Browse wiki
Jump to navigation
Jump to search
Based on video surveillance and radiation … Based on video surveillance and radiation readings, National Institute of Standards and Technology (NIST) has determined they violated Safety Limit 2.1 - greater than 450 degrees Celsius in a single fuel element. This event notification relates to Event Notification #55094, from 2/3/21.</br>* * * UPDATE ON 06 MAY 2021 AT 1104 EDT FROM TOM NEWTON TO LLOYD DESOTELL * * *</br>The following is a summary of an update notification received via telephone:</br>This notification was made per Technical Specification 6.7.2</br>The investigation related to the February 3, 2021 NIST event (EN 55094) found administrative and procedural inadequacies including:</br>The fuel element was unlatched prior to reactor start up.</br>Inadequate training and proficiencies in latching of fuel. </br>Limiting Conditions for Operations 3.1.3 and 3.9.2.1 were not met.</br>Procedural compliance was not enforced.</br>Inadequate implementation of verification methods for latching fuel.</br>A written report will be submitted within 14 days.</br>Notified R1DO (Young), NRR EO (Miller), IR MOC (Gott), NRR PM (Montgomery), NRR PM (Torres), NPR ENC (Takacs), OPA (Burnell).(Torres), NPR ENC (Takacs), OPA (Burnell). +
12:33:00, 2 March 2021 +
07:33:00, 2 March 2021 +
12:33:00, 2 March 2021 +
Based on video surveillance and radiation … Based on video surveillance and radiation readings, National Institute of Standards and Technology (NIST) has determined they violated Safety Limit 2.1 - greater than 450 degrees Celsius in a single fuel element. This event notification relates to Event Notification #55094, from 2/3/21.</br>* * * UPDATE ON 06 MAY 2021 AT 1104 EDT FROM TOM NEWTON TO LLOYD DESOTELL * * *</br>The following is a summary of an update notification received via telephone:</br>This notification was made per Technical Specification 6.7.2</br>The investigation related to the February 3, 2021 NIST event (EN 55094) found administrative and procedural inadequacies including:</br>The fuel element was unlatched prior to reactor start up.</br>Inadequate training and proficiencies in latching of fuel. </br>Limiting Conditions for Operations 3.1.3 and 3.9.2.1 were not met.</br>Procedural compliance was not enforced.</br>Inadequate implementation of verification methods for latching fuel.</br>A written report will be submitted within 14 days.</br>Notified R1DO (Young), NRR EO (Miller), IR MOC (Gott), NRR PM (Montgomery), NRR PM (Torres), NPR ENC (Takacs), OPA (Burnell).(Torres), NPR ENC (Takacs), OPA (Burnell). +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 6 May 2021 +
TR-5 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
18:10:57, 30 August 2024 +
07:33:00, 2 March 2021 +
-0.208 d (-5 hours, -0.0298 weeks, -0.00685 months) +
12:33:00, 2 March 2021 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.