Based on video surveillance and radiation readings, National Institute of Standards and Technology (
NIST) has determined they violated Safety Limit 2.1 - greater than 450 degrees Celsius in a single fuel element. This event notification relates to
Event Notification#55094, from 2/3/21.
- * * UPDATE ON 06 MAY 2021 AT 1104 EDT FROM TOM NEWTON TO LLOYD DESOTELL * * *
The following is a summary of an update notification received via telephone:
This notification was made per Technical Specification 6.7.2
The investigation related to the February 3, 2021 NIST event (EN 55094) found administrative and procedural inadequacies including:
The fuel element was unlatched prior to reactor start up.
Inadequate training and proficiencies in latching of fuel.
Limiting Conditions for Operations 3.1.3 and 3.9.2.1 were not met.
Procedural compliance was not enforced.
Inadequate implementation of verification methods for latching fuel.
A written report will be submitted within 14 days.
Notified R1DO (Young),
NRR EO (Miller), IR
MOC (Gott),
NRR PM (Montgomery),
NRR PM (Torres),
NPR ENC (Takacs),
OPA (Burnell).