The following information was obtained froThe following information was obtained from the licensee via facsimile:</br>On October 29, 2004, at approximately 1600 hours, control room operators were informed by engineering personnel that raceways were located closer than 20 feet from the redundant division without being protected by a fire barrier wrap in accordance with the requirements of 10CFR50 Appendix R, Section III.G.2.</br>In 480 volt switchgear room E7, Brunswick is committed to maintaining redundant safe shutdown circuits by a minimum of 20 feet with no-intervening combustibles, unless the circuits are protected by a one-hour fire barrier wrap. Two conduits containing Division II circuits were identified closer than 20 feet to their redundant counterparts with no wrap installed.</br>The (NRC) Resident Inspector has been notified.</br>INITIAL SAFETY SIGNIFICANCE EVALUATION</br>The initial safety significance of this condition is considered to be minimal. When the condition was recognized, impairments were established in accordance with the fire protection program and compensatory measures were implemented. In addition, fire detection systems in the affected area have been verified to be operable. The affected area is maintained as a combustible free separation zone.</br>CORRECTIVE ACTIONS</br>Impairments have been initiated and appropriate compensatory measures established. The root cause and additional corrective actions are being documented in accordance with the corrective action program.rdance with the corrective action program.  +
20:00:00, 29 October 2004  +
41,160  +
16:25:00, 29 October 2004  +
20:00:00, 29 October 2004  +
The following information was obtained froThe following information was obtained from the licensee via facsimile:</br>On October 29, 2004, at approximately 1600 hours, control room operators were informed by engineering personnel that raceways were located closer than 20 feet from the redundant division without being protected by a fire barrier wrap in accordance with the requirements of 10CFR50 Appendix R, Section III.G.2.</br>In 480 volt switchgear room E7, Brunswick is committed to maintaining redundant safe shutdown circuits by a minimum of 20 feet with no-intervening combustibles, unless the circuits are protected by a one-hour fire barrier wrap. Two conduits containing Division II circuits were identified closer than 20 feet to their redundant counterparts with no wrap installed.</br>The (NRC) Resident Inspector has been notified.</br>INITIAL SAFETY SIGNIFICANCE EVALUATION</br>The initial safety significance of this condition is considered to be minimal. When the condition was recognized, impairments were established in accordance with the fire protection program and compensatory measures were implemented. In addition, fire detection systems in the affected area have been verified to be operable. The affected area is maintained as a combustible free separation zone.</br>CORRECTIVE ACTIONS</br>Impairments have been initiated and appropriate compensatory measures established. The root cause and additional corrective actions are being documented in accordance with the corrective action program.rdance with the corrective action program.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
0.0185 d (0.444 hours, 0.00265 weeks, 6.088e-4 months)  +
00:00:00, 29 October 2004  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:22:26, 2 March 2018  +
16:25:00, 29 October 2004  +
false  +
-0.149 d (-3.58 hours, -0.0213 weeks, -0.0049 months)  +
20:00:00, 29 October 2004  +
Unanalyzed Condition Discovered in 480 Volt Switchgear Room  +