L-92-203, Special Rept:Three Surveillance Tendons,Inspected on 920612, 19 & 29 Found W/Measured Normalized lift-off Force Below Predicted Lower limit.Lift-off Forces Restored to Required Level of Integrity.Addl Rept Will Be Sent by 920915 +, L-92-262, Provides Rept Summarizing Surveillance Testing of Hoops Tendons Inspected During Unit 3 Twentieth Yr Insp,Per 920805 Commitment +, L-92-344 +, L-95-05 +, L-95-050, Technical Evaluation Rept on Second 10-Yr Interval ISI Program Plan:Sce,San Onofre Nuclear Generating Station, Units 2 & 3,Docket Numbers 50-361 & 50-362 +, L-93-002, Advises That Draft Decommissioning Funding Plan Presently in Final Stages of Internal Review & Expected to Be Completed within Next Few Wks.Plan Originally Expected to Be Submitted on or Before 921231,per Licensee +, L-93-174, Forwards Addl Info on Results of 20th Yr Tendon Surveillance,In Response to NRC 930125 Rai,Per 930111 Meeting W/Nrc Re 20th Yr Tendon Surveillance Program for Turkey Point Units 3 & 4 +, L-93-133, Application for Amends to Licenses DPR-31 & DPR-41,modifying TS 5.2.2, Design Pressure & Temp & Associated Bases to Correct Ref to Max Containment Design Internal Pressure from 59 Psig to 55 Psig +, L-92-330, Special Rept:On 921106 & 12,20th Yr Tendon Insp Determined That lift-off Value for Hoop Tendon 13H54 & Dome Tendon 1D40 Below Min Design Prestress Force.Tendons Restored to Required Level.Addl Rept to Be Submitted by 930129 +  and L-92-223, Special Rept:On 920706,hoop Tendon Group Found to Have Measured Normalized lift-off Force Below Predicted Lower Limit.Cause Under investigation.Lift-off Forces in Tendons 42H31,42H32 & 42H33 Restored to Required Level +
05000250  +, 05000251  +  and 00250  +
January 11, 1995  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
February 20, 1995  +
L
L-92-203, Special Rept:Three Surveillance Tendons,Inspected on 920612, 19 & 29 Found W/Measured Normalized lift-off Force Below Predicted Lower limit.Lift-off Forces Restored to Required Level of Integrity.Addl Rept Will Be Sent by 920915 +, L-92-262, Provides Rept Summarizing Surveillance Testing of Hoops Tendons Inspected During Unit 3 Twentieth Yr Insp,Per 920805 Commitment +, L-92-344 +, L-95-05 +, L-95-050, Technical Evaluation Rept on Second 10-Yr Interval ISI Program Plan:Sce,San Onofre Nuclear Generating Station, Units 2 & 3,Docket Numbers 50-361 & 50-362 +, L-93-002, Advises That Draft Decommissioning Funding Plan Presently in Final Stages of Internal Review & Expected to Be Completed within Next Few Wks.Plan Originally Expected to Be Submitted on or Before 921231,per Licensee +, L-93-174, Forwards Addl Info on Results of 20th Yr Tendon Surveillance,In Response to NRC 930125 Rai,Per 930111 Meeting W/Nrc Re 20th Yr Tendon Surveillance Program for Turkey Point Units 3 & 4 +, L-93-133, Application for Amends to Licenses DPR-31 & DPR-41,modifying TS 5.2.2, Design Pressure & Temp & Associated Bases to Correct Ref to Max Containment Design Internal Pressure from 59 Psig to 55 Psig +, L-92-330, Special Rept:On 921106 & 12,20th Yr Tendon Insp Determined That lift-off Value for Hoop Tendon 13H54 & Dome Tendon 1D40 Below Min Design Prestress Force.Tendons Restored to Required Level.Addl Rept to Be Submitted by 930129 +  and L-92-223, Special Rept:On 920706,hoop Tendon Group Found to Have Measured Normalized lift-off Force Below Predicted Lower Limit.Cause Under investigation.Lift-off Forces in Tendons 42H31,42H32 & 42H33 Restored to Required Level +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
13:49:43, 7 January 2025  +
Processing error"Processing error" is a predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> and represents errors that appeared in connection with improper value annotations or input processing.
Request  +
5H-7 +, 5H-1 +, 5H-2 +, 5H-3 +, 5H-4 +, 5H-5 +, 5H-6 +, 5H-9 +, 5H-11 +, 5H-12 +, 5H-1A +, 5H-1B +, 5H-14 +, 5H-15 +, 5H-17 +, 07-94-820 +  and 5H-18 +
February 20, 1995  +
Engineering Evaluation of Turkey Point Units 3 & 4 Containment Structures  +