- ML19259C057 + (ML19259C057)
- ML19259C058 + (ML19259C058)
- ML19259C059 + (ML19259C059)
- ML19259C060 + (ML19259C060)
- ML19259C061 + (ML19259C061)
- ML19259C062 + (ML19259C062)
- TXX-2996, Forwards Affidavit of Svc for Amend 6 to FSAR + (ML19259C063)
- ML19259C064 + (ML19259C064)
- 05000293/LER-1979-018, Forwards LER 79-018/01T-1 + (ML19259C065)
- ML19259C066 + (ML19259C066)
- 05000293/LER-1979-018-01, /01T-1: on 790519,recirculation Pump Started W/Delta Temp Between Loops Greater than 50 F & Reactor Coolant Temp Greater than 212 F.Caused by Failure to Follow Station Operating Procedures & Temp Monitors + (ML19259C067)
- 05000237/LER-1979-029-03, /03L-0 on 790508:DIS 1400-3,pressure Switch 2-1430-1466D Failed to Trip.Caused by Sticky Plunger in Pressure Switch.Switch Removed,Cleaned & Reset to Trip at 94.5 Psig Increasing + (ML19259C068)
- ML19259C069 + (ML19259C069)
- ML19259C071 + (ML19259C071)
- 05000309/LER-1979-012, Forwards LER 79-012/01T-0 + (ML19259C072)
- 05000309/LER-1979-012-01, /01T-0 on 790524:reactor Protection Sys Low Pressure Trip Bistables in Error Set at 415 Psig.Caused by Incorrectly Transposing Data Transmitter Calibr Sheets to Procedure.Calibr Sheets & Procedures Being Revised + (ML19259C074)
- ML19259C075 + (ML19259C075)
- ML19259C076 + (ML19259C076)
- ML19259C077 + (ML19259C077)
- ML19259C078 + (ML19259C078)
- ML19259C079 + (ML19259C079)
- ML19259C080 + (ML19259C080)
- ML19259C081 + (ML19259C081)
- ML19259C082 + (ML19259C082)
- ML19259C083 + (ML19259C083)
- 05000250/LER-1979-014, Forwards LER 79-014/03L-0 + (ML19259C084)
- ML19259C085 + (ML19259C085)
- ML19259C086 + (ML19259C086)
- ML19259C087 + (ML19259C087)
- ML19259C088 + (ML19259C088)
- ML19259C089 + (ML19259C089)
- ML19259C090 + (ML19259C090)
- 05000250/LER-1979-014-03, /03L-0 on 790424:ready to Start Light on B Emergency Diesel Generator Engine Control Panel Failed. Caused by Vibration of Lamp Socket.Tests Under Way to Determine If Neon Unit Would Be Better Suited + (ML19259C092)
- ML19259C093 + (ML19259C093)
- ML19259C094 + (ML19259C094)
- ML19259C095 + (ML19259C095)
- ML19259C096 + (ML19259C096)
- 05000250/LER-1979-015, Forwards LER 79-015/03L-0 + (ML19259C097)
- ML19259C098 + (ML19259C098)
- ML19259C099 + (ML19259C099)
- ML19259C100 + (ML19259C100)
- ML19259C101 + (ML19259C101)
- 05000250/LER-1979-015-03, /03L-0 on 790426:B Emergency Diesel Generator Failed Loading Acceptance Criteria.Caused by Cracked half-inch Nipple to Fuel Pump Which Resulted in Partial Fuel Starvation.Nipple Replaced & Old Nipple Reanalyzed + (ML19259C102)
- ML19259C103 + (ML19259C103)
- 05000250/LER-1979-016, Forwards LER 79-016/03L-0 + (ML19259C104)
- ML19259C105 + (ML19259C105)
- ML19259C106 + (ML19259C106)
- 05000245/LER-1979-013, Forwards LER 79-013/03L-0 + (ML19259C107)
- ML19259C109 + (ML19259C109)
- 05000245/LER-1979-013-03, /03L-0 on 790508:oxygen Pressure 603.5 Check for Source Range Monitors Not Completed for 24-h Period. Surveillance Overlooked.Checklist Added to Indicate Requirement of Procedure + (ML19259C110)
- 05000250/LER-1979-016-03, /03L-0 on 790429:high Level Alarm Annunciated. Caused by Instrument Drift of Tech Spec Min & High Level Alarms & Digital Level Indicator Transducer.Instruments Recalibr + (ML19259C111)