THE FORT ST. VRAIN INITIAL APPROACH TO POWER TESTS (B-SERIES)
INIERIM REPORT 14 Report for Period Ending February 22, 1980
\\.
Interim Report 8 covering the 90 day period ending August 22, 1978, re-ported the completion of all tests up to 70% of plant load.
Since the Nuclear Regulatory Commission did not release the plant for operation at power levels in excess of 70%, no further Initial Approach to Pcwer Tests were performed during the 90 days ending February 22, 1980.
The Fort St. Vrain Nuclear Generating Station was accepted for commercial operation at 70% power by Public Service Company of Colorado on July 1,1979.
Future interim reports will report the results of any startup tests at power levels above 70%.
a w
,,,_