- 05000265/LER-1993-010-03, :on 930422,DG 1/2 Cooling Water Pump Failed to Start,As Required,During Undervoltage Functional Test.Caused by Design Deficiency in Bus 28 Breaker Close Logic. Undervoltage Contact Added in Bus 28 Logic + (ML20036B766)
- 05000458/LER-1993-004, :on 930324,deficiency Discovered in Locking of Reactor Bldg Door.Caused by Lack of Understanding of TS Requirements for Locking Airlock Door.Operator Aids Posted & Permanent Locking Device Installed on Doors + (ML20036B767)
- ML20036B768 + (ML20036B768)
- ML20036B772 + (ML20036B772)
- 05000352/LER-1993-005-01, :on 930423,missed TS 3.8.2.1 Surveillance Requirement Due to Personnel Error During Procedure Rev. Procedures Revised + (ML20036B773)
- ML20036B778 + (ML20036B778)
- ML20036B780 + (ML20036B780)
- ML20036B785 + (ML20036B785)
- ML20036B786 + (ML20036B786)
- ML20036B787 + (ML20036B787)
- ML20036B788 + (ML20036B788)
- ML20036B789 + (ML20036B789)
- ML20036B791 + (ML20036B791)
- ML20036B792 + (ML20036B792)
- ML20036B794 + (ML20036B794)
- NRC-93-0064, Forwards Request from Schedular Requirements of 10CFR50,App J,Paragraph III.A.6(b) & TS SR 4.6.1.2 Re Performance of Periodic Type a Tests,Per NRC Info Notice 85-071 + (ML20036B795)
- ML20036B797 + (ML20036B797)
- 05000298/LER-1993-018, :on 930430,potential Single Failure Vulnerability Noted W/Single Inlet Damper in Common Supply Duct.Caused by Faulty Original Design.Inlet Damper Sealed Open to Eliminate Single Failure + (ML20036B798)
- ML20036B799 + (ML20036B799)
- ML20036B801 + (ML20036B801)
- ML20036B802 + (ML20036B802)
- LIC-93-0108, Proposed Tech Specs,Changing TS 5.17 Re ODCM to Reflect 10CFR20 Re Level of Radioactive Effluent Control + (ML20036B803)
- ML20036B805 + (ML20036B805)
- ML20036B806 + (ML20036B806)
- ML20036B808 + (ML20036B808)
- ML20036B809 + (ML20036B809)
- ML20036B810 + (ML20036B810)
- ML20036B811 + (ML20036B811)
- ML20036B812 + (ML20036B812)
- ML20036B814 + (ML20036B814)
- ML20036B815 + (ML20036B815)
- ML20036B816 + (ML20036B816)
- ML20036B817 + (ML20036B817)
- ML20036B818 + (ML20036B818)
- ML20036B819 + (ML20036B819)
- ML20036B821 + (ML20036B821)
- ML20036B822 + (ML20036B822)
- ML20036B824 + (ML20036B824)
- ML20036B826 + (ML20036B826)
- ML20036B827 + (ML20036B827)
- ML20036B828 + (ML20036B828)
- ML20036B829 + (ML20036B829)
- ML20036B830 + (ML20036B830)
- ML20036B831 + (ML20036B831)
- ML20036B832 + (ML20036B832)
- ML20036B833 + (ML20036B833)
- ML20036B834 + (ML20036B834)
- ML20036B835 + (ML20036B835)
- 05000498/LER-1993-015-01, :on 930423,Tech Spec Violation Occurred Due to non-conservative Determination of Equipment Svc Time.Caused by Failure to Develop Run Hour Tracking Method.Run Times for Cleanup & Makeup Fans Monitored Individually + (ML20036B836)