- 05000260/LER-1979-008-01, /01T-0 on 790504:while Preparing for Refueling Outage,Secondary Containment Integrity Was Not Conclusively Demonstrated Prior to Breaking Primary Containment.Test Improperly Performed Due to Personnel Error + (ML18024A811)
- 05000260/LER-1979-007, Forwards LER 79-007/03L-0 + (ML18024A814)
- ML18024A815 + (ML18024A815)
- 05000260/LER-1979-007-03, /03L-0 on 790503:during Refueling Outage,Five MSIVs Exceeded Leakage Limits.Caused by Irregularities on Valve Seating Surfaces & Entrapment of Debris Under Seating Surfaces.Valves Will Be Repaired & Retested + (ML18024A816)
- ML18024A818 + (ML18024A818)
- ML18024A819 + (ML18024A819)
- ML18024A823 + (ML18024A823)
- 05000260/LER-1979-006, Forwards LER 79-006/03L-0 + (ML18024A824)
- ML18024A825 + (ML18024A825)
- 05000260/LER-1979-006-03, /03L-0 on 790427:prior to Refueling Shutdown, Drywell Prepurge Tritium Sample Not Taken.Caused by Lack of Understanding Between Operational & Lab Personnel.Operating Instructions Amended to Prevent Recurrence + (ML18024A826)
- ML18024A827 + (ML18024A827)
- ML18024A828 + (ML18024A828)
- 05000260/LER-1979-011, Forwards LER 79-011/01T-0 + (ML18024A829)
- ML18024A830 + (ML18024A830)
- ML18024A831 + (ML18024A831)
- 05000260/LER-1979-011-01, /01T-0 on 790526:while Pulling Control Rods,First Rod 26-27 in Group 3 Was Inadvertently Withdrawn Three Notches.Caused by Unexplained Factors.Procedures Were Revised + (ML18024A832)
- ML18024A833 + (ML18024A833)
- ML18024A834 + (ML18024A834)
- 05000296/LER-1979-006, Forwards LER 79-006/03L-0 + (ML18024A836)
- ML18024A837 + (ML18024A837)
- 05000260/LER-1979-009, Forwards LER 79-009/03L-0 + (ML18024A840)
- ML18024A841 + (ML18024A841)
- 05000260/LER-1979-009-03, /03L-0 on 790510:scram Accumulator Level Switch LS-2-85-34 for Control Rod Drivelines 58-39 & 58-19 Failed to Give Annunciation for High Accumulator Level.Caused by Switch Failure + (ML18024A842)
- 05000260/LER-1979-010, Forwards LER 79-010/03L-0 + (ML18024A843)
- ML18024A844 + (ML18024A844)
- 05000260/LER-1979-010-03, /03L-0 on 790510:residual Heat Removal Sys Snubber Came Apart Upon Removal for Testing.Caused by Piston Unscrewing from Rod After Locking Key Vibrated Loose.Snubber Replaced & Other Snubber Tested + (ML18024A845)
- IR 05000260/1979011 + (ML18024A847)
- ML18024A847 + (ML18024A847)
- ML18024A848 + (ML18024A848)
- ML18024A849 + (ML18024A849)
- ML18024A850 + (ML18024A850)
- IR 05000259/1979008 + (ML18024A851)
- ML18024A856 + (ML18024A856)
- ML18024A857 + (ML18024A857)
- ML18024A858 + (ML18024A858)
- ML18024A860 + (ML18024A860)
- ML18024A861 + (ML18024A861)
- 05000260/LER-1979-012, Forwards LER 79-012/03L-0 + (ML18024A862)
- ML18024A863 + (ML18024A863)
- 05000260/LER-1979-012-03, /03L-0 on 790528:during post-refueling Startup Testing of RCIC Turbine, Electronic Overspeed Device Could Not Be Reset.Caused by Failure of Electronic Overspeed Device,Airpax Model FSS 406.Overspeed Device Replaced + (ML18024A864)
- ML18024A867 + (ML18024A867)
- 05000260/LER-1979-014-01, /01T-0 on 790526:during Cold Shutdown for Refueling,Local Leak Rate Was Found to Exceed Tech Spec Levels.Caused by Deterioration of Valve Seats in Main Steam, Ventilation, Feedwater & RCIC Sys.Valves Repaired + (ML18024A868)
- ML18024A870 + (ML18024A870)
- ML18024A874 + (ML18024A874)
- ML18024A875 + (ML18024A875)
- ML18024A876 + (ML18024A876)
- ML18024A877 + (ML18024A877)
- 05000260/LER-1979-016, Forwards LER 79-016/03L-0 + (ML18024A878)
- ML18024A879 + (ML18024A879)
- 05000260/LER-1979-016-03, /03L-0 on 790605:pressure Switches PS-1-81A & B & Setpoints PS-1-91A & B Exceeded Tech Spec Limits During Test.Caused by Instrument Drift.Switches Recalibr & Tested Satisfactorily + (ML18024A880)