- ML19331D770 + (ML19331D770)
- 05000338/LER-1980-068, Forwards LER 80-068/03L-0 + (ML19331D771)
- ML19331D772 + (ML19331D772)
- ML19331D773 + (ML19331D773)
- 05000259/LER-1980-057, Forwards LER 80-057/03L-0 + (ML19331D774)
- ML19331D775 + (ML19331D775)
- ML19331D776 + (ML19331D776)
- 05000338/LER-1980-068-03, /03L-0:on 800801,during Full Power,Electrical Load Discovered as Having Been Added to 1H Emergency Bus W/O Approved Jumper.Caused by Improper Administrative Controls. Load Isolated from Emergency Bus & Personnel Reinstructed + (ML19331D777)
- ML19331D778 + (ML19331D778)
- ML19331D779 + (ML19331D779)
- 05000259/LER-1980-057-03, /03L-0:on 800730,during Past Two Refueling Outages,Required Tech Spec 4.6.G.6 Testing Was Not Performed.Caused by Testing Not Being Identified as Outage Work Item.Insp Will Be Completed at Next Refueling Outage + (ML19331D780)
- 05000339/LER-1980-043, Forwards LER 80-043/03L-0 + (ML19331D781)
- ML19331D782 + (ML19331D782)
- ML19331D783 + (ML19331D783)
- ML19331D784 + (ML19331D784)
- ML19331D785 + (ML19331D785)
- 05000339/LER-1980-043-03, /03L-0:on 800814,during Mode 5 Operation, Pressurizer Power Relief Valve Declared Inoperable When Nitrogen Gas Supply Required for Overpressure Protection Dropped Below 1,775 Psig.Caused by Low Nitrogen Pressure + (ML19331D786)
- ML19331D787 + (ML19331D787)
- ML19331D788 + (ML19331D788)
- 05000339/LER-1980-044, Forwards LER 80-044/03L-0 + (ML19331D790)
- ML19331D791 + (ML19331D791)
- ML19331D792 + (ML19331D792)
- ML19331D793 + (ML19331D793)
- ML19331D794 + (ML19331D794)
- 05000339/LER-1980-044-03, /03L-0:on 800730,during Mode 2 Generation at 3% Power Bypass Feedwater Regulator Valve Failed Open,Causing High Water Level in Steam Generator A.Caused by Valve Operator Failure,Possibly Caused by Water in Air Line + (ML19331D795)
- ML19331D796 + (ML19331D796)
- ML19331D799 + (ML19331D799)
- 05000339/LER-1980-046, Forwards LER 80-046/03L-0 + (ML19331D800)
- ML19331D801 + (ML19331D801)
- 05000293/LER-1980-039, Forwards LER 80-039/01T-0 + (ML19331D802)
- ML19331D803 + (ML19331D803)
- 05000296/LER-1980-028, Forwards LER 80-028/03L-0 + (ML19331D804)
- 05000293/LER-1980-039-01, /01T-0:on 800820,calibr Techniques for Limiting Safety Sys Setting & for Average Power Range Monitor Found to Be Nonconservative.Cause Unstated.Interim Administrative Limits Established Pending Final Guidelines + (ML19331D806)
- 05000302/LER-1980-033, Forwards LER 80-033/03L-0 + (ML19331D807)
- ML19331D808 + (ML19331D808)
- ML19331D809 + (ML19331D809)
- ML19331D810 + (ML19331D810)
- 05000293/LER-1980-038, Forwards LER 80-038/01T-0 + (ML19331D811)
- ML19331D812 + (ML19331D812)
- 05000338/LER-1980-061, Forwards LER 80-061/01X-1 + (ML19331D813)
- ML19331D814 + (ML19331D814)
- 05000293/LER-1980-038-01, /01T-0:on 800818,mode Switch in Shutdown Trip Function of Reactor Protection Sys Failed When B Vital Motor Generator Set Tripped.Caused by Relay 5A-K16B Being Energized & Relay 5A-K17B Being de-energized + (ML19331D815)
- 05000339/LER-1980-046-03, /03L-0:on 800818,while Heating in Mode 3 Operation,Position Indication for Control Rod G-9 Greater than 12 Steps from Demand Position.Caused by Voltage Drift in Signal Conditioning Card.Recalibr & Functional Test Done + (ML19331D816)
- 05000302/LER-1980-033-03, /03L-0:on 800803,following Routine Sampling of Core Flood Tank A,Sample Isolation Valve CFV-11 Failed to Close.Caused by Failed Contact Rotor in Limitorque Operator. Contact Rotor 2 Replaced & Declared Operable + (ML19331D817)
- 05000293/LER-1980-043, Forwards LER 80-043/04L-0 + (ML19331D818)
- ML19331D819 + (ML19331D819)
- 05000338/LER-1980-071, Forwards LER 80-071/01T-0 + (ML19331D820)
- 05000338/LER-1980-061-01, /01X-1:on 800708,S&W Review Indicated That Under Accident Conditions,Auxiliary Feedwater Pump 1-FW-P-3B May Not Be Able to Function as Designed.Cause Unknown.Testing on Pump Will Be Conducted to Determine Pump Flow Capacity + (ML19331D822)
- 05000339/LER-1980-045, Forwards LER 80-045/03L-0 + (ML19331D823)
- ML19331D824 + (ML19331D824)
- 05000293/LER-1980-043-04, /04L-0:on 800801,conductivity on Outlet of Demineralizer Increased Rapidly After Placing D Condensate in Svc.Caused by Lateral Backing Out & Allowing Media to Enter Process + (ML19331D825)