- ML20036B753 + (ML20036B753)
- IR 05000213/1991099 + (ML20036B754)
- ML20036B755 + (ML20036B755)
- 05000333/LER-1993-011-01, :on 930422,determined That Monthly Diesel Fuel Oil Sample Analysis Repts for Jan & Feb 1993 Did Not Meet TS Requirement,Due to Inadequate Surveillance.Chemistry Surveillance Schedule Revised + (ML20036B757)
- 05000498/LER-1993-014, :on 900511,12,14,22 & 23,CR Envelope HVAC Sys Not Operated in Correct Mode.Caused by Increased Administrative Burden & Inadequate Tracking of Lcos. Temporary Labels Placed on Main Control Board + (ML20036B761)
- 05000298/LER-1993-016, :on 930422,during Performance of Surveillance Test on CR HVAC Sys Radiation Monitor RMV-RM-1,CR HVAC Sys Did Not Isolate & Transfer to Emergency Bypass Mode.Caused by Personnel Error.Wiring Error Corrected + (ML20036B762)
- 05000346/LER-1993-002, :on 930422,Mode 4 Entered W/Makeup Pump 1-1 Inoperable Due to Decision Not to Install Close Power Fuses for Breaker AC105.Close Power Fuses for Makeup Pump 1-1 Installed + (ML20036B763)
- 05000331/LER-1993-002, :on 930428,determined That Testing Program for Primary Containment Airlock Not in Full Compliance W/Ts Due to Different Interpretations of 1984 TS Rev Based on 1978 Submittal.Ts Rev Will Be Submitted + (ML20036B764)
- 05000285/LER-1993-005, :on 930422,determined That Incident Reportable in That SIRWT Recirculation Piping Associated w/MR-FC-83-046 Used Between Dec 1986 & 1992 Refueling Outage in Unacceptable Configuration + (ML20036B765)
- 05000265/LER-1993-010-03, :on 930422,DG 1/2 Cooling Water Pump Failed to Start,As Required,During Undervoltage Functional Test.Caused by Design Deficiency in Bus 28 Breaker Close Logic. Undervoltage Contact Added in Bus 28 Logic + (ML20036B766)
- 05000458/LER-1993-004, :on 930324,deficiency Discovered in Locking of Reactor Bldg Door.Caused by Lack of Understanding of TS Requirements for Locking Airlock Door.Operator Aids Posted & Permanent Locking Device Installed on Doors + (ML20036B767)
- ML20036B768 + (ML20036B768)
- ML20036B772 + (ML20036B772)
- 05000352/LER-1993-005-01, :on 930423,missed TS 3.8.2.1 Surveillance Requirement Due to Personnel Error During Procedure Rev. Procedures Revised + (ML20036B773)
- ML20036B778 + (ML20036B778)
- ML20036B780 + (ML20036B780)
- ML20036B785 + (ML20036B785)
- ML20036B786 + (ML20036B786)
- ML20036B787 + (ML20036B787)
- ML20036B788 + (ML20036B788)
- ML20036B789 + (ML20036B789)
- ML20036B791 + (ML20036B791)
- ML20036B792 + (ML20036B792)
- ML20036B794 + (ML20036B794)
- NRC-93-0064, Forwards Request from Schedular Requirements of 10CFR50,App J,Paragraph III.A.6(b) & TS SR 4.6.1.2 Re Performance of Periodic Type a Tests,Per NRC Info Notice 85-071 + (ML20036B795)
- ML20036B797 + (ML20036B797)
- 05000298/LER-1993-018, :on 930430,potential Single Failure Vulnerability Noted W/Single Inlet Damper in Common Supply Duct.Caused by Faulty Original Design.Inlet Damper Sealed Open to Eliminate Single Failure + (ML20036B798)
- ML20036B799 + (ML20036B799)
- ML20036B801 + (ML20036B801)
- ML20036B802 + (ML20036B802)
- LIC-93-0108, Proposed Tech Specs,Changing TS 5.17 Re ODCM to Reflect 10CFR20 Re Level of Radioactive Effluent Control + (ML20036B803)
- ML20036B805 + (ML20036B805)
- ML20036B806 + (ML20036B806)
- ML20036B808 + (ML20036B808)
- ML20036B809 + (ML20036B809)
- ML20036B810 + (ML20036B810)
- ML20036B811 + (ML20036B811)
- ML20036B812 + (ML20036B812)
- ML20036B814 + (ML20036B814)
- ML20036B815 + (ML20036B815)
- ML20036B816 + (ML20036B816)
- ML20036B817 + (ML20036B817)
- ML20036B818 + (ML20036B818)
- ML20036B819 + (ML20036B819)
- ML20036B821 + (ML20036B821)
- ML20036B822 + (ML20036B822)
- ML20036B824 + (ML20036B824)
- ML20036B826 + (ML20036B826)
- ML20036B827 + (ML20036B827)
- ML20036B828 + (ML20036B828)
- ML20036B829 + (ML20036B829)