- 05000249/LER-1980-009-03, /03L-0:on 800306,during Refueling Outage,While Performing LPCI Logic Tests,Injection Valve Mo 3-1501-22A Failed to Open.Caused by Loose Wire on Terminal Block in MCC-38-7 Due to Stripped Brass Screw + (ML19322E806)
- 05000295/LER-1980-010, Forwards LER 80-010/03L-0 + (ML19322E807)
- 05000295/LER-1980-010-03, /03L-0:on 800219,during Normal Operation,Component Cooling Liquid Rad Monitor 1RE-0017 Read High Alarm Intermittently.Caused by Corroded Detector Contact Pins Due to Condensation.Pin Replaced & More Insulation Installed + (ML19322E809)
- ML19322E811 + (ML19322E811)
- 05000302/LER-1980-013, Forwards LER 80-013/04L-0 + (ML19322E813)
- ML19322E814 + (ML19322E814)
- ML19322E815 + (ML19322E815)
- ML19322E816 + (ML19322E816)
- ML19322E817 + (ML19322E817)
- ML19322E818 + (ML19322E818)
- ML19322E819 + (ML19322E819)
- ML19322E820 + (ML19322E820)
- 05000302/LER-1980-013-04, /04L-0:on 800304,more than Two Std Deviations Were Discovered Between Preoperational Study & Operational Study in Metabolic Function of Discharge Salt Marshes.Possibly Caused by Natural or Seasonal Variations + (ML19322E821)
- 05000366/LER-1980-027, Forwards LER 80-027/03L-0 + (ML19322E822)
- ML19322E823 + (ML19322E823)
- ML19322E824 + (ML19322E824)
- ML19322E825 + (ML19322E825)
- 05000366/LER-1980-027-03, /03L-0:on 800315,while Performing,Plant Svc Water Pump Auto Function Operability Surveillance,Isolation Valve 2P41-F316A Failed to Actuate to Isolation Position Upon Signal.Caused by Instrument Failure + (ML19322E826)
- ML19322E827 + (ML19322E827)
- ML19322E829 + (ML19322E829)
- ML19322E830 + (ML19322E830)
- ML19322E831 + (ML19322E831)
- ML19322E832 + (ML19322E832)
- 05000368/LER-1980-013, Forwards LER 80-013/03L-0 + (ML19322E833)
- ML19322E834 + (ML19322E834)
- 05000366/LER-1980-020, Forwards LER 80-020/03L-0 + (ML19322E835)
- ML19322E836 + (ML19322E836)
- 05000266/LER-1980-002-01, /01T-0:on 800311,during shutdown,800 Psi secondary-to-primary Hydrostatic Leak Test of B Steam Generator Revealed Tube R23C44 Leaking,Tube R8C37 Wet & Plug End R23C50 Wet.Tube Holes Will Be Weld Plugged + (ML19322E837)
- ML19322E838 + (ML19322E838)
- 05000368/LER-1980-013-03, /03L-0:on 800229,during Mode 5 Operation,Reactor Cooling Sys Chloride Concentration Found to Be Approx 0.5 Ppm,Violating Tech Specs.Probably Caused by Batch Contaminated During Maint on Safety Injection Check Valve + (ML19322E839)
- 05000366/LER-1980-020-03, /03L-0:on 800229,during Normal Operation,While Performing HPCI Exhaust Diaphragm Pressure Switch Surveillance,Two Switches Exceeded Tech Specs.Caused by Instrument Drift.Switches Recalibr + (ML19322E840)