- 05000338/LER-1980-027-99, /99X-0:on 800220,during Reactor Trip from 100% Power,Abnormal Noise in C Steam Generator Detected by Installed Loose Parts Monitoring Sys.Cause Unknown. Westinghouse Personnel Called in to Conduct Investigation + (ML19309H136)
- 05000321/LER-1980-039, Forwards LER 80-039/01T-0 + (ML19309H137)
- ML19309H138 + (ML19309H138)
- 05000321/LER-1980-038, Forwards LER 80-038/03L-0 + (ML19309H139)
- ML19309H140 + (ML19309H140)
- 05000321/LER-1980-039-01, /01T-0:on 800411,discovered That Psw & RHR-SW Pump Motor Cooling Water Supply Did Not Meet Single Failure Criterion.Caused by Initial Design Not Specifying Divisional Water Cooling Water Supply to Pumps + (ML19309H141)
- 05000346/LER-1980-032, Forwards LER 80-032/03L-0 + (ML19309H142)
- ML19309H143 + (ML19309H143)
- 05000321/LER-1980-038-03, /03L-0:on 800327,while Performing Reactor Protection Sys Surveillance HNP-1-3456,output Breaker of a Reactor Motor Generator Tripped & Would Not Reset.Caused by Mechanical Reset Latch Failing to Reset.Breaker Replaced + (ML19309H144)
- 05000338/LER-1980-038, Forwards LER 80-038/03L-0 + (ML19309H145)
- ML19309H146 + (ML19309H146)
- 05000346/LER-1980-032-03, /03L-0:on 800406,inboard Bearing Oil Sight Glass of Containment Spray Pump 1-2 Found Shattered.Pump Declared Inoperable.Oil Sight Glass Accidentally Broken by Const Activities in Area.Sight Glass Replaced & New Oil Added + (ML19309H147)
- ML19309H148 + (ML19309H148)
- 05000338/LER-1980-038-03, /03L-0:on 800409,during Power Escalation,Axial Flux Difference Deviated Greater than Limit for three-minute Duration.Caused by Overinsertion of Control Rods Resulting from Continued Dilution During Hold in Power Escalation + (ML19309H149)
- 05000368/LER-1980-018, Forwards LER 80-018/03L-0 + (ML19309H150)
- ML19309H151 + (ML19309H151)
- ML19309H152 + (ML19309H152)
- ML19309H157 + (ML19309H157)
- ML19309H159 + (ML19309H159)
- ML19309H160 + (ML19309H160)
- PNO-IV-80-017, site QA Supervisor Notified Resident Inspector of Mechanical Electrical Auxiliary Bldg Tilt.Possibly Caused by Heavier Loading of North End During Const.Condition Will Probably Be Corrected When Uniform Loading Is Achieved + (ML19309H161)
- ML19309H165 + (ML19309H165)
- ML19309H166 + (ML19309H166)
- 05000321/LER-1980-033, Forwards LER 80-033/03L-0 + (ML19309H167)
- ML19309H168 + (ML19309H168)
- ML19309H169 + (ML19309H169)
- 05000321/LER-1980-033-03, /03L-0:on 800402,while Inspecting CST Access Stairway,Cold Joint Between Original Base Slab & Added Slab for Retaining Walls Lacked Watertight Seal.Caused by Const Oversight.Maint Request Issued + (ML19309H170)
- ML19309H171 + (ML19309H171)
- ML19309H172 + (ML19309H172)
- ML19309H174 + (ML19309H174)
- ML19309H175 + (ML19309H175)
- 05000366/LER-1980-039, Forwards LER 80-039/01X-1 + (ML19309H176)
- ML19309H177 + (ML19309H177)
- ML19309H178 + (ML19309H178)
- ML19309H179 + (ML19309H179)
- ML19309H180 + (ML19309H180)
- IR 05000315/1980005 + (ML19309H181)
- ML19309H182 + (ML19309H182)
- ML19309H183 + (ML19309H183)
- ML19309H184 + (ML19309H184)
- 05000366/LER-1980-039-01, /01X-1:on 800411,during Normal Operation,Psw & RHR-SW Pump Motor Cooling Water Supply Did Not Meet Single Failure Criterion.Caused by Design Not Specifying Divisional Cooling Water Supply to Pumps + (ML19309H185)
- ML19309H186 + (ML19309H186)
- ML19309H187 + (ML19309H187)
- ML19309H188 + (ML19309H188)
- ML19309H189 + (ML19309H189)
- ML19309H190 + (ML19309H190)
- 05000366/LER-1980-046, Forwards LER 80-046/03L-0 + (ML19309H191)
- ML19309H192 + (ML19309H192)
- 05000366/LER-1980-046-03, /03L-0:on 800404,during 18-month Surveillance Procedure HNP2-3832,loss of Sys Pressure Was Simulated on Diesel Generator 2C & Bus 2G.Generator Started But Did Not Tie to Bus.Caused by Personnel Error + (ML19309H193)
- ML19309H194 + (ML19309H194)