Browse wiki

Jump to navigation Jump to search
The following information is a summary of The following information is a summary of information provided by the Arkansas Department of Health (the Department) via email:</br>During routine gauge shutter checks conducted by the licensee on October 2, 2025, the licensee found the shutters of three Berthold Technologies model LB300L fixed gauges stuck in the open position. The licensee has flagged the gauges, placed barriers around the gauges, and suspended any work in the area. The licensee is arranging for a Berthold field representative to perform maintenance on the gauges to attempt to close the gauges.</br>Gauge 1: 0.2 mCi Co-60</br>Gauge 2: 0.5 mCi Co-60</br>Gauge 3: 1.8 mCi Co-60</br>Arkansas event: AR-2025-013</br>* * * UPDATE ON 10/20/2025 AT 1617 EDT FROM HUNTER BROADAWAY TO JOSUE RAMIREZ * * *</br>The following information is a summary of information provided by the Arkansas Department of Health (the Department) via email:</br>On October 20, 2025, a response from DOMTAR A.W. LLC, Arkansas Licensee ARK-0354-03120, reports that under the direction of a Berthold Technologies representative, the three shutters were able to be cycled and are once again functional. Maintenance and leak testing were performed on the three gauges. </br>Arkansas event AR-2025-013 is considered closed by the Department.13 is considered closed by the Department.  +
05:00:00, 2 October 2025  +
57,965  +
13:56:00, 3 October 2025  +
05:00:00, 2 October 2025  +
The following information is a summary of The following information is a summary of information provided by the Arkansas Department of Health (the Department) via email:</br>During routine gauge shutter checks conducted by the licensee on October 2, 2025, the licensee found the shutters of three Berthold Technologies model LB300L fixed gauges stuck in the open position. The licensee has flagged the gauges, placed barriers around the gauges, and suspended any work in the area. The licensee is arranging for a Berthold field representative to perform maintenance on the gauges to attempt to close the gauges.</br>Gauge 1: 0.2 mCi Co-60</br>Gauge 2: 0.5 mCi Co-60</br>Gauge 3: 1.8 mCi Co-60</br>Arkansas event: AR-2025-013</br>* * * UPDATE ON 10/20/2025 AT 1617 EDT FROM HUNTER BROADAWAY TO JOSUE RAMIREZ * * *</br>The following information is a summary of information provided by the Arkansas Department of Health (the Department) via email:</br>On October 20, 2025, a response from DOMTAR A.W. LLC, Arkansas Licensee ARK-0354-03120, reports that under the direction of a Berthold Technologies representative, the three shutters were able to be cycled and are once again functional. Maintenance and leak testing were performed on the three gauges. </br>Arkansas event AR-2025-013 is considered closed by the Department.13 is considered closed by the Department.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 20 October 2025  +
ARK-0354-03120  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
11:20:04, 21 October 2025  +
13:56:00, 3 October 2025  +
1.372 d (32.93 hours, 0.196 weeks, 0.0451 months)  +
05:00:00, 2 October 2025  +
Stuck Open Gauge Shutter  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.