Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20004D582 + (ML20004D582)
- 05000366/LER-1981-048, Forwards LER 81-048/03L-0 + (ML20004D584)
- ML20004D585 + (ML20004D585)
- ML20004D586 + (ML20004D586)
- 05000312/LER-1981-027, Forwards LER 81-027/03L-0.Detailed Event Analysis Also Submitted + (ML20004D587)
- 05000318/LER-1981-004, Forwards LER 81-004/03L-0 + (ML20004D589)
- ML20004D590 + (ML20004D590)
- ML20004D591 + (ML20004D591)
- ML20004D592 + (ML20004D592)
- 05000312/LER-1981-027-03, /03L-0:on 810502,RBS Pump Breaker 3A09 Tripped When Attempting Start from Control Room.Cause Unknown.Trip Reset + (ML20004D593)
- 05000339/LER-1981-038, Forwards LER 81-038/03L-0 + (ML20004D594)
- ML20004D595 + (ML20004D595)
- 05000318/LER-1981-004-03, /03L-0:on 810204, While Conducting Preventive Maint,Shutdown Cooling Flow Lost.Caused by Procedure Not Containing Sufficient Info.Flow Lost Due to de-energized Vital Ac Bus Causing Valve to Shut.Procedure Revised + (ML20004D598)
- ML20004D599 + (ML20004D599)
- 05000366/LER-1981-048-03, /03L-0:on 810527,while Operating at 99% Power Control Rod Scram Accumulator 26-47 Found Inoperative.Caused by Leakage in Instrument Block Valve III of Accumulator. Accumulator Recharged Per HNP-2-1425 Procedure + (ML20004D600)
- ML20004D601 + (ML20004D601)
- 05000339/LER-1981-038-03, /03L-0:on 810505,during Mode 1 Operation,Channel III Feedwater Flow Indication for Loop 2 Failed High.Caused by Failure of Loop Multiplier/Divider/Square Root Card.Card Replaced & Channel Recalibr & Returned to Svc + (ML20004D602)
- ML20004D604 + (ML20004D604)
- ML20004D606 + (ML20004D606)
- 05000346/LER-1981-028, Forwards LER 81-028/03L-0 + (ML20004D607)
- ML20004D608 + (ML20004D608)
- 05000339/LER-1981-040, Forwards LER 81-040/03L-0 + (ML20004D609)
- ML20004D610 + (ML20004D610)
- 05000346/LER-1981-028-03, /03L-0:on 810505,log Review Showed That Liquid Release Had Been Made While Radiation Monitors Re 1878A & B Were Inoperable Due to Testing Date Being Exceeded.Caused by Personnel Error.Personnel Will Be Counseled + (ML20004D615)
- 05000317/LER-1981-003, Forwards LER 81-003/03L-0 + (ML20004D616)
- ML20004D617 + (ML20004D617)
- 05000339/LER-1981-040-03, /03L-0:on 810508,axial Flux Difference Deviated Greater than 5% from Target for 28 Penalty Minutes During Rampdown from Full Power for Scheduled Outage.Caused by Control Rods Being High in Core.Rods Inserted + (ML20004D619)
- ML20004D620 + (ML20004D620)
- ML20004D621 + (ML20004D621)
- 05000317/LER-1981-003-03, /03L-0:on 810217,engineered Safety Features Actuation Sys Channel 2D 12 Steam Generator Pressure Isolator Found Out of Spec.Caused by Transmation Isolator w/non-liner Output.Isolator Replaced + (ML20004D623)
- PNO-IV-81-014, on 810602,four Individuals Investigating Source of Unidentified Primary Sys Leakage in Containment Bldg Received Possible Overexposure of Neutrons.Exposure May Be Incorrect.Neutron TLD Calibr Is Under Investigation + (ML20004D624)
- ML20004D626 + (ML20004D626)
- 05000339/LER-1981-041, Forwards LER 81-041/03L-0 + (ML20004D627)
- ML20004D628 + (ML20004D628)
- 05000318/LER-1981-009, Forwards LER 81-009/03L-0 + (ML20004D629)
- ML20004D630 + (ML20004D630)
- ML20004D631 + (ML20004D631)
- 05000296/LER-1981-019-03, During Shutdown,When HPCI Sys Initiated,Upper & Lower HPCI Gland Seal Condenser Head Gaskets Were Blown.Caused by Overpressurization of Tube Side of HPCI Gland Seal Condenser.Gaskets Replaced + (ML20004D635)
- 05000339/LER-1981-041-03, /03L-0:on 810512,reservoir of Snubber 2-RC-HSS-463-1 Found Empty of Fluid.Caused by Hairline Crack in Lexan Reservoir Tube.Snubber Replaced W/Spare + (ML20004D638)
- 05000318/LER-1981-009-03, /03L-0:on 810330,during Normal Power Operation, Motor Operated Isolation Valve in Saltwater Sys Would Not Operate Electrically.Caused by Tripped Overload Devices on Phase a & C.Devices Reset + (ML20004D639)
- ML20004D640 + (ML20004D640)
- TXX-3138, Final Deficiency Rept Re Violation of Piping Min Wall Thickness,Initially Reported on 790522.Revisions to Fabrication & Documents Completed.Final Stress Analyses Are Targeted for Completion Prior to Hot Functional Testing + (ML20004D641)
- ML20004D643 + (ML20004D643)
- ML20004D644 + (ML20004D644)
- ML20004D645 + (ML20004D645)
- 05000259/LER-1981-023, Forwards LER 81-023/03L-0 + (ML20004D646)
- ML20004D647 + (ML20004D647)
- ML20004D650 + (ML20004D650)
- 05000259/LER-1981-023-03, /03L-0:on 810510,damaged Cable Heat Tray Detector Caused False Alarm Which Could Have Masked Other Alarms. Probable Cause of Damaged Heat Detector Attributed to Cable Pulling Crew.Heat Detector Replaced & Functionally Tested + (ML20004D654)
- 05000267/LER-1981-033, Forwards LER 81-033/03L-0.Detailed Event Analysis Encl + (ML20004D655)
- ML20004D656 + (ML20004D656)