s,-

~^ '

(h*j li n BALTIMORE GAS AN D ELECTRIC COMPANY gas Atto CLECvRtc SusLDING DALTIMORC, M ARYLAND 242O3 April 2h,1979 an c. tu~~.a m,..

See Office of Inspection and Daforcenent, Region I ti. S. Nuclear Hegula*ory Crwr isalon 631 Park Avenue King of Prussia, PA 19L06 Attn:

Mr. Boyce H. Crier. Director

Subject:

Csivert Cliffs Nuclear Power Plant Unita Nos. 1 & 2. Dockets ?:os. 50--317 & 50-316 IE Bulletin 79-07 Scienic Stress Analysis of Safety Helated Pipinst Centlemen:

Following are our responses to questions posed by IE Bulletin 79-07 concerning seismic stress an=1ysis of safety related piping.

1)

None of the methods specified were used in the design of Calvert Cliffs piping.

2)

Not applicable.

3)

Consputer codes and verification. methods used in seismic stress analysis

~

of safety related piping are:

Code Description Verification Code a) ME 632

" Seismic Analysis of Piping Systems" PISOL, PIPSD TPIP!

Bechtel Power Corporation b) ME 101

" LEAP"

" Linear Elastic Analysis of ME 632. TPIPE, Pipe" Bechtel Power Corporation SUPERPIPE c)

PISOL EDS thaclear Inc.

EUPIPE, PIPESD. ADL1 ME 101 d)

SAPIPE PMB Systema Engineering Inc.

PISOL e)

TPIPE PMB Systems Engineering Inc.

PISOL, ME 632 f)

ALDPIPE Teledyne Engineering Service TMRSAP

'Jhe six coerponents of force or co sent (Fx, Py, Fz, Mx, Pte, Mr.) at various sections of the,rmtetor coolant svsta-i m_in loon ninine and the nressur-izer surge line nivine were computed separately for each of two 2284 213

% 3 ;a$1,-

7906120286 oo o

\\

.n

,y..

Page 2 horizontal and the vertical directions of seismic excitations by response spectru:s dynamic analysis.

The codirectional ccmponents of force or marament from one horizontal and the vertical directions of' excitation were combined by absolute sumation to define the seismic loading condition at the particular niping location for one horizontal and the vertical excitations.

A second seismic loading condition was also defined by repeating the absolute sum conbination for the other horizontal and the vertical excitations.

Each load set was compared to. and shown to be less r,overning than, the seismic loadings specified for design of the piping.

The load combinations were calculated and verified by hand.

k)

Not applicshle.

~

Yery t s,

wJ.rqL,

~'

1 s.

7 cc:

Office of Inspection & Enforcement U. S. Nuclear Regulatory Cc==sission Washington, D. C.

20555 Atta:

Director Division of Reactor Operations Inspection 1

J. A. Biddison, Escuire G. F. *frowbrido. Esquire Messrs. E. L. Conner, Jr. - NRC J. W. Brothers - Bechtel P. W. Kruse - CE 2284 214 p g Q"D [ Nk