The following information was received fro … The following information was received from the Commonwealth of Kentucky via email:</br>Hardin Memorial Hospital (HMH) reported that a patient only received 106 mCi of I-131, instead of the prescribed 150 mCi post-thyroidectomy on 2/16/17. Two capsules of I-131 were received from the radiopharmacy in a single vial. When the technologist gave the patient the vial, the patient shook the contents of the vial into her mouth only swallowing one capsule. The tech did not see one capsule remained in the vial. Surveys on the package (containing the vial) that was to be sent back to the radiopharmacy were higher than background so (it) was held for decay. Another survey on 2/28/17 was taken and was still higher than background so the tech opened the package and discovered the remaining pill.</br>Kentucky Event Report ID No.: KY170002</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
05:00:00, 16 February 2017 +
52,611 +
17:35:00, 14 March 2017 +
05:00:00, 16 February 2017 +
The following information was received fro … The following information was received from the Commonwealth of Kentucky via email:</br>Hardin Memorial Hospital (HMH) reported that a patient only received 106 mCi of I-131, instead of the prescribed 150 mCi post-thyroidectomy on 2/16/17. Two capsules of I-131 were received from the radiopharmacy in a single vial. When the technologist gave the patient the vial, the patient shook the contents of the vial into her mouth only swallowing one capsule. The tech did not see one capsule remained in the vial. Surveys on the package (containing the vial) that was to be sent back to the radiopharmacy were higher than background so (it) was held for decay. Another survey on 2/28/17 was taken and was still higher than background so the tech opened the package and discovered the remaining pill.</br>Kentucky Event Report ID No.: KY170002</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 14 March 2017 +
202-029-22 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
01:43:07, 2 March 2018 +
17:35:00, 14 March 2017 +
26.566 d (637.58 hours, 3.795 weeks, 0.873 months) +
05:00:00, 16 February 2017 +