Browse wiki

Jump to navigation Jump to search
Heeled 30B UF6 Cylinders arrived at FramatHeeled 30B UF6 Cylinders arrived at Framatome at approximately 1235 (PDT) on September 12, 2019. The cylinders were inspected/surveyed for loose surface contamination at approximately 1335 (PDT). Two cylinders were identified to have greater than 24 dpm/cm2 alpha contamination limit and the 240 dpm/cm2 beta/gamma contamination limit set by DOT (Department of Transportation) and NRC. Each cylinder contained contamination on and around the valve cover. One cylinder contained 250 dpm/cm2 alpha and 2,500 dpm/cm2 beta/gamma, and another 35-40 dpm/cm2 alpha and 2,000 dpm/cm2 beta/gamma.</br>The top of the cylinders have been decontaminated and the valve covers have been removed and bagged.</br>(Title) 10 CFR 20.1906 requires immediate notification of the operations center and carrier in the event of contamination in excess of the limits specified in 49 CFR 173.443 during inspections required by 10 CFR 71.87.</br>There were no exposures to personnel and no contamination was found on the transport vehicle. The licensee is attempting to contact Westinghouse from where the cylinders originated.house from where the cylinders originated.  +
20:35:00, 12 September 2019  +
54,273  +
20:08:00, 12 September 2019  +
20:35:00, 12 September 2019  +
Heeled 30B UF6 Cylinders arrived at FramatHeeled 30B UF6 Cylinders arrived at Framatome at approximately 1235 (PDT) on September 12, 2019. The cylinders were inspected/surveyed for loose surface contamination at approximately 1335 (PDT). Two cylinders were identified to have greater than 24 dpm/cm2 alpha contamination limit and the 240 dpm/cm2 beta/gamma contamination limit set by DOT (Department of Transportation) and NRC. Each cylinder contained contamination on and around the valve cover. One cylinder contained 250 dpm/cm2 alpha and 2,500 dpm/cm2 beta/gamma, and another 35-40 dpm/cm2 alpha and 2,000 dpm/cm2 beta/gamma.</br>The top of the cylinders have been decontaminated and the valve covers have been removed and bagged.</br>(Title) 10 CFR 20.1906 requires immediate notification of the operations center and carrier in the event of contamination in excess of the limits specified in 49 CFR 173.443 during inspections required by 10 CFR 71.87.</br>There were no exposures to personnel and no contamination was found on the transport vehicle. The licensee is attempting to contact Westinghouse from where the cylinders originated.house from where the cylinders originated.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 12 September 2019  +
SNM-1227  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
12:30:08, 13 September 2019  +
20:08:00, 12 September 2019  +
Processing error"Processing error" is a predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> and represents errors that appeared in connection with improper value annotations or input processing.
-0.0188 d (-0.45 hours, -0.00268 weeks, -6.1641e-4 months)  +
20:35:00, 12 September 2019  +
Unplanned Surface Contamination  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.