- ML19338F142 + (ML19338F142)
- 05000368/LER-1980-058, Forwards Updated LER 80-058/03X-1 + (ML19338F143)
- ML19338F144 + (ML19338F144)
- 05000325/LER-1980-068-03, /03L-0:on 800901,during rod-block Monitor Blocks, a rod-block Monitor Trip Actuated at Less than Required Setpoint.Caused by Instrument Drift.Monitors Recalbr + (ML19338F145)
- 05000313/LER-1980-033-03, /03L-0:on 800906,during Normal Cooldown Operations,Rcs Makeup Block Valve Failed to Close Fully on Command.Caused by High Differential Across Valve,Resulting in Operation of Close Torque Limit Switch + (ML19338F147)
- 05000301/LER-1980-008-01, /01T-0:on 800912,following Trip from Full Power, Main Steam Stop Valve B Failed to Close Upon Receiving Close Signal.Caused by Deposit Buildup on Valve Shaft &/Or Hardening of Gland Packing + (ML19338F148)
- ML19338F149 + (ML19338F149)
- 05000313/LER-1980-034, Forwards LER 80-034/03L-0 + (ML19338F150)
- ML19338F151 + (ML19338F151)
- 05000325/LER-1980-071, Forwards LER 80-071/03L-0 + (ML19338F153)
- ML19338F154 + (ML19338F154)
- ML19338F155 + (ML19338F155)
- 05000368/LER-1980-058-03, During Mode 1 Operation, Ceac 2 Failed on Two Separate Occasions.Cause Undetermined. Ceac 2 Reinitialized Per Sys Periodic Test Procedure.All Failure Indications Returned to Normal + (ML19338F157)
- ML19338F158 + (ML19338F158)
- ML19338F161 + (ML19338F161)
- ML19338F162 + (ML19338F162)
- 05000313/LER-1980-034-03, /03L-0:on 800905,during Normal Operation,Small Primary to Secondary Leak Developed from Steam Generator E24A.Caused by Flow Induced Vibration Crack in Tube 74-2. Tube Was Plugged & Unit Returned to Svc + (ML19338F163)
- 05000339/LER-1980-057, Forwards LER 80-057/03L-0 + (ML19338F164)
- ML19338F166 + (ML19338F166)
- 05000325/LER-1980-071-03, /03L-0:on 800903,core Auxiliary Cooling Monitors 1260,1261,1262 & 1263 Were Not Working W/Suction Valves to Each Monitor from Drywell in Closed Position.Caused by Open Feeder Breaker.Breaker Closed & Monitors Returned to Nor + (ML19338F167)
- ML19338F168 + (ML19338F168)
- ML19338F169 + (ML19338F169)
- ML19338F172 + (ML19338F172)
- DCL-19-077, Post-Shutdown Decommissioning Activities Report + (ML19338F173)
- 05000327/LER-1980-088, Forwards LER 80-088/03L-0 + (ML19338F174)
- ML19338F175 + (ML19338F175)
- 05000324/LER-1980-060, Forwards LER 80-060/03L-0 + (ML19338F176)
- ML19338F177 + (ML19338F177)
- 05000339/LER-1980-057-03, /03L-0:on 800908,w/unit in Mode 3,individual Rod Position Indication for Rod G-9 in Shutdown Bank B Deviated from Group Demand Position by Greater than 12 Steps.Caused by Instrument Drift.Indicator Recalibr + (ML19338F178)
- 05000327/LER-1980-088-03, /03L-0:on 800902,util Was Advised That Insulated Control Cable to Ms Valves,To Afwpt,Afw SG Level Control Valves & MFW Isolation Valves Required Replacement.Caused by Failure to Meet Environ Temp Qualifications + (ML19338F179)
- ML19338F180 + (ML19338F180)
- 05000339/LER-1980-055, Forwards LER 80-055/03L-0 + (ML19338F182)
- ML19338F183 + (ML19338F183)
- 05000339/LER-1980-055-03, /03L-0:on 800905,results of Periodic Valve Inservice Test Revealed Excessive Leakage Past 2-SI-70. Caused by Corroded Seating Plug.Valve Replaced & Tested Satisfactorily + (ML19338F184)
- ML19338F185 + (ML19338F185)
- ML19338F188 + (ML19338F188)
- 05000348/LER-1980-053, Forwards LER 80-053/03L-0 + (ML19338F189)
- ML19338F190 + (ML19338F190)
- 05000313/LER-1980-031, Forwards LER 80-031/03L-0 + (ML19338F191)
- ML19338F192 + (ML19338F192)
- ML19338F193 + (ML19338F193)
- ML19338F195 + (ML19338F195)
- 05000348/LER-1980-053-03, /03L-0:on 800909,during Surveillance Testing, Containment Spray Automatic Actuation Logic Declared Inoperable.Caused by Integrated Circuit Failure.Circuit Card Replaced & Logic Returned to Svc + (ML19338F196)
- 05000313/LER-1980-031-03, /03L-0:on 800827,during Monthly Surveillance Test, Excessive Smoke Observed in Emergency Diesel Generator Turbo Charger Exhaust Flange.Caused by Exhaust Gas Contact W/ Insulation,Due to Loose Bolts & Gasket + (ML19338F198)
- ML19338F199 + (ML19338F199)
- ML19338F201 + (ML19338F201)
- ML19338F202 + (ML19338F202)
- ML19338F203 + (ML19338F203)
- ML19338F205 + (ML19338F205)
- ML19338F206 + (ML19338F206)
- ML19338F207 + (ML19338F207)