Browse wiki

Jump to navigation Jump to search
The following information was provided by The following information was provided by the licensee via phone and email:</br>This 60-day telephone notification is being submitted in accordance with 10 CFR 50.73(a)(1) and 50.73(a)(2)(iv)(A). The event was an invalid actuation of the Unit 1 containment ventilation isolation (CVI) system.</br>On August 3, 2024, at 0840 EDT, with Unit 1 at 100 percent power, train 'A' of the CVI system actuated due to an invalid signal from 1-RM-90-130, containment purge air exhaust monitor. 1-RM-90-130 was out of service for maintenance testing at the time of the invalid signal. The cause of the signal was determined to be the result of an installed multimeter timing out, creating a short in the actuation circuitry. The train 'A' CVI signal was a full actuation of that train and the system functioned as designed.</br>Prior to and following the CVI alarm, all other radiation monitors were stable at their normal values; therefore, the CVI (actuation) was invalid. Control room operators performed appropriate checks and confirmed that all required automatic actuations occurred as designed. Subsequent completion of the maintenance instruction was successful. This event was entered into the corrective action program as CR 1948103.</br>The NRC Resident Inspector was notified.. The NRC Resident Inspector was notified.  +
12:40:00, 3 August 2024  +
08:28:00, 10 September 2024  +
12:40:00, 3 August 2024  +
The following information was provided by The following information was provided by the licensee via phone and email:</br>This 60-day telephone notification is being submitted in accordance with 10 CFR 50.73(a)(1) and 50.73(a)(2)(iv)(A). The event was an invalid actuation of the Unit 1 containment ventilation isolation (CVI) system.</br>On August 3, 2024, at 0840 EDT, with Unit 1 at 100 percent power, train 'A' of the CVI system actuated due to an invalid signal from 1-RM-90-130, containment purge air exhaust monitor. 1-RM-90-130 was out of service for maintenance testing at the time of the invalid signal. The cause of the signal was determined to be the result of an installed multimeter timing out, creating a short in the actuation circuitry. The train 'A' CVI signal was a full actuation of that train and the system functioned as designed.</br>Prior to and following the CVI alarm, all other radiation monitors were stable at their normal values; therefore, the CVI (actuation) was invalid. Control room operators performed appropriate checks and confirmed that all required automatic actuations occurred as designed. Subsequent completion of the maintenance instruction was successful. This event was entered into the corrective action program as CR 1948103.</br>The NRC Resident Inspector was notified.. The NRC Resident Inspector was notified.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 10 September 2024  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
11:20:11, 12 September 2024  +
08:28:00, 10 September 2024  +
false  +
37.825 d (907.8 hours, 5.404 weeks, 1.244 months)  +
12:40:00, 3 August 2024  +
60-DAY Notification of Invalid Specified System Actuation  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.