Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19305C033 + (ML19305C033)
- 05000325/LER-1980-006, Forwards LER 80-006/03L-0 + (ML19305C034)
- ML19305C035 + (ML19305C035)
- ML19305C036 + (ML19305C036)
- 05000267/LER-1980-008-03, /03L-0:on 800219,during Routine Surveillance Testing,Setpoints for Low Flow on One Dewpoint Moisture Monitor & for Fixed low-low Flow on Another Monitor Found Less than Min Acceptable.Caused by Instrument Calibr Drift + (ML19305C037)
- 05000325/LER-1980-006-03, /03L-0:on 800225,while Working on Trouble Ticket Re Position Indication for RIP Valve 49B,discovered Valve Not Closing Fully When Given Closing Signal.No Cause Stated. Valve Will Be Repaired During 1980 Refueling Outage + (ML19305C038)
- ML19305C039 + (ML19305C039)
- ML19305C040 + (ML19305C040)
- ML19305C042 + (ML19305C042)
- ML19305C043 + (ML19305C043)
- ML19305C046 + (ML19305C046)
- ML19305C047 + (ML19305C047)
- ML19305C048 + (ML19305C048)
- ML19305C049 + (ML19305C049)
- ML19305C050 + (ML19305C050)
- ML19305C051 + (ML19305C051)
- ML19305C053 + (ML19305C053)
- ML19305C054 + (ML19305C054)
- ML19305C055 + (ML19305C055)
- ML19305C056 + (ML19305C056)
- 05000267/LER-1980-006, Forwards LER 80-006/03L-0 + (ML19305C058)
- ML19305C059 + (ML19305C059)
- ML19305C060 + (ML19305C060)
- 05000267/LER-1980-006-03, /03L-0:on 800218,w/reactor at Less than 2% Power, Vent Stack Snubber VSS-117 Was Inoperable & Degraded Mode of Tech Spec LCO 4.3.10 Existed.Caused by Taking Reactor Critical W/Vent Stack Snubber Out of Svc for Maint + (ML19305C061)
- 05000289/LER-1980-004, Forwards LER 80-004/01T-0 + (ML19305C062)
- ML19305C063 + (ML19305C063)
- ML19305C064 + (ML19305C064)
- ML19305C065 + (ML19305C065)
- 05000289/LER-1980-004-01, /01T-0:on 800306,during Piping Reanalysis,Errors Were Discovered in Seismic Analysis of Common Decay Heat Suction Piping.Caused by Analysis Error.Affected Piping Seismic Analysis Will Be Corrected & Hardware Changes Made + (ML19305C066)
- ML19305C067 + (ML19305C067)
- ML19305C068 + (ML19305C068)
- ML19305C069 + (ML19305C069)
- 05000324/LER-1980-035, Forwards LER 80-035/03L-0 + (ML19305C070)
- ML19305C071 + (ML19305C071)
- 05000267/LER-1980-007, Forwards LER 80-007/03L-0 + (ML19305C072)
- ML19305C073 + (ML19305C073)
- ML19305C074 + (ML19305C074)
- ML19305C075 + (ML19305C075)
- 05000324/LER-1980-035-03, /03L-0:on 800219,during Normal Plant Operation, Operator Noticed Containment Atmosphere Monitor CAC-AT-1263 Would Not Run Due to Low Flow.Caused by Faulty Monitor. Monitor Will Be Repaired Before Return to Power + (ML19305C077)
- 05000320/LER-1980-005-01, /01L-0:on 800218,during Mode 5 Operation,B Emergency Diesel Generator Was Out of Svc Which Violated 800215 Newly Issued Interim Recovery Tech Specs.Caused by Change in Tech Specs for Emergency Diesel Generators + (ML19305C078)
- ML19305C080 + (ML19305C080)
- ML19305C081 + (ML19305C081)
- ML19305C082 + (ML19305C082)
- ML19305C083 + (ML19305C083)
- ML19305C085 + (ML19305C085)
- ML19305C086 + (ML19305C086)
- ML19305C087 + (ML19305C087)
- ML19305C088 + (ML19305C088)
- ML19305C090 + (ML19305C090)
- ML19305C091 + (ML19305C091)
- ML19305C093 + (ML19305C093)