- ML20003C325 + (ML20003C325)
- ML20003C326 + (ML20003C326)
- 05000277/LER-1981-008-03, /03L-0:on 810127,containment Isolation Valves SV-2978C & SV-2671A in Sample Lines to Oxygen Analyzer Failed to Close Fully.Caused by Sticking Plunger Assemblies. Valves Cleaned,Reassembled & Leak Tested on 810204 + (ML20003C328)
- ML20003C329 + (ML20003C329)
- 05000327/LER-1980-069, Has Been Cancelled + (ML20003C330)
- 05000278/LER-1981-004-03, /03L-0:on 810126,reactor Pressure Switch PS-3-2-3-102C,which Trips Recirculation Pump a Found to Exceed Tech Spec Limit.Caused by Setpoint Drift of Static-O-Ring Pressure Switch.Instrument Recalibr + (ML20003C331)
- 05000312/LER-1980-020, Has Been Cancelled + (ML20003C332)
- 05000277/LER-1981-014-03, /03L-0:on 810131,Leeds & Northrup Model W multi-point Temp Recorder TR-2-10-131 Found Not Recording Suppression Chamber Water Temp Per Tech Spec.Caused by Bound Drive Motor.Instrument Repaired & Returned to Svc on 810202 + (ML20003C333)
- 05000333/LER-1981-017, Forwards LER 81-017/03L-0 + (ML20003C334)
- ML20003C335 + (ML20003C335)
- 05000327/LER-1980-034, Has Been Cancelled + (ML20003C336)
- ML20003C337 + (ML20003C337)
- 05000333/LER-1981-017-03, /03L-0:on 810207,average Power Range Monitors a & E Downscale Trips Found Set at Less than 2.5/125,in Violation of Tech Spec 3.1-1.Possibly Caused by Instrument Drift.Downscale Trips Adjusted + (ML20003C338)
- ML20003C339 + (ML20003C339)
- ML20003C340 + (ML20003C340)
- ML20003C341 + (ML20003C341)
- ML20003C342 + (ML20003C342)
- 05000333/LER-1981-016, Forwards LER 81-016/03L-0 + (ML20003C343)
- ML20003C344 + (ML20003C344)
- 05000333/LER-1981-016-03, /03L-0:on 810203,reactor Core Isolation Cooling Made Inoperable to Repair Thermocouple Connection in Subsys. Caused by Thermocouple Failure Due to Normal Wear & Tear. Connection Repaired + (ML20003C345)
- ML20003C346 + (ML20003C346)
- 05000302/LER-1981-007, Forwards LER 81-007/03L-0 + (ML20003C347)
- ML20003C348 + (ML20003C348)
- 05000302/LER-1981-007-03, /03L-0:on 810126,radiation Monitor RM-A5 Failed to Restart After Filter Change.Caused by Blown Fuse.Fuse Replaced + (ML20003C349)
- ML20003C350 + (ML20003C350)
- ML20003C351 + (ML20003C351)
- ML20003C352 + (ML20003C352)
- 05000316/LER-1980-035, Forwards Updated LER 80-035/03X-1 + (ML20003C353)
- ML20003C354 + (ML20003C354)
- ML20003C355 + (ML20003C355)
- ML20003C356 + (ML20003C356)
- ML20003C357 + (ML20003C357)
- ML20003C358 + (ML20003C358)
- ML20003C359 + (ML20003C359)
- ML20003C361 + (ML20003C361)
- ML20003C362 + (ML20003C362)
- ML20003C364 + (ML20003C364)
- ML20003C365 + (ML20003C365)
- ML20003C367 + (ML20003C367)
- ML20003C368 + (ML20003C368)
- ML20003C370 + (ML20003C370)
- ML20003C371 + (ML20003C371)
- ML20003C372 + (ML20003C372)
- ML20003C373 + (ML20003C373)
- ML20003C374 + (ML20003C374)
- ML20003C375 + (ML20003C375)
- ML20003C376 + (ML20003C376)
- ML20003C378 + (ML20003C378)
- ML20003C379 + (ML20003C379)
- ML20003C380 + (ML20003C380)
- ML20003C381 + (ML20003C381)