598)
- 05000395/LER-1984-001, :on 831223-27 & 29,daily Grab Samples of Svc Effluent Not Taken.Caused by Personnel Error.Individual Disciplined.Separate List of Daily,Weekly & Monthly Tech Spec Requirements Being Generated + (ML20080B613)
- ML20080B632 + (ML20080B632)
- ML20080B636 + (ML20080B636)
- ML20080B640 + (ML20080B640)
- 05000265/LER-1984-002-02, :on 840106,both Distribution Panels Inadvertently Deenergized Simultaneously,Causing Reactor Scram.Caused by Cognitive Error on Part of Engineer.Scram Reset.No Corrective Action Necessary + (ML20080B641)
- ML20080B648 + (ML20080B648)
- ML20080B654 + (ML20080B654)
- ML20080B660 + (ML20080B660)
- ML20080B666 + (ML20080B666)
- ML20080B674 + (ML20080B674)
- ML20080B680 + (ML20080B680)
- ML20080B687 + (ML20080B687)
- ML20080B704 + (ML20080B704)
- ML20080B726 + (ML20080B726)
- ML20080B729 + (ML20080B729)
- ML20080B733 + (ML20080B733)
- ML20080B738 + (ML20080B738)
- ML20080B739 + (ML20080B739)
- ML20080B744 + (ML20080B744)
- 05000321/LER-1994-013, :on 941103,false Low Turbine Speed Signal Resulted in Inoperable HPCI Sys.Caused by Failure or Misadjustment of Turbine Magnetic Speed Pickup.Magnetic Speed Pickup Replaced + (ML20080B745)
- ML20080B749 + (ML20080B749)
- ML20080B752 + (ML20080B752)
- 05000336/LER-1994-035, :on 941102,discovered That Roving Fire Watch Established for Breached Electrical Penetration When Requirement for Continuous Fire Watch.Caused by Personnel Error.Continuous Fire Watch Established + (ML20080B753)
- 05000336/LER-1994-033, :on 941031,loss of Containment Integrity Discovered During Course of Irradiated Fuel Movement within Containment.Caused by Failed Ventilation Exhaust Damper.Fuel Movement Stopped + (ML20080B761)
- ML20080B762 + (ML20080B762)
- ML20080B765 + (ML20080B765)
- 05000277/LER-1983-028-03, /03L-0:on 831223,while Performing Surveillance Testing,Hpsw Pump 2B Declared Inoperable Due to Low Flow. Caused by Internal Wear to Valve Disc Pin & Arm.Parts Replaced + (ML20080B774)
- ML20080B777 + (ML20080B777)
- ML20080B781 + (ML20080B781)
- ML20080B783 + (ML20080B783)
- ML20080B787 + (ML20080B787)
- ML20080B791 + (ML20080B791)
- ML20080B798 + (ML20080B798)
- ML20080B800 + (ML20080B800)
- ML20080B808 + (ML20080B808)
- ML20080B816 + (ML20080B816)
- ML20080B820 + (ML20080B820)