During performance of a weekly preventive … During performance of a weekly preventive maintenance activity, (it was) discovered that the discharge dampers of Emergency Diesel Generator 102 Exhaust Fans opened approximately one inch vice full open as expected. Technical Specification 3.6.3e 14 day shutdown LCO was entered at 13:40. At 1350, Technical Specification 3.6.3e(1) was entered due to as found condition of both ventilation exhaust dampers for Emergency Diesel Generators 102 and 103 covered with snow and ice preventing normal operation of dampers. This condition required an initiation of normal orderly shutdown in one hour and the Reactor in cold shutdown condition within ten hours. At 14:10, Emergency Diesel Generators 102 and 103 were declared operable based on snow/ice removal and satisfactory completion of testing on all fans and dampers.</br>The Licensee notified the NRC Resident Inspector. </br>***** Event Retracted. From Hicks to Taylor on 3/4/04 at 1020 EST*****</br>This Event Notification is being made to rescind previous Event Notification made on 2/05/2004. The notification was made as an eight hour report per 10 CFR50.72 (b)(3)(v)(D) and an LER IAW 10CFR50.73(a)(2)(v)(D) and (vi).</br>Subsequent Engineering evaluation has concluded that the Emergency Diesel Generators (EDGs), and more specifically their Room Ventilation Fans (Support System) would have performed their design function.</br>The specific event described a snow and ice condition that impeded the Ventilation Fan Dampers from fully opening. The dampers did however, partially open. Engineering has concluded that although there was reduced ventilation flow through the dampers, the air flow rate through the reduced exhaust fan opening would have melted the snow and ice. The melting would have occurred at a progressively faster rate (as the exhaust flow rate and room air temperature both increased) and eventually provided adequate ventilation flow to maintain normal room temperature.</br>Notified R1DO (Todd Jackson).temperature.
Notified R1DO (Todd Jackson). +
18:40:00, 5 February 2004 +
40,506 +
15:45:00, 5 February 2004 +
18:40:00, 5 February 2004 +
During performance of a weekly preventive … During performance of a weekly preventive maintenance activity, (it was) discovered that the discharge dampers of Emergency Diesel Generator 102 Exhaust Fans opened approximately one inch vice full open as expected. Technical Specification 3.6.3e 14 day shutdown LCO was entered at 13:40. At 1350, Technical Specification 3.6.3e(1) was entered due to as found condition of both ventilation exhaust dampers for Emergency Diesel Generators 102 and 103 covered with snow and ice preventing normal operation of dampers. This condition required an initiation of normal orderly shutdown in one hour and the Reactor in cold shutdown condition within ten hours. At 14:10, Emergency Diesel Generators 102 and 103 were declared operable based on snow/ice removal and satisfactory completion of testing on all fans and dampers.</br>The Licensee notified the NRC Resident Inspector. </br>***** Event Retracted. From Hicks to Taylor on 3/4/04 at 1020 EST*****</br>This Event Notification is being made to rescind previous Event Notification made on 2/05/2004. The notification was made as an eight hour report per 10 CFR50.72 (b)(3)(v)(D) and an LER IAW 10CFR50.73(a)(2)(v)(D) and (vi).</br>Subsequent Engineering evaluation has concluded that the Emergency Diesel Generators (EDGs), and more specifically their Room Ventilation Fans (Support System) would have performed their design function.</br>The specific event described a snow and ice condition that impeded the Ventilation Fan Dampers from fully opening. The dampers did however, partially open. Engineering has concluded that although there was reduced ventilation flow through the dampers, the air flow rate through the reduced exhaust fan opening would have melted the snow and ice. The melting would have occurred at a progressively faster rate (as the exhaust flow rate and room air temperature both increased) and eventually provided adequate ventilation flow to maintain normal room temperature.</br>Notified R1DO (Todd Jackson).temperature.
Notified R1DO (Todd Jackson). +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100 +
00:00:00, 4 March 2004 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:24:03, 2 March 2018 +
15:45:00, 5 February 2004 +
true +
false +
-0.122 d (-2.92 hours, -0.0174 weeks, -0.004 months) +
18:40:00, 5 February 2004 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.