- 05000366/LER-1982-114-03, /03L-0:on 821011,with Unit Operating steady-state at 2415 Mwt,Inventory Trouble Alarm 2R44-S003 Received. Caused by Component Failure.Inverter Leg (Including Fan) Replaced,Tested & Returned to Svc + (ML20066F007)
- 0CAN118210, Provides Addl Info Re 820701 App R Exemption Requests,Per 821006 Meeting W/Nrc.Info Addresses Fire Zone Exemption Requests Being Considered for Denial by NRC + (ML20066F011)
- 05000321/LER-1980-040, Forwards Updated LER 80-040/03X-1 + (ML20066F012)
- 05000321/LER-1980-040-03, Drywell/Torus Differential Prv Opened at 1.55 Psid.Caused by Condensation Accumulation,Due to Design Problem W/Sensing Line.Design Change Relocating Sensing Lines Completed 820526 + (ML20066F014)
- ML20066F018 + (ML20066F018)
- ML20066F019 + (ML20066F019)
- ML20066F023 + (ML20066F023)
- ML20066F025 + (ML20066F025)
- ML20066F027 + (ML20066F027)
- 05000280/LER-1982-112-03, /03L-0:on 821017,one of Two Required Boric Acid Flow Paths to Core Became Unavailable & Boron Injection Tank Recirculation Terminated Due to Temporary Loss of Boric Acid Transfer Pump 1-CH-P-2A.Caused by Motor Trip + (ML20066F032)
- 05000455/LER-1990-010-11, :on 901220,severe Steam Leak Reported in Main Steam Tunnel.Caused by Improper Installation of Sample Probe During Initial Const.One Inch Nozzle Capped & Weld in Place by Temporary Alteration 90-2-66 + (ML20066F033)
- 05000366/LER-1979-015, Forwards Updated LER 79-015/03X-1 + (ML20066F034)
- ML20066F039 + (ML20066F039)
- ML20066F041 + (ML20066F041)
- 05000395/LER-1982-021, Forwards LER 82-021/03L-0.Detailed Event Analysis Encl + (ML20066F045)
- 05000366/LER-1979-015-03, Undervoltage Trip on RPS M-G Set B Found at 40-volts Ac.Caused by Undervoltage Setpoint Too Low.Design Change Completed 820409 + (ML20066F047)
- 05000219/LER-1990-015, :on 901221,two Isolation Condenser Pipe Break Sensors Found to Trip Greater than Tech Spec Setpoint.Caused by Excessive Component Drift on Switches.Switches Adjusted to Trip within Tech Spec + (ML20066F048)
- ML20066F049 + (ML20066F049)
- 05000395/LER-1982-020, Forwards LER 82-020/03L-0.Detailed Event Analysis Encl + (ML20066F052)
- 05000395/LER-1982-021-03, /03L-0:on 821011,steam Line Pressure Dropped Below Tech Spec Min.Caused by Safety Valve 2806P Inadvertently Lifting After Being Freed from stuck-closed Position.Valve & Power Range Neutron Flux High Setpoint Reset + (ML20066F055)
- 05000395/LER-1982-020-03, /03L-0:on 821011,reactor Bldg Base Mat Seismic Monitoring Instrument IYA-1780 Tested Unsatisfactorily. Caused by Battery Charger Failure Resulting in Battery Discharge.Battery Replaced & Surveillance Performed + (ML20066F058)
- 05000364/LER-1982-043, Forwards LER 82-043/01T-0 + (ML20066F062)
- 05000364/LER-1982-043-01, /01T-0:on 821028,during Attempt to Close Containment Spray Manual Isolation Valves Q2E13V001A & Q2E13V001B,valves Found Already Closed.Caused by Procedural Inadequacy & Nonconformance W/Design Drawings + (ML20066F067)
- ML20066F070 + (ML20066F070)
- 05000335/LER-1982-049, Forwards LER 82-049/03L-0 + (ML20066F078)
- 05000335/LER-1982-049-03, /03L-0:on 821018,pulse Counting Function of Control Element Assembly 41 Found Deleted.Caused by Operator Error During Setup for Moderator Temp Coefficient Test. Operators Instructed to Run Deletion Log After Readjustment + (ML20066F084)
- ML20066F115 + (ML20066F115)
- ML20066F146 + (ML20066F146)
- ML20066F149 + (ML20066F149)
- ML20066F161 + (ML20066F161)
- ML20066F181 + (ML20066F181)
- ML20066F198 + (ML20066F198)
- ML20066F200 + (ML20066F200)
- ML20066F203 + (ML20066F203)
- ML20066F217 + (ML20066F217)
- 3F0191-10, Forwards Rev 7 to Crystal River Unit 3 Fire Protection Plan. Summary of Significant Changes Listed on Encl + (ML20066F257)
- 05000302/LER-1990-019, :on 901214,incorrect Motor Installed on Valve Operator Resulting in Condition Outside Design Basis.Cause Unknown.Plant Mod Record Generated to Change Design Documents.Calculations Show Motor Acceptable + (ML20066F270)
- 05000282/LER-1990-019-01, On 901218,ventilation Filter Testing Requirements Not Being Met.Caused by Personnel Oversight in Developing Procedures.Procedure Revs Have Been Initiated to Address Need for Special Testing + (ML20066F276)
- ML20066F284 + (ML20066F284)
- 05000259/LER-1990-020-01, :on 901214,480-volt Shutdown Board 1b de-energized When Normal Feeder Breaker Tripped. Investigation Underway.Operations Personnel Notified Immediately After Event + (ML20066F287)
- 05000313/LER-1990-022-02, :on 901218,reactor Trip Initiated by RPS During Plant Heatup While Shifting Reactor Coolant Pumps.Caused by Personnel Error & Inadequate Operating Procedure.Crew Briefing Held.Procedures to Be Revised + (ML20066F288)
- ML20066F292 + (ML20066F292)
- ML20066F293 + (ML20066F293)
- ML20066F294 + (ML20066F294)
- ML20066F300 + (ML20066F300)
- ML20066F301 + (ML20066F301)
- ML20066F311 + (ML20066F311)
- ML20066F347 + (ML20066F347)
- ML20066F348 + (ML20066F348)
- ML20066F352 + (ML20066F352)
- ML20066F354 + (ML20066F354)