Browse wiki
Jump to navigation
Jump to search
The following information is a synopsis of … The following information is a synopsis of information received via E-mail:</br>During refurbishment of General Electric AK-25 type circuit breakers (P/N's: AK-2A-25-1, AK-3A-25-1, and AK-7A-25-1) by United Controls International (UCI), non-current carrying/non-copper based components of the upper stud assembly were silver plated. Bubbling of the silver plating was later noted which is an indication that the plating material was not adhering to the base metal. Flaking of the silver plating material may occur and may introduce conductive foreign material into the host circuit breaker. Introduction of this conductive material could create the possibility of a short circuit of the current sensor terminal board for circuit breakers configured with RMS-9 trip units and subsequent failure of the circuit breaker.</br>Fort Calhoun Nuclear Station is the only known recipient of affected breakers. Fort Calhoun received 18 breakers that contained improperly silver plated components. 14 of these 18 circuit breakers have been returned to UCI. Four of the 18 circuit breakers have been installed at Fort Calhoun and UCI is currently awaiting the return of these four circuit breakers.the return of these four circuit breakers. +
05:00:00, 12 October 2015 +
14:53:00, 1 December 2015 +
05:00:00, 12 October 2015 +
The following information is a synopsis of … The following information is a synopsis of information received via E-mail:</br>During refurbishment of General Electric AK-25 type circuit breakers (P/N's: AK-2A-25-1, AK-3A-25-1, and AK-7A-25-1) by United Controls International (UCI), non-current carrying/non-copper based components of the upper stud assembly were silver plated. Bubbling of the silver plating was later noted which is an indication that the plating material was not adhering to the base metal. Flaking of the silver plating material may occur and may introduce conductive foreign material into the host circuit breaker. Introduction of this conductive material could create the possibility of a short circuit of the current sensor terminal board for circuit breakers configured with RMS-9 trip units and subsequent failure of the circuit breaker.</br>Fort Calhoun Nuclear Station is the only known recipient of affected breakers. Fort Calhoun received 18 breakers that contained improperly silver plated components. 14 of these 18 circuit breakers have been returned to UCI. Four of the 18 circuit breakers have been installed at Fort Calhoun and UCI is currently awaiting the return of these four circuit breakers.the return of these four circuit breakers. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 1 December 2015 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
01:46:14, 2 March 2018 +
14:53:00, 1 December 2015 +
50.37 d (1,208.88 hours, 7.196 weeks, 1.656 months) +
05:00:00, 12 October 2015 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.