The following information was provided by … The following information was provided by Southern Nuclear Operating Company via email:</br>This is a non-emergency notification required by 10 CFR 21.21(d)(3)(i). A written report in accordance with 10 CFR 21.21(d)(3)(ii) will be provided within 30 days.</br>Based upon the information provided by Operation Technology, Inc. (OTI) in (electrical transient analyzer program) (ETAP) error report ERCA-24-003, revision 1, Southern Nuclear Operating Company (SNC) has determined that a substantial safety hazard could have been created by the error introduced in the transient stability program in the current release of ETAP software utilized at Edwin I. Hatch Nuclear Plant (HNP) and Vogtle Electric Generating Plant Units 1 and 2 (VEGP1-2) were it to go uncorrected. While the nature of the software error detailed by OTI in ETAP error report ERCA-24-003, revision 1 had the potential to impact bus transfers and degrade essential safety-related equipment, SNC has verified that none of the HNP or VEGP1-2 calculations that utilized the transient stability program had false favorable results.</br>The NRC Senior Residents at HNP and VEGP1-2 have been notified.</br>Affected plants:</br>Hatch Nuclear Plant Units 1 and 2</br>Vogtle Electric Generating Plant Units 1 and 2le Electric Generating Plant Units 1 and 2 +
05:00:00, 26 March 2025 +
17:49:00, 26 March 2025 +
05:00:00, 26 March 2025 +
The following information was provided by … The following information was provided by Southern Nuclear Operating Company via email:</br>This is a non-emergency notification required by 10 CFR 21.21(d)(3)(i). A written report in accordance with 10 CFR 21.21(d)(3)(ii) will be provided within 30 days.</br>Based upon the information provided by Operation Technology, Inc. (OTI) in (electrical transient analyzer program) (ETAP) error report ERCA-24-003, revision 1, Southern Nuclear Operating Company (SNC) has determined that a substantial safety hazard could have been created by the error introduced in the transient stability program in the current release of ETAP software utilized at Edwin I. Hatch Nuclear Plant (HNP) and Vogtle Electric Generating Plant Units 1 and 2 (VEGP1-2) were it to go uncorrected. While the nature of the software error detailed by OTI in ETAP error report ERCA-24-003, revision 1 had the potential to impact bus transfers and degrade essential safety-related equipment, SNC has verified that none of the HNP or VEGP1-2 calculations that utilized the transient stability program had false favorable results.</br>The NRC Senior Residents at HNP and VEGP1-2 have been notified.</br>Affected plants:</br>Hatch Nuclear Plant Units 1 and 2</br>Vogtle Electric Generating Plant Units 1 and 2le Electric Generating Plant Units 1 and 2 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 26 March 2025 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
11:20:07, 28 March 2025 +
17:49:00, 26 March 2025 +
0.534 d (12.82 hours, 0.0763 weeks, 0.0176 months) +
05:00:00, 26 March 2025 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.