- ML20072T952 + (ML20072T952)
- ML20072T954 + (ML20072T954)
- ML20072T962 + (ML20072T962)
- ML20072T969 + (ML20072T969)
- ML20072T973 + (ML20072T973)
- ML20072T976 + (ML20072T976)
- ML20072U002 + (ML20072U002)
- ML20072U011 + (ML20072U011)
- ML20072U014 + (ML20072U014)
- ML20072U018 + (ML20072U018)
- ML20072U021 + (ML20072U021)
- 05000316/LER-1981-027, Forwards Updated LER 81-027/03X-2 + (ML20072U022)
- ML20072U029 + (ML20072U029)
- 05000316/LER-1981-027-03, Reactor Trip Occurred. Caused by Failed C-2 Capacitor & Blown Fuse.Fuse & Capacitor Replaced + (ML20072U031)
- ML20072U040 + (ML20072U040)
- ML20072U044 + (ML20072U044)
- 05000361/LER-1983-023, Forwards LER 83-023/03L-0 + (ML20072U046)
- 05000361/LER-1982-175, Forwards LER 82-175/01T-0 + (ML20072U055)
- 05000321/LER-1994-010, :on 940808,work in Control Room Panel W/Limited Access Leads to Actuation of Esf.Isolation of RWCU Believed to Be Spurious.Util Investigating Feasibility of Relocating Relay to Another Location + (ML20072U056)
- 05000361/LER-1982-175-01, /01T-0:on 820325,trip Circuit Breakers TCB-4,6,7 & 8 Failed to Trip on Undervoltage During Surveillance Test. Caused by Inadequate Lubrication Possibly Due to Excessive Preventive Maint Interval & Small Design Margin + (ML20072U063)
- 05000361/LER-1983-023-03, /03L-0:on 830227,channel B Ammonia Analyzer Failed.Caused by Instrument Drift.Channel Recalibr + (ML20072U067)
- ML20072U069 + (ML20072U069)
- ML20072U074 + (ML20072U074)
- ML20072U076 + (ML20072U076)
- ML20072U078 + (ML20072U078)
- ML20072U079 + (ML20072U079)
- NG-94-3072, Confirms Clarification of SR 4.8.C.1 Which Requires Performance of Insps & Preventive Maint on Essential Buses Listed in TS Section 3.8.C.1.List of Circuit Breakers Included in SR 4.8.B.1 Encl + (ML20072U080)
- 05000315/LER-1983-016-03, /03L-0:on 830314,control Room Air Cleanup Charcoal Filter (1-HV-ACRF) Detection Sys Found Inoperable.Caused by Failed Electronic Detection Circuit Board.Circuit Board Replaced + (ML20072U087)
- 05000361/LER-1983-019-01, /01T-0:on 830308,trip Circuit Breakers TCB-1,4 & 6 Failed to Trip on Undervoltage During Surveillance Test. Caused by Inadequate Lubrication Possibly Due to Excessive Preventive Maint Interval & Small Design Margin + (ML20072U091)
- ML20072U092 + (ML20072U092)
- ST-HL-AE-4887, Forwards Requested Summary of Calculation NC-7104,used as Basis for 940429 Proposed TS Amend,Revising TS 3.7.1.1, Turbine Cycle - Safety Valves + (ML20072U094)
- ML20072U096 + (ML20072U096)
- 05000361/LER-1983-023-01, /01T-0:on 830301,trip Circuit Breaker TCB-4 Failed to Trip on Undervoltage During Surveillance Test.Caused by Inadequate Lubrication Possibly Due to Excessive Preventive Maint Interval & Small Design Margin in Tripping Force + (ML20072U098)
- 05000364/LER-1994-001, :on 940805,main Turbine Was Manually Tripped Due to Degrading Condenser Vacuum.Caused by Equipment Failure of Local Pressure Gauge.Local Pressure Indicator Was Replaced + (ML20072U099)
- ML20072U102 + (ML20072U102)
- ML20072U104 + (ML20072U104)
- ML20072U105 + (ML20072U105)
- 05000315/LER-1983-017-03, /03L-0:on 830303,excessive Leakage Rates Noted at Upper & Lower Containment Personnel Air Lock Doors.Caused by Personnel Not Removing Grease Fittings After Lubrication. Fittings Replaced + (ML20072U106)
- ML20072U107 + (ML20072U107)
- 05000318/LER-1994-004-01, :on 940810,experienced Reactor Trip Due to Main Generator Trip.Caused by Loss of Field Relay.Replacement of Failed Components Completed & Refresher Training Provided for Operators + (ML20072U113)
- BECO-LTR-94-096, Forwards Comments on NRC Preliminary Accident Sequence Precursor Analysis (ASP) of Events on 930531 & 0910. Recommends Comments Also Be Used for Other Pilgrim Events That May Be Under Consideration as Preliminary ASPs + (ML20072U115)
- 05000315/LER-1983-018-03, /03L-0:on 830303,upper Containment Personnel Air Lock Door Leakage Rate Found Excessive.Caused by Dirt & Tape Affixed to Outer Door Seals During Equipment Installation. Dirt & Tape Removed + (ML20072U118)
- ML20072U125 + (ML20072U125)
- 05000361/LER-1983-020-03, /03L-0:on 830224,during Mode 5,latch for Door C3-67 Between Control Room & Cable Riser Gallery Discovered Jamming.Caused by Excessive Use.Emergency Maint Performed Per Special Order 83-18 + (ML20072U129)
- 05000315/LER-1983-019-03, /03L-0:on 830313,612-ft Elevation Containment Air Lock Interlock Found Inoperable.Caused by out-of-adjustment Cable.Cable Adjusted + (ML20072U133)
- 05000361/LER-1983-027-03, /03L-0:on 830224,during Mode 5,control Bldg Lobby Door C3-63 Found Unlatched & Subsequent Attempts at Latching Failed.Caused by Excessive Use.Emergency Maint Performed on Latch Per Special Order 83-18 + (ML20072U138)
- ML20072U145 + (ML20072U145)
- 05000315/LER-1983-020-03, /03L-0:on 830306,control Room Access Fire Door 412 Would Not Operate Properly.Caused by Extension Rod Pulling Loose from Door Frame Shoe.Shoe Setscrews & Rod Replaced + (ML20072U151)
- 05000315/LER-1983-021-03, /03L-0:on 830304,612-ft Elevation Containment Air Lock Interlock Found Inoperable.Caused by out-of-adjustment Cable.Cable Adjusted + (ML20072U163)
- ML20072U164 + (ML20072U164)
- ML20072U169 + (ML20072U169)