Browse wiki

Jump to navigation Jump to search
The following information was received froThe following information was received from the Alabama Department of Public Health, Office of Radiation Control via email:</br>The Radiation Safety Officer for Georgia-Pacific of Pennington, Alabama notified the Alabama Office of Radiation Control that while performing routine six (6) month leak testing and shutter checks, one of their gauges had a shutter stuck in the open position. The manufacturer has been notified and a repair date is pending. Further information involving the gauge is forthcoming in the written report.</br>Alabama Event No: 21-14</br>* * * UPDATE FROM CASON COAN TO LLOYD DESOTELL AT 1358 EST ON 12/13/21 * * * </br>The license number and following gauge information was received via e-mail: </br>Gauge Manufacturer: Berthold</br>Model No.: PB 80</br>Serial No.: 1028/3-10-17</br>Source: Co-60 (3.081 mCi)</br>The damaged gauge was transferred off-site for disposal on 10/19/21.</br>The Alabama Department of Public Health, Office of Radiation Control considers this event closed.</br>Notified R1DO (Young) and NMSS Events Notification group via email. NMSS Events Notification group via email.  +
05:00:00, 30 April 2021  +
55,226  +
15:41:00, 30 April 2021  +
05:00:00, 30 April 2021  +
The following information was received froThe following information was received from the Alabama Department of Public Health, Office of Radiation Control via email:</br>The Radiation Safety Officer for Georgia-Pacific of Pennington, Alabama notified the Alabama Office of Radiation Control that while performing routine six (6) month leak testing and shutter checks, one of their gauges had a shutter stuck in the open position. The manufacturer has been notified and a repair date is pending. Further information involving the gauge is forthcoming in the written report.</br>Alabama Event No: 21-14</br>* * * UPDATE FROM CASON COAN TO LLOYD DESOTELL AT 1358 EST ON 12/13/21 * * * </br>The license number and following gauge information was received via e-mail: </br>Gauge Manufacturer: Berthold</br>Model No.: PB 80</br>Serial No.: 1028/3-10-17</br>Source: Co-60 (3.081 mCi)</br>The damaged gauge was transferred off-site for disposal on 10/19/21.</br>The Alabama Department of Public Health, Office of Radiation Control considers this event closed.</br>Notified R1DO (Young) and NMSS Events Notification group via email. NMSS Events Notification group via email.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 13 December 2021  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
12:30:03, 14 December 2021  +
15:41:00, 30 April 2021  +
0.445 d (10.68 hours, 0.0636 weeks, 0.0146 months)  +
05:00:00, 30 April 2021  +
Stuck Gauge Shutter  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.