This is an 8-hour notification being made This is an 8-hour notification being made in accordance with 10CFR 50.72(b)(3)(ii)(B) for an event or condition that results in the plant being in an unanalyzed condition that significantly degrades plant safety.</br>This notification is being made as the result of the re-review of a July 7, 2008 occurrence which resulted in an inadvertent isolation of a large portion of the (fire suppression) ring header affecting all Unit 2 fire suppression and a portion of Unit 1 fire suppression. The Unit 1 ring header isolation did not have an affect on the fire safe shutdown capability of Unit 1. However, three areas in Unit 2 which credit the availability of fire suppression to assure that the safe shutdown capability could have been achieved did not have fire suppression for approximately 3 hours.</br>A Licensee Event Report will be submitted within 60 days.</br>The licensee notified the NRC Resident Inspector.ensee notified the NRC Resident Inspector.  +
03:47:00, 8 July 2008  +
45,631  +
17:59:00, 14 January 2010  +
03:47:00, 8 July 2008  +
This is an 8-hour notification being made This is an 8-hour notification being made in accordance with 10CFR 50.72(b)(3)(ii)(B) for an event or condition that results in the plant being in an unanalyzed condition that significantly degrades plant safety.</br>This notification is being made as the result of the re-review of a July 7, 2008 occurrence which resulted in an inadvertent isolation of a large portion of the (fire suppression) ring header affecting all Unit 2 fire suppression and a portion of Unit 1 fire suppression. The Unit 1 ring header isolation did not have an affect on the fire safe shutdown capability of Unit 1. However, three areas in Unit 2 which credit the availability of fire suppression to assure that the safe shutdown capability could have been achieved did not have fire suppression for approximately 3 hours.</br>A Licensee Event Report will be submitted within 60 days.</br>The licensee notified the NRC Resident Inspector.ensee notified the NRC Resident Inspector.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
3.472222e-5 d (8.333333e-4 hours, 4.960317e-6 weeks, 1.1415e-6 months)  +
00:00:00, 14 January 2010  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:10:29, 2 March 2018  +
17:59:00, 14 January 2010  +
false  +
false  +
555.55 d (13,333.2 hours, 79.364 weeks, 18.264 months)  +
03:47:00, 8 July 2008  +
Loss of Fire Suppression Capability  +